Seismic design and performance of a steel frame-shear plate shear wall with self-centering energy dissipation braces structure

被引:11
作者
Liu, Jialin [1 ]
Xu, Longhe [1 ]
Xie, Xingsi [1 ]
机构
[1] Beijing Jiaotong Univ, Sch Civil Engn, Beijing 100044, Peoples R China
来源
JOURNAL OF BUILDING ENGINEERING | 2022年 / 51卷
基金
中国国家自然科学基金;
关键词
Steel plate shear wall structure; Self-centering brace; Combined strip model; Seismic design; Nonlinear dynamic analysis; DISPLACEMENT-BASED DESIGN;
D O I
10.1016/j.jobe.2022.104336
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The steel plate shear wall with self-centering energy dissipation braces (SPSW-SCEDB) is a new seismic lateral resistant component. This paper outlines the performance requirements of the steel frame-shear plate shear wall with self-centering energy dissipation braces (SF-SCSPSW) structure and presents a direct displacement-based seismic design method for the structure. A combined strip model of the SPSW-SCEDB that considers the effect of the bolted connection on the wall plate is established. The comparison of the simulated and experimental results shows that the model can accurately predict the strength and hysteretic behavior under cyclic loading. The 8 and 15-story prototype buildings were designed using the presented method. The results of nonlinear dynamic analysis showed that larger inter-story deformations occurred on the lower floors, and the inter-story ratios gradually decreased with an increase in the number of floors. The maximum inter-story drift ratio (1.73%) of the 8-story structure under mega earthquakes and the maximum residual drift ratio (0.018%) of the 15-story structure under large earthquakes were less than the limit values (2% and 0.5%). Local yielding occurred between the brace connection and the column under mega earthquakes, but the columns remained in an elastic state. The seismic responses of the SPSW-SCEDBs in the two structures met the performance requirements of being elastic and suffering light and moderate and serious damage under frequent, medium, large, and mega earthquakes, respectively. The effectiveness of the proposed design method was verified.
引用
收藏
页数:18
相关论文
共 24 条
[1]  
[Anonymous], 2000, 3562000 FEMA
[2]  
[Anonymous], 2016, Code for Seismic Design of Buildings S
[3]  
[Anonymous], 2017, 4117 ASCE
[4]   Seismic damage evaluation in urban areas using the capacity spectrum method: Application to Barcelona [J].
Barbat, Alex H. ;
Pujades, Luis G. ;
Lantada, Nieves .
SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2008, 28 (10-11) :851-865
[5]   Back-of-the-Envelope analysis of plan-asymmetric confined masonry buildings for force-based seismic design [J].
Basu, Dhiman .
JOURNAL OF BUILDING ENGINEERING, 2019, 21 :455-467
[6]   Plastic analysis and design of steel plate shear walls [J].
Berman, J ;
Bruneau, M .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2003, 129 (11) :1448-1456
[7]  
Chopra A.K., 1999, 199902
[8]   The development of a novel analytical model to design composite steel plate shear walls under eccentric shear [J].
Hayatdavoodi, Aliakbar ;
Dehghani, Ayoub ;
Aslani, Farhad ;
Nateghi-Alahi, Fariborz .
JOURNAL OF BUILDING ENGINEERING, 2021, 44
[9]   Experimental study on component performance in steel plate shear wall with self-centering braces [J].
Liu, Jia-Lin ;
Xu, Long-He ;
Li, Zhong-Xian .
STEEL AND COMPOSITE STRUCTURES, 2020, 37 (03) :341-351
[10]   Strip model for steel plate shear walls with beam-connected web plates [J].
Ozcelik, Yigit ;
Clayton, Patricia M. .
ENGINEERING STRUCTURES, 2017, 136 :369-379