Quality evaluation of LC-MS/MS-based E. coli H antigen typing (MS-H) through label-free quantitative data analysis in a clinical sample setup

被引:6
作者
Cheng, Keding [1 ,2 ]
Sloan, Angela [1 ]
McCorrister, Stuart [1 ]
Peterson, Lorea [1 ]
Chui, Huixia [1 ,3 ]
Drebot, Mike [1 ,4 ]
Nadon, Celine [1 ,4 ]
Knox, J. David [1 ,4 ]
Wang, Gehua [1 ]
机构
[1] Publ Hlth Agcy Canada, Natl Microbiol Lab, Winnipeg, MB R3E 3R2, Canada
[2] Univ Manitoba, Fac Med, Dept Human Anat & Cell Sci, Winnipeg, MB, Canada
[3] Henan Ctr Dis Prevent & Control, Hubei, Henan Province, Peoples R China
[4] Univ Manitoba, Fac Med, Dept Med Microbiol, Winnipeg, MB, Canada
关键词
E; coli; Flagella typing; LC-MS; MS; Mass spectrometry; Quality control; ESCHERICHIA-COLI; MASS-SPECTROMETRY; BIOANALYTICAL LC/MS/MS; CARRYOVER; IDENTIFICATION; RESTRICTION; PEPTIDES; PROTEIN; GENE;
D O I
10.1002/prca.201400019
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
PurposeThe need for rapid and accurate H typing is evident during Escherichia coli outbreak situations. This study explores the transition of MS-H, a method originally developed for rapid H antigen typing of E. coli using LC-MS/MS of flagella digest of reference strains and some clinical strains, to E. coli isolates in clinical scenario through quantitative analysis and method validation. Experimental designMotile and nonmotile strains were examined in batches to simulate clinical sample scenario. Various LC-MS/MS batch run procedures and MS-H typing rules were compared and summarized through quantitative analysis of MS-H data output for a standard method development. ResultsLabel-free quantitative data analysis of MS-H typing was proven very useful for examining the quality of MS-H result and the effects of some sample carryovers from motile E. coli isolates. Based on this, a refined procedure and protein identification rule specific for clinical MS-H typing was established and validated. Conclusions and clinical relevanceWith LC-MS/MS batch run procedure and database search parameter unique for E. coli MS-H typing, the standard procedure maintained high accuracy and specificity in clinical situations, and its potential to be used in a clinical setting was clearly established.
引用
收藏
页码:963 / 970
页数:8
相关论文
共 19 条
[1]  
[Anonymous], 2005, VALIDATION ANAL PROC, V4, P1
[2]   System suitability in bioanalytical LC/MS/MS [J].
Briscoe, Chad J. ;
Stiles, Mark R. ;
Hage, David S. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (02) :484-491
[3]   Comparative Study of Traditional Flagellum Serotyping and Liquid Chromatography-Tandem Mass Spectrometry-Based Flagellum Typing with Clinical Escherichia coli Isolates [J].
Cheng, Keding ;
Sloan, Angela ;
Peterson, Lorea ;
McCorrister, Stuart ;
Robinson, Alyssia ;
Walker, Matthew ;
Drew, Tracy ;
McCrea, Joanne ;
Chui, Linda ;
Wylie, John ;
Bekal, Sadjia ;
Reimer, Aleisha ;
Westmacott, Garrett ;
Drebot, Mike ;
Nadon, Celine ;
Knox, J. David ;
Wang, Gehua .
JOURNAL OF CLINICAL MICROBIOLOGY, 2014, 52 (06) :2275-2278
[4]   MS-H: A Novel Proteomic Approach to Isolate and Type the E. coli H Antigen Using Membrane Filtration and Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) [J].
Cheng, Keding ;
Drebot, Mike ;
McCrea, Joanne ;
Peterson, Lorea ;
Lee, David ;
McCorrister, Stuart ;
Nickel, Richard ;
Gerbasi, Alyssia ;
Sloan, Angela ;
Janella, Debra ;
Van Domselaar, Gary ;
Beniac, Daniel ;
Booth, Tim ;
Chui, Linda ;
Tabor, Helen ;
Westmacott, Garrett ;
Gilmour, Matthew ;
Wang, Gehua .
PLOS ONE, 2013, 8 (02)
[5]   Beyond pass/fail: A procedure for evaluating the effect of carryover in bioanalytical LC/MS/MS methods [J].
Clouser-Roche, Andrea ;
Johnson, Kjell ;
Fast, Douglas ;
Tang, Daniel .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 47 (01) :146-155
[6]   Investigation of carryover of peptides in nano-liquid chromatography/mass spectrometry using packed and monolithic capillary columns [J].
Dolman, Sebastiaan ;
Eeltink, Sebastiaan ;
Vaast, Axel ;
Pelzing, Matthias .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 912 :56-63
[7]   Shiga toxin-producing Escherichia coli:: An overview [J].
Gyles, C. L. .
JOURNAL OF ANIMAL SCIENCE, 2007, 85 :E45-E62
[8]   Determination of carryover and contamination for mass spectrometry-based chromatographic assays [J].
Hughes, Nicola C. ;
Wong, Ernest Y. K. ;
Fan, Juan ;
Bajaj, Navgeet .
AAPS JOURNAL, 2007, 9 (03) :E353-E360
[9]   Exponentially modified protein abundance index (emPAI) for estimation of absolute protein amount in proteomics by the number of sequenced peptides per protein [J].
Ishihama, Y ;
Oda, Y ;
Tabata, T ;
Sato, T ;
Nagasu, T ;
Rappsilber, J ;
Mann, M .
MOLECULAR & CELLULAR PROTEOMICS, 2005, 4 (09) :1265-1272
[10]   Determination of Serotypes of Shiga Toxin-Producing Escherichia coli Isolates by Intact Cell Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry [J].
Karger, Axel ;
Ziller, Mario ;
Bettin, Barbara ;
Mintel, Birgit ;
Schares, Susann ;
Geue, Lutz .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2011, 77 (03) :896-905