Effect of bone diameter and eccentric loading on fatigue life of cortical screws used with interlocking nails

被引:26
作者
Aper, RL
Litsky, AS
Roe, SC
Johnson, KA [1 ]
机构
[1] Ohio State Univ, Coll Vet Med, Dept Vet Clin Sci, Columbus, OH 43210 USA
[2] Ohio State Univ, Coll Engn, Ctr Biomed Engn, Columbus, OH 43210 USA
[3] Ohio State Univ, Coll Med & Publ Hlth, Dept Orthopaed, Orthopaed Biomat Lab, Columbus, OH 43210 USA
[4] N Carolina State Univ, Coll Vet Med, Dept Clin Sci, Raleigh, NC 27695 USA
关键词
D O I
10.2460/ajvr.2003.64.569
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective-To test the effects of bone diameter and eccentric loading on fatigue life of 2.7-mm-diameter cortical bone screws used for locking a 6-mm-diameter interlocking nail. Sample Population-Eighteen 2.7-mm-diameter cortical bone screws. Procedure-A simulated bone model with aluminum tubing and a 6-mm-diameter interlocking nail was used to load screws in cyclic 3-point bending. Group I included 6 screws that were centrally loaded within 19-mm-diameter aluminum tubing. Group 2 included 6 screws that were centrally loaded within 31.8-mm-diameter aluminum tubing. Group 3 included 6 screws that were eccentrically loaded (5.5 mm from center) within 31.8-mm-diameter aluminum tubing. The number of cycles until screw failure and the mode of failure were recorded. Results-An increase in the diameter of the aluminum tubing from 19 to 31.8 mm resulted in a significant decrease in the number of cycles to failure (mean +/- SD, 761,215 239,853 to 16,941 2,829 cycles, respectively). Within 31.8-mm tubing, the number of cycles of failure of eccentrically loaded screws (43,068 14,073 cycles) was significantly greater than that of centrally loaded screws (16,941 2,829 cycles). Conclusions and Clinical Relevance-Within a bone, locking screws are subjected to different loading conditions depending on location (diaphyseal vs metaphyseal). The fatigue life of a locking screw centrally loaded in the metaphyseal region of bone may be shorter than in the diaphysis. Eccentric loading of the locking screw in the metaphysis may help to improve its fatigue life.
引用
收藏
页码:569 / 573
页数:5
相关论文
共 21 条
[1]  
*AM I STEEL CONSTR, 1986, MAN STEEL CONSTR LOA, P3
[2]  
BUDSBERG SC, 1987, AM J VET RES, V48, P915
[3]  
Dueland RT, 1999, J AM VET MED ASSOC, V214, P59
[4]  
Dueland RT, 1997, VET COMP ORTHOPAED, V10, P194
[5]  
DUHAUTOIS B, 1995, PRAT MED CHIR ANIM, V30, P614
[6]  
DURALL I, 1994, VET COMP ORTHOPAED, V7, P3
[7]   Early experience with the use of an interlocking nail for the repair of canine femoral shaft fractures [J].
Durall, I ;
Diaz, MC .
VETERINARY SURGERY, 1996, 25 (05) :397-406
[8]   Interlocking intramedullary nail method for the treatment of femoral and tibial fractures in cats and small dogs [J].
Endo, K ;
Nakamura, K ;
Maeda, H ;
Matsushita, T .
JOURNAL OF VETERINARY MEDICAL SCIENCE, 1998, 60 (01) :119-122
[9]   STABILITY OF REAMED AND UNREAMED INTRAMEDULLARY TIBIAL NAILS - A BIOMECHANICAL STUDY [J].
FAIRBANK, AC ;
THOMAS, D ;
CUNNINGHAM, B ;
CURTIS, M ;
JINNAH, RH .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1995, 26 (07) :483-485
[10]  
HIGDON A, 1985, MECH MATER, P565