SPRING-RIO TSE: 2D T2-Weighted Turbo Spin-Echo brain imaging using SPiral RINGs with retraced in/out trajectories

被引:7
作者
Wang, Zhixing [1 ]
Allen, Steven P. [1 ,2 ]
Feng, Xue [1 ]
Mugler, John P., III [3 ]
Meyer, Craig H. [1 ,3 ]
机构
[1] Univ Virginia, Dept Biomed Engn, Box 800759, Charlottesville, VA 22908 USA
[2] Brigham Young Univ, Dept Elect & Comp Engn, Provo, UT USA
[3] Univ Virginia, Dept Radiol Med Imaging, Charlottesville, VA USA
关键词
fast imaging; neuroimaging; spiral imaging; T-2-weighted imaging; OFF-RESONANCE CORRECTION; FIELD; RECONSTRUCTION; MRI; INHOMOGENEITY; ARTIFACTS; SEQUENCES;
D O I
10.1002/mrm.29210
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To develop a new approach to 2D turbo spin -echo (TSE) imaging using annular spiral rings with a retraced in/out trajectory, dubbed "SPRING-RIO TSE", for fast T-2-weighted brain imaging at 3T. Methods A long spiral trajectory was split into annular segmentations that were then incorporated into a 2D TSE acquisition module to fully exploit the sampling efficiency of spiral rings. A retraced in/out trajectory strategy coupled with spiral-ring TSE was introduced to increase SNR, mitigate T-2-decay induced artifacts, and self-correct moderate off-resonance while maintaining the target TE and causing no scan time penalty. Model-based k-space estimation and semiautomatic off-resonance correction algorithms were implemented to minimize effects of k-space trajectory infidelity and B-0 inhomogeneity, respectively. The resulting SPRING-RIO TSE method was compared to the original spiral-ring (abbreviated "SPRING") TSE and Cartesian TSE using simulations, and phantom and in vivo acquisitions. Results Simulation and phantom studies demonstrated the performance of the proposed SPRING-RIO TSE pulses sequence, as well as that of trajectory correction and off-resonance correction. Volunteer data showed that the proposed method achieves high-quality 2D T-2-weighted brain imaging with a higher scan efficiency (0:45 min/14 slices versus 1:31 min/14 slices), improved image contrast, and reduced specific absorption rate compared to conventional 2D Cartesian TSE. Conclusion 2D T-2-weighted brain imaging using spiral-ring TSE was implemented and tested, providing several potential advantages over conventional 2D Cartesian TSE imaging.
引用
收藏
页码:601 / 616
页数:16
相关论文
共 50 条
[21]   T2 quantification in brain using 3D fast spin-echo imaging with long echo trains [J].
Snyder, Jeff ;
McPhee, Kelly C. ;
Wilman, Alan H. .
MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (05) :2145-2160
[22]   Accelerating anatomical 2D turbo spin echo imaging of the ankle using compressed sensing [J].
Gersing, Alexandra S. ;
Bodden, Jannis ;
Neumann, Jan ;
Diefenbach, Maximillian N. ;
Kronthaler, Sophia ;
Pfeiffer, Daniela ;
Knebel, Carolin ;
Baum, Thomas ;
Schwaiger, Benedikt J. ;
Hock, Andreas ;
Rummeny, Ernst J. ;
Woertler, Klaus ;
Karampinos, Dimitrios C. .
EUROPEAN JOURNAL OF RADIOLOGY, 2019, 118 :277-284
[23]   Fast-recovery fast spin-echo T2-weighted MR imaging: a free-breathing alternative to fast spin-echo in the pediatric abdomen [J].
I-Hua Huang ;
Kathleen H. Emery ;
Tal Laor ;
Mona Valentine ;
Jan Tiefermann .
Pediatric Radiology, 2008, 38 :675-679
[24]   Fast-recovery fast spin-echo T2-weighted MR imaging: a free-breathing alternative to fast spin-echo in the pediatric abdomen [J].
Huang, I-Hua ;
Emery, Kathleen H. ;
Laor, Tal ;
Valentine, Mona ;
Tiefermann, Jan .
PEDIATRIC RADIOLOGY, 2008, 38 (06) :675-679
[25]   Accuracy of 2D BLADE Turbo Gradient- and Spin-Echo Diffusion Weighted Imaging for the Diagnosis of Primary Middle Ear Cholesteatoma [J].
Lin, Mengyan ;
Sha, Yan ;
Sheng, Yaru ;
Chen, Wei .
OTOLOGY & NEUROTOLOGY, 2022, 43 (06) :E651-E657
[26]   Comparative study of image quality between axial T2-weighted BLADE and turbo spin-echo MRI of the upper abdomen on 3.0 T [J].
Zhang, Lin ;
Tian, ChunMei ;
Wang, PeiYuan ;
Chen, Liang ;
Mao, Xijin ;
Wang, ShanShan ;
Wang, Xu ;
Dong, JingMin ;
Wang, Bin .
JAPANESE JOURNAL OF RADIOLOGY, 2015, 33 (09) :585-590
[27]   Comparative study of image quality between axial T2-weighted BLADE and turbo spin-echo MRI of the upper abdomen on 3.0 T [J].
Lin Zhang ;
ChunMei Tian ;
PeiYuan Wang ;
Liang Chen ;
XiJin Mao ;
ShanShan Wang ;
Xu Wang ;
JingMin Dong ;
Bin Wang .
Japanese Journal of Radiology, 2015, 33 :585-590
[28]   Characterization of carotid atherosclerosis with black-blood carotid plaque imaging using variable flip-angle 3D turbo spin-echo: Comparison with 2D turbo spin-echo sequences [J].
Takano, Koichi ;
Yamashita, Shinnichi ;
Takemoto, Koichiro ;
Inoue, Tooru ;
Sakata, Noriyuki ;
Kuwabara, Yasuo ;
Yoshimitsu, Kengo .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (03) :E304-E309
[29]   Locally advanced rectal cancer: 3D diffusion-prepared stimulated-echo turbo spin-echo versus 2D diffusion-weighted echo-planar imaging [J].
Zhang, Qinwei ;
van Houdt, Petra J. ;
Lambregts, Doenja M. J. ;
van Triest, Baukelien ;
Kop, Marnix P. M. ;
Coolen, Bram F. ;
Strijkers, Gustav J. ;
van der Heide, Uulke A. ;
Nederveen, Aart J. .
EUROPEAN RADIOLOGY EXPERIMENTAL, 2020, 4 (01)
[30]   Evaluation of Selective Bundle Injury to the Anterior Cruciate Ligament: T2-Weighted Fast Spin-Echo 3-T MRI With Reformatted 3D Oblique Isotropic (VISTA) Versus 2D Technique [J].
Lee, Jung Eun ;
Park, Hee Jin ;
Lee, So Yeon ;
Ahn, Jin Hwan ;
Park, Jai Hyung ;
Park, Ji Yeon .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 209 (05) :W308-W316