Osmotic swelling pressure response of smart hydrogels suitable for chronically implantable glucose sensors

被引:76
作者
Lin, G. [1 ]
Chang, S. [2 ]
Hao, H. [3 ]
Tathireddy, P. [4 ]
Orthner, M. [4 ]
Magda, J. [1 ,2 ]
Solzbacher, F. [1 ,4 ,5 ]
机构
[1] Univ Utah, Dept Mat Sci & Engn, Salt Lake City, UT 84112 USA
[2] Univ Utah, Dept Chem Engn, Salt Lake City, UT 84112 USA
[3] NW Univ Xian, Dept Chem Engn, Xian 710069, Peoples R China
[4] Univ Utah, Dept Elect & Comp Engn, Salt Lake City, UT 84112 USA
[5] Univ Utah, Dept Bioengn, Salt Lake City, UT 84112 USA
基金
美国国家卫生研究院;
关键词
Glucose sensor; Hydrogel; Piezoresistive sensor; Smart material; PHENYLBORONIC ACID; IN-VIVO; POLYMER; BLOOD; BIOSENSORS; RECEPTORS; GELS;
D O I
10.1016/j.snb.2009.07.054
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the last few years, anew type of glucose-sensitive hydrogel (GSH) has been developed that shrinks with increasing glucose concentration due to the formation of reversible crosslinks. The first osmotic swelling pressure results measured for any member of this new class of GSH are reported, so that their suitability for use in sensors combining pressure transducers and smart gels can be evaluated. Comparison is also made with results obtained for an older type of GSH that expands with increasing glucose concentration due to an increase in the concentration of counterions within the gel. The newer type of GSH exhibits both faster kinetics and weaker fructose interference, and therefore is more suitable for in vivo glucose sensing. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:332 / 336
页数:5
相关论文
共 31 条
[1]   High ionic strength glucose-sensing photonic crystal [J].
Alexeev, VL ;
Sharma, AC ;
Goponenko, AV ;
Das, S ;
Lednev, IK ;
Wilcox, CS ;
Finegold, DN ;
Asher, SA .
ANALYTICAL CHEMISTRY, 2003, 75 (10) :2316-2323
[2]   A membrane-moderated, conductimetric sensor for the detection and measurement of specific organic solutes in aqueous solutions [J].
Arnold, FH ;
Zheng, WG ;
Michaels, AS .
JOURNAL OF MEMBRANE SCIENCE, 2000, 167 (02) :227-239
[3]   Ophthalmic glucose sensing: a novel monosaccharide sensing disposable and colorless contact lens [J].
Badugu, R ;
Lakowicz, JR ;
Geddes, CD .
ANALYST, 2004, 129 (06) :516-521
[4]   A hydrogel-actuated smart microvalve with a porous diffusion barrier back-plate for active flow control [J].
Baldi, A ;
Gu, YD ;
Loftness, PE ;
Siegel, RA ;
Ziaie, B .
FIFTEENTH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2002, :105-108
[5]   Polymerisation resistant synthesis of methacrylamido phenylboronic acids [J].
D'Hooge, Francois ;
Rogalle, Damien ;
Thatcher, Michael J. ;
Perera, Semali P. ;
van den Elsen, Jean M. H. ;
Jenkins, A. Toby A. ;
James, Tony D. ;
Fossey, John S. .
POLYMER, 2008, 49 (16) :3362-3365
[6]  
Dusek K., 1969, FORTSCHR HOCHPOLYMER, V6, P1
[7]  
Flory P J., PRINCIPLES POLYM CHE
[8]   'Smart' polymers and what they could do in biotechnology and medicine [J].
Galaev, IY ;
Mattiasson, B .
TRENDS IN BIOTECHNOLOGY, 1999, 17 (08) :335-340
[9]  
GEHRKE SH, 1993, ADV POLYM SCI, V110, P81
[10]   Protein interactions with subcutaneously implanted biosensors [J].
Gifford, R ;
Kehoe, JJ ;
Barnes, SL ;
Kornilayev, BA ;
Alterman, MA ;
Wilson, GS .
BIOMATERIALS, 2006, 27 (12) :2587-2598