Implant Platform Switching: Biomechanical Approach Using Two-Dimensional Finite Element Analysis

被引:28
作者
Tabata, Lucas Fernando [1 ]
Assuncao, Wirley Goncalves [1 ]
Ricardo Barao, Valentim Adelino [1 ]
Capello de Sousa, Edson Antonio [2 ]
Gomes, Erica Alves [1 ]
Delben, Juliana Aparecida [1 ]
机构
[1] Univ Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16015050 Sao Paulo, Brazil
[2] Univ Estadual Paulista, Bauru Engn Sch, Dept Mech Engn, BR-16015050 Sao Paulo, Brazil
基金
美国国家卫生研究院; 英国惠康基金;
关键词
Dental implants; platform switching; implant supported prosthesis; finite element analysis; stress distribution; crestal bone loss; TITANIUM IMPLANTS; OSSEOINTEGRATED IMPLANTS; FIXED PROSTHESES; MARGINAL BONE; CRESTAL BONE; STRESS-DISTRIBUTION; BIOLOGIC WIDTH; ORAL IMPLANTS; IN-VIVO; DOG;
D O I
10.1097/SCS.0b013e3181c50eb8
中图分类号
R61 [外科手术学];
学科分类号
摘要
In implant therapy, a peri-implant bone resorption has been noticed mainly in the first year after prosthesis insertion. This bone remodeling can sometimes jeopardize the outcome of the treatment, especially in areas in which short implants are used and also in aesthetic cases. To avoid this occurrence, the use of platform switching (PS) has been used. This study aimed to evaluate the biomechanical concept of PS with relation to stress distribution using two-dimensional finite element analysis. A regular matching diameter connection of abutment-implant (regular platform group [RPG]) and a PS connection (PS group [PSG]) were simulated by 2 two-dimensional finite element models that reproduced a 2-piece implant system with peri-implant bone tissue. A regular implant (prosthetic platform of 4.1 mm) and a wide implant (prosthetic platform of 5.0 mm) were used to represent the RPG and PSG, respectively, in which a regular prosthetic component of 4.1 mm was connected to represent the crown. A load of 100 N was applied on the models using ANSYS software. The RPG spreads the stress over a wider area in the peri-implant bone tissue (159 MPa) and the implant (1610 MPa), whereas the PSG seems to diminish the stress distribution on bone tissue (34 MPa) and implant (649 MPa). Within the limitation of the study, the PS presented better biomechanical behavior in relation to stress distribution on the implant but especially in the bone tissue (80% less). However, in the crown and retention screw, an increase in stress concentration was observed.
引用
收藏
页码:182 / 187
页数:6
相关论文
共 45 条
  • [1] Abrahamsson I, 1998, CLIN ORAL IMPLAN RES, V9, P73
  • [2] CLINICAL-RESULTS OF OSSEOINTEGRATED IMPLANTS SUPPORTING FIXED PROSTHESES IN EDENTULOUS JAWS
    ADELL, R
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1983, 50 (02) : 251 - 254
  • [3] ALBREKTSSON T, 1986, DENT CLIN N AM, V30, P151
  • [4] Assenza Bartolomeo, 2003, Implant Dent, V12, P235
  • [5] Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog
    Barbier, L
    Vander Sloten, J
    Krzesinski, G
    Schepers, E
    Van Der Perre, G
    [J]. JOURNAL OF ORAL REHABILITATION, 1998, 25 (11) : 847 - 858
  • [6] Barbier L, 1997, INT J ORAL MAX IMPL, V12, P215
  • [7] Influence of platform switching on crestal bone changes at non-submerged titanium implants: a histomorphometrical study in dogs
    Becker, Juergen
    Ferrari, Daniel
    Herten, Monika
    Kirsch, Axel
    Schaer, Alex
    Schwarz, Frank
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 2007, 34 (12) : 1089 - 1096
  • [8] Dimension of the periimplant mucosa - Biological width revisited
    Berglundh, T
    Lindhe, J
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1996, 23 (10) : 971 - 973
  • [9] Bidez M W, 1992, Implant Dent, V1, P289, DOI 10.1097/00008505-199200140-00011
  • [10] Binon PP, 1996, INT J PROSTHODONT, V9, P149