Estimation of switching surge flashover rate of 1200-kV UHVAC transmission line considering switching overvoltage waveshape

被引:2
|
作者
Annadi, Ramchandra Reddy [1 ]
Patsa, Chandra Sekhar [1 ]
机构
[1] Mahatma Gandhi Inst Technol, Dept EEE, Hyderabad, India
关键词
Switching overvoltage; Switching surge flashover rate; Transmission line; Ultra-high-voltage (UHV) AC system; Wave front time; IMPULSE BREAKDOWN; FAILURE RISK; INSULATION; STRENGTH; FAULTS;
D O I
10.1007/s00202-020-00918-7
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The insulation of the power transmission system experiences stresses due to power-frequency voltage under normal operating conditions, temporary overvoltages at or near power-frequency and transient overvoltages arising either from switching operations and faults or from lightning discharges. However, in the insulation design of extra-high-voltage and ultra-high-voltage systems, transient overvoltages arising from switching operations and faults become the controlling factor. Insulation failure probability under switching overvoltages is the main impressive concern in the estimation of switching surge flashover rate. In this paper, a practical method is used to estimate the switching surge flashover rate of insulation under switching overvoltages generated during energization, re-energization, fault initiation and fault clearing of an unloaded transmission line, which considers the variable characteristics of the insulation strength of the transmission line according to the switching overvoltage waveshape. The results focus on the comparison between traditional and practical methods which considers the effect of the front time on the first 1200-kV UHVAC transmission line in India.
引用
收藏
页码:953 / 966
页数:14
相关论文
共 18 条
  • [1] Estimation of switching surge flashover rate of 1200-kV UHVAC transmission line considering switching overvoltage waveshape
    Ramchandra Reddy Annadi
    Chandra Sekhar Patsa
    Electrical Engineering, 2020, 102 : 953 - 966
  • [2] Estimation of Switching Surge Flashover Rate for a 1200 kV UHVAC Transmission Line
    Reddy, A. Ramchandra
    Sekhar, P. Chandra
    2017 7TH INTERNATIONAL CONFERENCE ON POWER SYSTEMS (ICPS), 2017, : 358 - 363
  • [3] Estimation of Switching Surge Flashover Rate of a 1200 kV UHVAC Transmission Line due to Switching Overvoltages
    Ramchandra Reddy Annadi
    Chandra Sekhar Patsa
    INAE Letters, 2018, 3 (3): : 167 - 174
  • [4] Failure Risk of UHV AC Transmission Line Considering the Statistical Characteristics of Switching Overvoltage Waveshape
    Li, Yang
    He, Jinliang
    Yuan, Jun
    Li, Chen
    Hu, Jun
    Zeng, Rong
    IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (03) : 1731 - 1739
  • [5] SWITCHING SURGE FLASHOVER OF UHV TRANSMISSION LINE INSULATION
    KACHLER, AJ
    LAFOREST, JJ
    ZAFFANEL.LE
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1971, PA90 (04): : 1604 - &
  • [6] Studies of line switching overvoltage on the 150 kV and 500 kV transmission network of UTE
    Aparicio, Sofia
    Pizzini, Andrea
    Martinez, Roberto
    Curbelo, Carlos
    2018 IEEE 9TH POWER, INSTRUMENTATION AND MEASUREMENT MEETING (EPIM), 2018,
  • [7] Statistical Switching Overvoltages of 1200 kV UHV AC Transmission Line
    Annadi R.R.
    Patsa C.S.
    Journal of The Institution of Engineers (India): Series B, 2022, 103 (01) : 189 - 195
  • [8] Research on switching overvoltage in 1000 kV ultra-HVAC transmission line
    Xu, W., 2005, Chinese Society for Electrical Engineering (25):
  • [9] APPLE GROVE 750-KV PROJECT - 500-KV SWITCHING SURGE AND LINE FLASHOVER TESTS
    BARNES, HC
    MCELROY, AJ
    SHANKLE, DF
    SMITH, HM
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1965, PA84 (07): : 550 - &
  • [10] Estimation of switching surge flashover rate of point on wave switching over-voltages along transmission line by adaptive neuro-fuzzy inference system meta-model
    Hasanpour, Mojtaba
    Ghanbari, Mahmood
    Parvin-Darabad, Vahid
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2019, 13 (09) : 1326 - 1335