Thermal and electrical performance analysis of induction heating based-thermochemical reactor for heat storage integration into power systems

被引:6
作者
Bio Gassi, Karim [1 ]
Guene Lougou, Bachirou [2 ]
Baysal, Mustafa [1 ]
Ahouannou, Clement [3 ]
机构
[1] Yildiz Tech Univ, Smart Home Lab, TR-34220 Esenler, Turkey
[2] Harbin Inst Technol, Key Lab Aerosp Thermophys MIIT, Harbin, Peoples R China
[3] Abomey Calavi Univ, Lab Energet & Appl Mech LEMA, Polytechn Coll Abomey Calavi, Cotonou, Benin
关键词
electromagnetic field; induction heating; magneto-motive force; radiation heat transfer; relative permeability; surface emissivity; ENERGY-STORAGE; SUBLIMATION GROWTH; SOLAR RECEIVER; CO2; REDUCTION; TEMPERATURE; DESIGN; OPTIMIZATION; EFFICIENCY; CONVERSION; PYROLYSIS;
D O I
10.1002/er.6947
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this study, the thermal and electrical performance analysis of an induction heating based-thermochemical reactor is investigated for high-temperature heat storage. The induction-heating model is built with Maxwell equations, and the surface-to-surface (S2S) radiation model is used for the induced and diffused thermal energy flow transport in the fluid phase within the reactor inner cavity. The effects of operating and structural parameters in terms of the coil turn number, coil current intensity and frequency, the conductive plate, and the coil's relative permeability, electrical conductivity, and emissivity could affect the heat generation, input power demand, and energy consumption of the proposed reactor performance are sufficiently investigated. It is found that the reactor temperature distribution resulted from the homogenized multi-turn coil magnetomotive force and frequency with the current intensity 48% more effective in reaching the desired temperature at the heat storage medium. However, the conductive plate relative permeability, electrical conductivity, and surface emissivity significantly affect the induction heating system's thermal power, with the relative permeability having the highest impact of 13% in the storage medium's temperature increasing at low current intensity. Moreover, the surface emissivity shows remarkable effects when the inducting heating operates at a high current. Significant energy consumption, more than 159%, is observed when the induction heating generator operates at steady-state mode. The reactor heating region temperature increases when the reactor operating current and frequency get high. It is observed that the more the induced heat was applied to the reactor, the more the reactor is heating up to a steady-state. The instantaneous temperature distribution inside the reactor depicted the rise in the temperature is caused by convection and radiation heat transfer. Higher and more uniform temperature distribution inside the reactor is obtained by optimizing the reactor operating and structural parameters.
引用
收藏
页码:17982 / 18001
页数:20
相关论文
共 50 条
  • [21] Evaluation of localized heat transfer coefficient for induction heating apparatus by thermal fluid analysis based on the HSMAC method
    Namiki, Satoshi
    Iino, Tomoya
    Okamoto, Yoshifumi
    OPEN PHYSICS, 2020, 18 (01): : 504 - 511
  • [22] Performance analysis of a high-temperature magnesium hydride reactor tank with a helical coil heat exchanger for thermal storage
    Mathew, Arun
    Nadim, Nima
    Chandratilleke, Tilak T.
    Humphries, Terry D.
    Paskevicius, Mark
    Buckley, Craig E.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2021, 46 (01) : 1038 - 1055
  • [23] Sensitivity analysis and optimization of geometric and operational parameters in a thermochemical heat storage redox reactor used for concentrated solar power plants
    Mehdi Ebadi
    Mehdi Mehrpooya
    Alireza H. Kani
    Journal of Thermal Analysis and Calorimetry, 2022, 147 : 6415 - 6435
  • [24] Simulation-based performance evaluation of large-scale thermal energy storage coupled with heat pump in district heating systems
    Tosatto, Alice
    Dahash, Abdulrahman
    Ochs, Fabian
    JOURNAL OF ENERGY STORAGE, 2023, 61
  • [25] Performance analysis of an energy system with multiple combined cooling, heating and power systems considering hybrid shared energy storage
    Li, Yaohong
    Wei, Mingshan
    Tian, Ran
    APPLIED THERMAL ENGINEERING, 2023, 233
  • [26] From copper concentrate to Cu-based metal oxides for thermochemical heat storage: Impurity impact analysis and redox performance optimization
    Xiao, Gang
    Zhou, Jiahui
    Deng, Jiali
    Gu, Changdong
    Xu, Haoran
    Zhou, Jinsong
    Zhu, Peiwang
    Shou, Chunhui
    SOLAR ENERGY, 2024, 268
  • [27] Performance analysis of solar thermal storage systems with packed bed utilizing form-stable phase change materials and heat pump integration
    Wang, Changling
    Gao, Yuanzhi
    Yang, Juan
    Liu, Baobin
    Dai, Zhaofeng
    Wu, DongXu
    Xia, Yujiang
    Yu, Jing
    Yan, Weidong
    Zhang, Xiaosong
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2024, 16 (03)
  • [28] Method for evaluating the dynamic thermal performance of heating terminals based on an analysis of heat quantity and grade
    Duan, Mengfan
    Sun, Hongli
    Wu, Yifan
    Lin, Borong
    ENERGY AND BUILDINGS, 2021, 252 (252)
  • [29] Combined cooling, heating, and power generation performance of pumped thermal electricity storage system based on Brayton cycle
    Zhang, Han
    Wang, Liang
    Lin, Xipeng
    Chen, Haisheng
    APPLIED ENERGY, 2020, 278
  • [30] Techno-economic analysis on the design of sensible and latent heat thermal energy storage systems for concentrated solar power plants
    Liu, Ming
    Jacob, Rhys
    Belusko, Martin
    Riahi, Soheila
    Bruno, Frank
    RENEWABLE ENERGY, 2021, 178 : 443 - 455