Viewing conditions for diagnostic images in three major Dublin hospitals: a comparison with WHO and CEC recommendations

被引:17
作者
McCarthy, E [1 ]
Brennan, PC [1 ]
机构
[1] UCD, Sch Diagnost Imaging, Dublin 4, Ireland
关键词
D O I
10.1259/bjr/92036272
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Accurate interpretation of X-ray images is dependent on image viewing conditions. A recent study in Ireland demonstrated that even with the advent of digital departments the majority of images are still viewed using viewing boxes. This investigation aimed to measure average viewing box brightness, percentage uniformity and ambient light levels in radiology and radiographer viewing areas and wards within three major Dublin hospitals. The results were compared with published recommendations by the World Health Organization and Commission of the European Communities. Following analysis of more than 4650 measurements, it was shown that mean values for average viewing box brightness for all departments failed to achieve recommended levels. Only one third of areas met the most lenient guideline for percentage uniformity. Ambient lighting was shown to be unacceptable for ward areas. For all three parameters, radiology areas generally fared best, with wards gaining the poorest scores. Following a 3 min cleaning regimen of viewing boxes, the average brightness and percentage uniformity were improved in 100% and 80%, respectively, of viewing boxes, but average brightness values remained below recommended levels. The importance of comprehensive quality assurance programmes for viewing boxes has been highlighted so that visualization of images is not reduced to sub-optimal levels. The need for consistent and more informative recommendations has been emphasized.
引用
收藏
页码:94 / 97
页数:4
相关论文
共 17 条
[1]   In the eyes of the beholder: what we see is not what we get [J].
Abdullah, BJJ ;
Ng, KH .
BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (884) :675-676
[2]   INCREASING CONTRAST WHEN VIEWING RADIOGRAPHIC IMAGES [J].
ABILDGAARD, A ;
NOTTHELLEN, JA .
RADIOLOGY, 1992, 185 (02) :475-478
[3]   THE INFLUENCE OF AMBIENT AND VIEWBOX LIGHT UPON VISUAL DETECTION OF LOW-CONTRAST TARGETS IN A RADIOGRAPH [J].
ALTER, AJ ;
KARGAS, GA ;
KARGAS, SA ;
CAMERON, JR ;
MCDERMOTT, JC .
INVESTIGATIVE RADIOLOGY, 1982, 17 (04) :402-406
[4]  
BAULM A, 1982, WHO TRAIN WORKSH QUA
[5]   Irish X-ray departments demonstrate varying levels of adherence to European guidelines on good radiographic technique [J].
Brennan, PC ;
Johnston, D .
BRITISH JOURNAL OF RADIOLOGY, 2002, 75 (891) :243-248
[6]  
*CEC, 1996, 16260 EUR EN CEC
[7]  
*CEC, 1997, RAD PROT
[8]  
*COMM EUR COMM, 1990, QUAL CRIT DIAGN RAD
[9]  
COONEY P, 1995, RADIAT PROT DOSIM, V57, P305
[10]   QUALITY ASSURANCE OF VIEWING BOXES - PROPOSAL FOR ESTABLISHING MINIMUM REQUIREMENTS AND RESULTS FROM A SPANISH QUALITY-CONTROL PROGRAM [J].
GUIBELALDE, E ;
VANO, E ;
LLORCA, AL .
BRITISH JOURNAL OF RADIOLOGY, 1990, 63 (751) :564-567