Valsalva maneuver procedures in the diagnosis of right-to-left shunt by contrast-enhanced transcranial doppler using agitated saline solution with blood as a contrast agent

被引:6
作者
Lange, Marcos Christiano [1 ]
Zetola, Viviane Flumignan [1 ]
Piovesan, Elcio Juliato [1 ]
Werneck, Lineu Cesar [1 ]
机构
[1] Univ Fed Parana, Serv Neurol, Hosp Clin, Cerebrovasc Dis Unit,Neurol Div,Internal Med Dept, BR-80060900 Curitiba, Parana, Brazil
关键词
contrast media; paradoxical embolism; microbubbles; transcranial doppler; ultrasonography; Valsalva maneuver; PATENT FORAMEN OVALE; ULTRASOUND;
D O I
10.1590/S0004-282X2010000300016
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Objective: To compare two different timings for the performance of the Valsalva maneuver (VM) using an infusion of agitated saline solution with blood as contrast agent (CA) to right-to-left shunt (RLS) screening. Method: 42 patients were submitted to a standardized contrast-enhanced transcranial doppler (cTCD) to screen for right-to-left shunt (RLS). cTCD technique was done with two different moments of the VM: [1] the CA injection during the VM (CAduringVM test); [2] the CA injection before the VM (CApreVM test). Results: Positive MCA tests were observed in 47 (56%) CAduringVM tests and in 50 (59.5%) CApreVM tests, p=0.64. There was an almost perfect agreement for the positive tests between the CAduringVM and CApreVM test, r(s)=0.829 (95% Cl 0.61-1.00, p<0.001). Conclusion: The present study demonstrates that there is no significant difference in the results of RLS screening by cTCD when two different moments of VM were done.
引用
收藏
页码:410 / 413
页数:4
相关论文
共 11 条
  • [1] BICKEL A, 2007, CLIN NEUROPHYSIOL, V118, P16
  • [2] Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts -: Time window and threshold in microbubble numbers
    Droste, DW
    Silling, K
    Stypmann, J
    Grude, M
    Kemény, V
    Wichter, T
    Kühne, K
    Ringelstein, EB
    [J]. STROKE, 2000, 31 (07) : 1640 - 1645
  • [3] Detection of right-to-left shunt with ultrasound contrast agent and transcranial Doppler sonography
    Jauss, M
    Zanette, E
    [J]. CEREBROVASCULAR DISEASES, 2000, 10 (06) : 490 - 496
  • [4] TRANSCRANIAL DOPPLER FOR PATENT FORAMEN OVALE SCREENING Is there a good correlation with transesophageal echocardiography?
    Lange, Marcos Christiano
    Zetola, Viviane Flumignan
    de Souza, Admar Moraes
    Piovesan, Elcio Juliato
    Muzzio, Juliano Andre
    Branco Germiniani, Francisco Manoel
    Werneck, Lineu Cesar
    [J]. ARQUIVOS DE NEURO-PSIQUIATRIA, 2008, 66 (04) : 785 - 789
  • [5] Power M-mode Doppler (PMD) for observing cerebral blood flow and tracking emboli
    Moehring, MA
    Spencer, MP
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (01) : 49 - 57
  • [6] Middle cerebral artery blood velocity during a Valsalva maneuver in the standing position
    Pott, F
    Van Lieshout, JJ
    Ide, K
    Madsen, P
    Secher, NH
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2000, 88 (05) : 1545 - 1550
  • [7] Ringelstein EB, 1998, STROKE, V29, P725
  • [8] Saqqur M, 2004, STROKE, V35, P14
  • [9] Is transcranial Doppler for the detection of venous-to-arterial circulation shunts reproducible?
    Sastry, S.
    Daly, K.
    Chengodu, T.
    McCollum, C.
    [J]. CEREBROVASCULAR DISEASES, 2007, 23 (5-6) : 424 - 429
  • [10] Methodological parameters influence the detection of right-to-left shunts by contrast transcranial Doppler ultrasonography
    Schwarze, JJ
    Sander, D
    Kukla, C
    Wittich, I
    Babikian, VL
    Klingelhöfer, J
    [J]. STROKE, 1999, 30 (06) : 1234 - 1239