Compressive properties and analytical modelling for stress-strain curves of polyvinyl alcohol fiber reinforced concrete

被引:48
作者
Sagar, Bhanavath [1 ]
Sivakumar, M. V. N. [1 ]
机构
[1] Natl Inst Technol Warangal, Dept Civil Engn, Hanamkonda, Telangana, India
关键词
PVA fiber reinforced concrete; Analytical stress-strain model; Engineering properties; Load-deflection behaviour; Modified reinforcing index; HIGH-STRENGTH CONCRETE; PVA FIBER; CEMENTITIOUS COMPOSITES; MECHANICAL-PROPERTIES; FRACTURE-BEHAVIOR; GEOPOLYMER; CRACKING;
D O I
10.1016/j.conbuildmat.2021.123192
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The use of polyvinyl alcohol (PVA) fibers in the manufacturing of fiber reinforced concrete is considered a technological revolution in the concrete construction industry due to its advantageous mechanical properties. In this regard, this paper presents the experimental and analytical study of three different grades of PVA fiber reinforced concretes (PVAFRCs) i.e., PVAFRC30, PVAFRC50, and PVAFRC70. A total of eighteen mixes developed for three different grades of PVAFRC with various percentages of PVA fibers (0, 0.1%, 0.2%, 0.3%, 0.4%, 0.5%). Workability, and compressive strength, flexural strength, split tensile strength, load-deflection behaviour, and uniaxial compressive stress-strain behaviour of PVAFRCs have experimentally evaluated. The stress ratio, strain ratio, peak-stress, strain at peak-stress, Young's modulus, compressive toughness index, and energy absorption capacity of PVAFRCs also have been evaluated analytically. The results indicated that the addition of PVA fibers reduced the workability of PVAFRCs mixes and caused significant changes in engineering properties of the concrete. In all three grades of PVAFRC mixes, good mechanical properties exhibited at 0.3% PVA fiber content. The modified analytical model and relationships between material parameter (beta(n)) and modified reinforcing index (MRIV) are proposed to predict the uniaxial compressive stress-strain curves of different grades of PVAFRCs, and a good agreement with experimental results was observed. The existing relationships between material parameter and reinforcing index reported in previous studies for analytical modelling of the experimental compressive stress-strain behaviour of FRC are not able to accurately predict in case of PVAFRCs. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:18
相关论文
共 74 条
[11]  
[Anonymous], 1993, 5443R93 ACI
[12]  
[Anonymous], 1999, IS 9103
[13]  
[Anonymous], 2009, IS 10262
[14]  
[Anonymous], 2014, Standard Test Methods for Determining Average Grain Size, P1, DOI DOI 10.1520/C0469
[15]  
[Anonymous], 2004, Method of Tests for Strength of Concrete -specifications
[16]   Study on PVA fiber surface modification for strain-hardening cementitious composites (PVA-SHCC) [J].
Arain, Muhammad Fahad ;
Wang Mingxue ;
Chen Jianyong ;
Zhang Huapeng .
CONSTRUCTION AND BUILDING MATERIALS, 2019, 197 :107-116
[17]   Behavior of PVA Fiber-Reinforced Cementitious Composites under Static and Impact Flexural Effects [J].
Atahan, Hakan Nuri ;
Pekmezci, Bekir Yilmaz ;
Tuncel, Erman Yigit .
JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2013, 25 (10) :1438-1445
[18]  
Ayub T., 2014, J APPL SCI ENG TECHN, V8, P1174, DOI [10.19026/rjaset.8.1083, DOI 10.19026/RJASET.8.1083]
[19]  
Ayub T., 2014, SCI WORLD J, V567
[20]   Analytical model for the compressive stress-strain behavior of PVA-FRC [J].
Ayub, Tehmina ;
Khan, Sadaqat Ullah ;
Ayub, Ayesha .
CONSTRUCTION AND BUILDING MATERIALS, 2019, 214 :581-593