A novel and independent method for time-resolved gantry angle quality assurance for VMAT

被引:3
作者
Fuangrod, Todsaporn [1 ]
Greer, Peter B. [1 ,2 ]
Zwan, Benjamin J. [2 ,3 ]
Barnes, Michael P. [1 ,2 ,4 ]
Lehmann, Joerg [1 ,2 ]
机构
[1] Calvary Mater Newcastle Hosp, Dept Radiat Oncol, Newcastle, NSW, Australia
[2] Univ Newcastle, Sch Math & Phys Sci, Fac Sci & IT, Newcastle, NSW, Australia
[3] Gosford Hosp, Cent Coast Canc Ctr, Gosford, NSW, Australia
[4] Univ Newcastle, Sch Med Radiat Sci, Newcastle, NSW, Australia
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2017年 / 18卷 / 05期
关键词
gantry angle; quality assurance; VMAT; VOLUMETRIC MODULATED ARC; PROSTATE-CANCER; CINE-MODE; IMRT; THERAPY; VERIFICATION; SYSTEM; QA;
D O I
10.1002/acm2.12129
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Volumetric-modulated arc therapy (VMAT) treatment delivery requires three key dynamic components; gantry rotation, dose rate modulation, and multi-leaf collimator motion, which are all simultaneously varied during the delivery. Misalignment of the gantry angle can potentially affect clinical outcome due to the steep dose gradients and complex MLC shapes involved. It is essential to develop independent gantry angle quality assurance (QA) appropriate to VMAT that can be performed simultaneously with other key VMAT QA testing. In this work, a simple and inexpensive fully independent gantry angle measurement methodology was developed that allows quantitation of the gantry angle accuracy as a function of time. This method is based on the analysis of video footage of a Double dot pattern attached to the front cover of the linear accelerator that consists of red and green circles printed on A4 paper sheet. A standard mobile phone is placed on the couch to record the video footage during gantry rotation. The video file is subsequently analyzed and used to determine the gantry angle from each video frame using the relative position of the two dots. There were two types of validation tests performed including the static mode with manual gantry angle rotation and dynamic mode with three complex test plans. The accuracy was 0.26 degrees +/- 0.04 degrees and 0.46 degrees +/- 0.31 degrees (mean +/- 1 SD) for the static and dynamic modes, respectively. This method is user friendly, cost effective, easy to setup, has high temporal resolution, and can be combined with existing time-resolved method for QA of MLC and dose rate to form a comprehensive set of procedures for time-resolved QA of VMAT delivery system.
引用
收藏
页码:134 / 142
页数:9
相关论文
共 40 条
  • [21] The Temporal Resolution of In Vivo Electroporation in Zebrafish: A Method for Time-Resolved Loss of Function
    Kera, Scott A.
    Agerwala, Suneel M.
    Horne, John H.
    ZEBRAFISH, 2010, 7 (01) : 97 - 108
  • [22] Deconvolution method for recovering the photon time-of-flight distribution from time-resolved measurements
    Diop, Mamadou
    St Lawrence, Keith
    OPTICS LETTERS, 2012, 37 (12) : 2358 - 2360
  • [23] Variation in Elekta iView electronic portal imager pixel scale factor with gantry angle, and impact on multi-leaf collimator quality assurance
    Goodall, Simon K.
    Norvill, Craig
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (07):
  • [24] A Novel Method for Quality Assurance of the Cyberknife Iris Variable Aperture Collimator
    Heidorn, Sarah-Charlotta
    Kremer, Nikolaus
    Furweger, Christoph
    CUREUS, 2016, 8 (05):
  • [25] A novel method for routine quality assurance of volumetric-modulated arc therapy
    Wang, Qingxin
    Dai, Jianrong
    Zhang, Ke
    MEDICAL PHYSICS, 2013, 40 (10)
  • [26] Time-resolved identification of mechanical loadings on plates using the virtual fields method and deflectometry measurements
    O'Donoughue, P.
    Robin, O.
    Berry, A.
    STRAIN, 2018, 54 (03):
  • [27] A novel approach to SBRT patient quality assurance using EPID-based real-time transit dosimetry A step to QA with in vivo EPID dosimetry
    Moustakis, Christos
    Ebrahimi Tazehmahalleh, Fatemeh
    Elsayad, Khaled
    Fezeu, Francis
    Scobioala, Sergiu
    STRAHLENTHERAPIE UND ONKOLOGIE, 2020, 196 (02) : 182 - 192
  • [28] Cloud-Based Monte Carlo Patient-Specific Quality Assurance (QA) Method for Volumetric Modulated Arc Therapy (VMAT)
    Chen, X.
    Xing, L.
    Azcona, J.
    Luxton, G.
    Bush, K.
    MEDICAL PHYSICS, 2014, 41 (06) : 237 - 238
  • [29] Time-Resolved Profiling Reveals ATF3 as a Novel Mediator of Endocrine Resistance in Breast Cancer
    Borgoni, Simone
    Sofyali, Emre
    Soleimani, Maryam
    Wilhelm, Heike
    Mueller-Decker, Karin
    Will, Rainer
    Noronha, Ashish
    Beumers, Lukas
    Verschure, Pernette J.
    Yarden, Yosef
    Magnani, Luca
    van Kampen, Antoine H. C.
    Moerland, Perry D.
    Wiemann, Stefan
    CANCERS, 2020, 12 (10) : 1 - 19
  • [30] A novel method for dose distribution registration using fiducial marks made by a megavoltage beam in film dosimetry for intensity-modulated radiation therapy quality assurance
    Nakayama, Shinichi
    Monzen, Hajime
    Oonishi, Yuuichi
    Mizote, Rika
    Iramina, Hiraku
    Kaneshige, Souichirou
    Mizowaki, Takashi
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (04): : 414 - 419