Functional estimation of bony segment lengths using magneto-inertial sensing: Application to the humerus

被引:6
作者
Crabolu, Michele [1 ]
Pani, Danilo [1 ]
Raffo, Luigi [1 ]
Conti, Maurizio [2 ]
Cereatti, Andrea [3 ,4 ,5 ]
机构
[1] Univ Cagliari, Dept Elect & Elect Engn, Cagliari, Italy
[2] Univ Sassari, Dept Clin & Expt Med, Sassari, Italy
[3] Univ Sassari, Dept POLCOMING, Sassari, Italy
[4] Interuniv Ctr Bioengn Human Neuromusculoskeletal, Sassari, Italy
[5] Politecn Torino, Dept Elect & Telecommun, Turin, Italy
来源
PLOS ONE | 2018年 / 13卷 / 09期
关键词
COORDINATE SYSTEMS; JOINT CENTER; ROTATION; SHOULDER; ELBOW; POSITION;
D O I
10.1371/journal.pone.0203861
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Inertial sensor technology has assumed an increasingly important role in the field of human motion analysis. However, the reliability of the kinematic estimates could still be critical for specific applications in the field of functional evaluation and motor rehabilitation. Within this context, the definition of subject-specific multi-body kinematic models is crucial since it affects the accuracy and repeatability of movement reconstruction. A key step for kinematic model calibration is the determination of bony segment lengths. This study proposes a functional approach for the in vivo estimation of the humerus length using a single magneto-inertial measurement unit (MIMU) positioned on the right distal posterior forearm. The humerus length was estimated as the distance between the shoulder elevation axis and the elbow flexion-extension axis. The calibration exercise involved five shoulder elevations in the sagittal plane with the elbow completely extended and five elbow flexion-extensions with the upper arm rigidly aligned to the trunk. Validation of the method was conducted on five healthy subjects using the humerus length computed from magnetic resonance imaging as the gold standard. The method showed mean absolute errors of 12 +/- 9 mm, which were in the estimate of the humerus length. When using magneto-inertial technology, the proposed functional method represents a promising alternative to the regressive methods or manual measurements for performing kinematic model calibrations. Although the proposed methodology was validated for the estimation of the humerus length, the same approach can be potentially extended to other body segments.
引用
收藏
页数:11
相关论文
共 34 条
  • [1] BAGG SD, 1988, AM J PHYS MED REHAB, V67, P238
  • [2] Radiographic determinants of the elbow rotation axis: Experimental identification and quantitative validation
    Bottlang, M
    O'Rourke, MR
    Madey, SM
    Steyers, CM
    Marsh, JL
    Brown, TD
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2000, 18 (05) : 821 - 828
  • [3] Comparative evaluation of scapular and humeral coordinate systems based on biomedical images of the glenohumeral joint
    Calderone, Manuela
    Cereatti, Andrea
    Conti, Maurizio
    Della Croce, Ugo
    [J]. JOURNAL OF BIOMECHANICS, 2014, 47 (03) : 736 - 741
  • [4] GAIT ANALYSIS METHODOLOGY
    CAPPOZZO, A
    [J]. HUMAN MOVEMENT SCIENCE, 1984, 3 (1-2) : 27 - 50
  • [5] Standardization proposal of soft tissue artefact description for data sharing in human motion measurements
    Cereatti, Andrea
    Bonci, Tecla
    Akbarshahi, Massoud
    Aminian, Kamiar
    Barre, Arnaud
    Begon, Mickael
    Benoit, Daniel L.
    Charbonnier, Caecilia
    Dal Maso, Fabien
    Fantozzi, Silvia
    Lin, Cheng-Chung
    Lu, Tung-Wu
    Pandy, Marcus G.
    Stagni, Rita
    van den Bogert, Antonie J.
    Camomilla, Valentina
    [J]. JOURNAL OF BIOMECHANICS, 2017, 62 : 5 - 13
  • [6] In vivo glenohumeral translation under anterior loading in an open-MRI set-up
    Cereatti, Andrea
    Calderone, Manuela
    Buckland, Dan M.
    Buettner, Anne
    Della Croce, Ugo
    Rosso, Claudio
    [J]. JOURNAL OF BIOMECHANICS, 2014, 47 (15) : 3771 - 3775
  • [7] Inverse Kinematics for Upper Limb Compound Movement Estimation in Exoskeleton-Assisted Rehabilitation
    Cortes, Camilo
    de los Reyes-Guzman, Ana
    Scorza, Davide
    Bertelsen, Alvaro
    Carrasco, Eduardo
    Gil-Agudo, Angel
    Ruiz-Salguero, Oscar
    Florez, Julian
    [J]. BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [8] In vivo estimation of the shoulder joint center of rotation using magneto-inertial sensors: MRI-based accuracy and repeatability assessment
    Crabolu, M.
    Pani, D.
    Raffo, L.
    Conti, M.
    Crivelli, P.
    Cereatti, A.
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2017, 16
  • [9] Estimation of the center of rotation using wearable magneto-inertial sensors
    Crabolu, M.
    Pani, D.
    Raffo, L.
    Cereatti, A.
    [J]. JOURNAL OF BIOMECHANICS, 2016, 49 (16) : 3928 - 3933
  • [10] Adjustments to Zatsiorsky-Seluyanov's segment inertia parameters
    de Leva, P