Low frequency fluctuations of a plasma in the central cell of the GAMMA10 tandem mirror have been observed with electrostatic probes (ESPs) installed at the peripheral region of the plasma. Typical plasma parameters for a hot ion mode operation are n(e)similar to2x10(12) cm(-3), T(i)similar to4 keV, T(e)similar to100 eV, B=4 kG, and r(p)=18 cm. Although the ESP is an effective tool to measure local plasma parameters and fluctuations, it can be damaged with the higher electron temperature. Here, a new visible light detector was introduced, which could measure the plasma fluctuations without contacting the plasma. The obtained results were compared with those of ESPs. It is found that the visible light detector is applicable when the electron temperature becomes much higher in the future experiment. (C) 2004 American Institute of Physics.