A micro-CT evaluation of the performance of rotary and reciprocating single-file systems in shaping ability of curved root canals

被引:7
作者
Sousa-Neto, Manoel Damiao [1 ]
Crozeta, Bruno Monguilhott [1 ]
Lopes, Fabiane Carneiro [1 ]
Mazzi-Chaves, Jardel Francisco [1 ]
Pereira, Rodrigo Dantas [1 ]
Silva-Sousa, Alice Correa [1 ]
de Andrade Amaral, Mariana Carvalho [2 ]
Steier, Liviu [3 ]
Jacobs, Reinhilde [4 ]
Correa Silva-Sousa, Yara Teresinha [2 ]
机构
[1] Univ Sao Paulo, Sch Dent Ribeirao Preto, Dept Restorat Dent, Ribeirao Preto, SP, Brazil
[2] Univ Ribeirao Preto UNAERP, Fac Dent, Ribeirao Preto, SP, Brazil
[3] Univ Penn UPenn, Sch Dent Med, Philadelphia, PA USA
[4] Katholieke Univ Leuven KU Leuven, Fac Med, Dept Imaging & Pathol, Leuven, Belgium
来源
BRAZILIAN ORAL RESEARCH | 2020年 / 34卷
基金
巴西圣保罗研究基金会;
关键词
APICALLY EXTRUDED DEBRIS; GEOMETRY; INSTRUMENTATION; TRANSPORTATION; MORPHOLOGY; ONESHAPE;
D O I
10.1590/1807-3107bor-2020.vol34.0039
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
To compare the shaping ability of different single-file systems in the preparation of mesial curved canals of mandibular molars using micro-CT technology. Fifteen mesial roots of mandibular molars with two independent and curved canals (n = 30) were selected, scanned at a resolution of 26.7 mu m anatomically matched, and distributed into three groups (n = 10), according to the preparation system: WaveOne 25.08, Reciproc 25.08, and OneShape 25.06. A final micro-CT scanning was performed, data sets were registered with their respective counterparts, and compared regarding the three-dimensional (volume, surface area, and structure model index - SMI) and two-dimensional (perimeter, area, roundness, major and minor diameters) parameters, as well as, canal transportation, using ANOVA and post hoc Tukey tests (alpha = 5%). Overall, no difference was observed between groups regarding area, perimeter, volume, surface area, and canal transportation (p > 0.05). Within group, no canal transportation was significantly higherobserved in the apical third (0.10 +/- 0.05 mm) compared to coronal (0.08 +/- 0.040 mm) and middle (0.07 +/- 0.03 mm) thirds (p < 0.05). Structure model index (SMI) was statistically higher after preparation with OneShape instrument (0.36 +/- 0.26) compared to other systems (p < 0.05). Within the parameters of this study, similar shaping ability was observed in the preparation of mesial curved root canals of mandibular molars with Reciproc, OneShape and WaveOne systems.
引用
收藏
页数:9
相关论文
共 35 条
  • [2] THE ANTI-CURVATURE FILING METHOD TO PREPARE THE CURVED ROOT-CANAL
    ABOURASS, M
    FRANK, AL
    GLICK, DH
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1980, 101 (05) : 792 - 794
  • [3] Agarwal RS, 2015, J CLIN DIAGN RES, V9, pZC6, DOI [10.7860/JCDR/2015/12097.5863, 10.7860/JCDR/2015/14300.6236]
  • [4] Barbizam JVB, 2002, J ENDODONT, V28, P365
  • [5] Bürklein S, 2013, INT ENDOD J, V46, P590, DOI [10.1111/iej.12037, 10.1111/iej.12161]
  • [6] Apically Extruded Debris with Reciprocating Single-File and Full-sequence Rotary Instrumentation Systems
    Buerklein, Sebastian
    Schaefer, Edgar
    [J]. JOURNAL OF ENDODONTICS, 2012, 38 (06) : 850 - 852
  • [7] Comparative Study of Different Novel Nickel-Titanium Rotary Systems for Root Canal Preparation in Severely Curved Root Canals
    Capar, Ismail Davut
    Ertas, Huseyin
    Ok, Evren
    Arslan, Hakan
    Ertas, Elif Tarim
    [J]. JOURNAL OF ENDODONTICS, 2014, 40 (06) : 852 - 856
  • [8] Influence of Heat Treatment of Nickel-Titanium Rotary Endodontic Instruments on Apical Preparation: A Micro-Computed Tomographic Study
    de Almeida, Bernardo Correa
    Ormiga, Fabiola
    Pimenta de Araujo, Marcos Cesar
    Lopes, Ricardo Tadeu
    Barbosa Lima, Inaya Correa
    dos Santos, Bernardo Camargo
    Gusman, Heloisa
    [J]. JOURNAL OF ENDODONTICS, 2015, 41 (12) : 2031 - 2035
  • [9] Research that matters - root canal filling and leakage studies
    De-Deus, G.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2012, 45 (12) : 1063 - 1064
  • [10] Dhingra Anil, 2014, J Conserv Dent, V17, P138, DOI 10.4103/0972-0707.128049