A novel and independent method for time-resolved gantry angle quality assurance for VMAT

被引:3
作者
Fuangrod, Todsaporn [1 ]
Greer, Peter B. [1 ,2 ]
Zwan, Benjamin J. [2 ,3 ]
Barnes, Michael P. [1 ,2 ,4 ]
Lehmann, Joerg [1 ,2 ]
机构
[1] Calvary Mater Newcastle Hosp, Dept Radiat Oncol, Newcastle, NSW, Australia
[2] Univ Newcastle, Sch Math & Phys Sci, Fac Sci & IT, Newcastle, NSW, Australia
[3] Gosford Hosp, Cent Coast Canc Ctr, Gosford, NSW, Australia
[4] Univ Newcastle, Sch Med Radiat Sci, Newcastle, NSW, Australia
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2017年 / 18卷 / 05期
关键词
gantry angle; quality assurance; VMAT; VOLUMETRIC MODULATED ARC; PROSTATE-CANCER; CINE-MODE; IMRT; THERAPY; VERIFICATION; SYSTEM; QA;
D O I
10.1002/acm2.12129
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Volumetric-modulated arc therapy (VMAT) treatment delivery requires three key dynamic components; gantry rotation, dose rate modulation, and multi-leaf collimator motion, which are all simultaneously varied during the delivery. Misalignment of the gantry angle can potentially affect clinical outcome due to the steep dose gradients and complex MLC shapes involved. It is essential to develop independent gantry angle quality assurance (QA) appropriate to VMAT that can be performed simultaneously with other key VMAT QA testing. In this work, a simple and inexpensive fully independent gantry angle measurement methodology was developed that allows quantitation of the gantry angle accuracy as a function of time. This method is based on the analysis of video footage of a Double dot pattern attached to the front cover of the linear accelerator that consists of red and green circles printed on A4 paper sheet. A standard mobile phone is placed on the couch to record the video footage during gantry rotation. The video file is subsequently analyzed and used to determine the gantry angle from each video frame using the relative position of the two dots. There were two types of validation tests performed including the static mode with manual gantry angle rotation and dynamic mode with three complex test plans. The accuracy was 0.26 degrees +/- 0.04 degrees and 0.46 degrees +/- 0.31 degrees (mean +/- 1 SD) for the static and dynamic modes, respectively. This method is user friendly, cost effective, easy to setup, has high temporal resolution, and can be combined with existing time-resolved method for QA of MLC and dose rate to form a comprehensive set of procedures for time-resolved QA of VMAT delivery system.
引用
收藏
页码:134 / 142
页数:9
相关论文
共 40 条
  • [31] Phase discrimination method for simultaneous two-phase separation in time-resolved stereo PIV measurements
    Cheng, Y.
    Pothos, S.
    Diez, F. J.
    EXPERIMENTS IN FLUIDS, 2010, 49 (06) : 1375 - 1391
  • [32] A novel dynamic robotic moving phantom system for patient-specific quality assurance in real-time tumor-tracking radiotherapy
    Shiinoki, Takehiro
    Fujii, Fumitake
    Fujimoto, Koya
    Yuasa, Yuki
    Sera, Tatsuhiro
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (07): : 16 - 28
  • [33] An error detection method for real-time EPID-based treatment delivery quality assurance
    Alves, Victor Gabriel Leandro
    Ahmed, Mahmoud
    Aliotta, Eric
    Choi, Wookjin
    Siebers, Jeffrey Vincent
    MEDICAL PHYSICS, 2021, 48 (02) : 569 - 578
  • [34] Time-resolved measurements of low concentration aromatic hydrocarbons in diesel exhaust using a resonance enhanced multi-photon ionization method
    Misawa, K.
    Tanaka, K.
    Yamada, H.
    Goto, Y.
    Matsumoto, J.
    Yamato, Y.
    Ishiuchi, S.
    Fujii, M.
    Tanaka, K.
    Endo, K.
    Hayashi, S.
    INTERNATIONAL JOURNAL OF ENGINE RESEARCH, 2009, 10 (06) : 409 - 417
  • [35] Developing a novel method to analyse Gafchromic EBT2 films in intensity modulated radiation therapy quality assurance
    Yunfei Hu
    Yang Wang
    Gerald Fogarty
    Guilin Liu
    Australasian Physical & Engineering Sciences in Medicine, 2013, 36 : 487 - 494
  • [36] Developing a novel method to analyse Gafchromic EBT2 films in intensity modulated radiation therapy quality assurance
    Hu, Yunfei
    Wang, Yang
    Fogarty, Gerald
    Liu, Guilin
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2013, 36 (04) : 487 - 494
  • [37] Quantitative Perfusion Analysis of the Rectum Using Golden-Angle Radial Sparse Parallel Magnetic Resonance Imaging Initial Experience and Comparison to Time-Resolved Angiography With Interleaved Stochastic Trajectories
    Attenberger, Ulrike I.
    Liu, Jing
    Riffel, Philipp
    Budjan, Johannes
    Grimm, Robert
    Block, Kai T.
    Schoenberg, Stefan O.
    Wang, Xiaoying
    Hausmann, Daniel
    INVESTIGATIVE RADIOLOGY, 2017, 52 (12) : 715 - 724
  • [38] A novel quality assurance procedure for trajectory log validation using phantom-less real-time latency corrected EPID images
    Lim, Seng Boh
    Zwan, Benjamin J.
    Lee, Danny
    Greer, Peter B.
    Lovelock, Dale Michael
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (03): : 176 - 185
  • [39] A novel approach to SBRT patient quality assurance using EPID-based real-time transit dosimetryA step to QA with in vivo EPID dosimetry
    Christos Moustakis
    Fatemeh Ebrahimi Tazehmahalleh
    Khaled Elsayad
    Francis Fezeu
    Sergiu Scobioala
    Strahlentherapie und Onkologie, 2020, 196 : 182 - 192
  • [40] A novel turn-off Tb3+/ssDNA complex-based time-resolved fluorescent aptasensor for oxytetracycline detection using the powerful sensitizing property of the modified complementary strand on Tb3+ emission
    Esmaelpourfarkhani, Masoomeh
    Hazeri, Yeganeh
    Ramezani, Mohammad
    Alibolandi, Mona
    Abnous, Khalil
    Taghdisi, Seyed Mohammad
    MICROCHEMICAL JOURNAL, 2024, 199