Potential application of novel technology developed for instant decontamination of personal protective equipment before the doffing step

被引:6
作者
Breda Mascarenhas, Luis Alberto [1 ]
Machado, Bruna Aparecida Souza [1 ,2 ]
Rodrigues, Leticia de Alencar Pereira [1 ]
Saraiva Hodel, Katharine Valeria [1 ]
Bandeira Santos, Alex Alisson [2 ]
Freitas Neves, Paulo Roberto [2 ]
da Silva Andrade, Leone Peter Correia [1 ]
Soares, Milena Botelho [1 ,3 ]
de Andrade, Jailson Bittencourt [1 ]
Badaro, Roberto [1 ]
机构
[1] Univ Ctr SENAI CIMATEC, SENAI CIMATEC, SENAI Inst Innovat ISI Hlth Adv Syst, CIMATEC ISI SAS, Salvador, BA, Brazil
[2] Univ Ctr SENAI CIMATEC, Computat Modeling & Ind Technol, Natl Serv Ind Learning SENAI, SENAI CIMATEC, Bahia Blanca, Buenos Aires, Argentina
[3] Oswaldo Cruz Fdn IGM FIOCRUZ, Goncalo Moniz Inst, Salvador, BA, Brazil
来源
PLOS ONE | 2021年 / 16卷 / 06期
关键词
SODIUM-HYPOCHLORITE; HEALTH-CARE; INANIMATE SURFACES; BIOFILM FORMATION; CANDIDA-AURIS; DISINFECTION; CONTAMINATION; COVID-19; SYSTEM; INACTIVATION;
D O I
10.1371/journal.pone.0250854
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The use of personal protective equipment (PPE) has been considered the most effective way to avoid the contamination of healthcare workers by different microorganisms, including SARS-CoV-2. A spray disinfection technology (chamber) was developed, and its efficacy in instant decontamination of previously contaminated surfaces was evaluated in two exposure times. Seven test microorganisms were prepared and inoculated on the surface of seven types of PPE (respirator mask, face shield, shoe, glove, cap, safety glasses and lab coat). The tests were performed on previously contaminated PPE using a manikin with a motion device for exposure to the chamber with biocidal agent (sodium hypochlorite) for 10 and 30s. In 96.93% of the experimental conditions analyzed, the percentage reduction was >99% (the number of viable cells found on the surface ranged from 4.3x10(6) to <10 CFU/mL). The samples of E. faecalis collected from the glove showed the lowest percentages reduction, with 86.000 and 86.500% for exposure times of 10 and 30 s, respectively. The log(10) reduction values varied between 0.85 log(10) (E. faecalis at 30 s in glove surface) and 9.69 log(10) (E. coli at 10 and 30 s in lab coat surface). In general, E. coli, S. aureus, C. freundii, P. mirabilis, C. albicans and C. parapsilosis showed susceptibility to the biocidal agent under the tested conditions, with >99% reduction after 10 and 30s, while E. faecalis and P. aeruginosa showed a lower susceptibility. The 30s exposure time was more effective for the inactivation of the tested microorganisms. The results show that the spray disinfection technology has the potential for instant decontamination of PPE, which can contribute to an additional barrier for infection control of healthcare workers in the hospital environment.
引用
收藏
页数:24
相关论文
共 106 条
  • [1] Understanding the antimicrobial activity of selected disinfectants against methicillin-resistant Staphylococcus aureus (MRSA)
    Aboualizadeh, Ebrahim
    Bumah, Violet V.
    Masson-Meyers, Daniela S.
    Eells, Janis T.
    Hirschmugl, Carol J.
    Enwemeka, Chukuka S.
    [J]. PLOS ONE, 2017, 12 (10):
  • [2] Dynamic Transmission of Staphylococcus Aureus in the Intensive Care Unit
    Adams, Claire E.
    Dancer, Stephanie J.
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (06)
  • [3] Supporting the Health Care Workforce During the COVID-19 Global Epidemic
    Adams, James G.
    Walls, Ron M.
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2020, 323 (15): : 1439 - 1440
  • [4] Evaluation of three different decontamination techniques on biofilm formation, and on physical and chemical properties of resin composites
    Andre, Carolina Bosso
    dos Santos, Andressa
    Pfeifer, Carmem Silvia
    Giannini, Marcelo
    Girotto, Emerson Marcelo
    Ferracane, Jack Liborio
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2018, 106 (03) : 945 - 953
  • [5] [Anonymous], 2009, M44A2 CLSI
  • [6] [Anonymous], 2020, EUR HEART J, DOI DOI 10.1093/eurheartj/ehaa283
  • [7] Anvisa, 2020, HUBUNGAN INTERNASION, P1
  • [8] Anvisa, 2019, BRAZ PHARM, P1
  • [9] Effect of treatment with an overheated dry-saturated steam vapour disinfection system on multidrug and extensively drug-resistant nosocomial pathogens and comparison with sodium hypochlorite activity
    Bagattini M.
    Buonocore R.
    Giannouli M.
    Mattiacci D.
    Bellopede R.
    Grimaldi N.
    Nardone A.
    Zarrilli R.
    Triassi M.
    [J]. BMC Research Notes, 8 (1)
  • [10] Virulence plasmid (pYV)-associated susceptibility of Yersinia enterocolitica to chlorine and heavy metals
    Bansal, N
    Sinha, I
    Virdi, JS
    [J]. JOURNAL OF APPLIED MICROBIOLOGY, 2000, 89 (04) : 663 - 667