Determination of organochlorine pesticides and polychlorinated biphenyls in human serum using headspace solid-phase microextraction and gas chromatography-electron capture detection

被引:70
作者
Lopez, Raul
Goni, Fernando
Etxandia, Arsenio
Millan, Esmeralda
机构
[1] Univ Basque Country, Fac Quim, Dept Quim Aplicada, E-20080 San Sebastian, Spain
[2] Lab Salud Publ Guipzcoa, San Sebastian 20013, Spain
[3] Lab Salud Publ Vizcaya, Bilbao 48010, Spain
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2007年 / 846卷 / 1-2期
关键词
organochlorine pesticides (OCPs); polychlorinated biphenyls (PCBs); headspace solid-phase microextraction; GC-ECD; Plackett-Barman design; central composite design; human serum;
D O I
10.1016/j.jchromb.2006.09.009
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple procedure for the determination of organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs) in human serum using headspace solid-phase microextraction (HS-SPME) was developed. The analysis was carried out by gas chromatography (GC) equipped with electron capture detector (ECD). A 2(7-1) Plackett-Barman reduced factorial design for screening and a central composite design for optimizing the significant variables were applied. A 100 mu m PDMS fiber, 3/5 headspace ratio (3 ml in 5 ml vial), 85 C extraction temperature, 50 min extraction time, and 1 ml of acidic solution (pH 3) added to 1 ml of diluted serum (1:1) were chosen for the best response in HS extraction mode. The detection limits found were from 1 pg/ml (PCB 167) to 52 pg/ml (beta-HCH), the relative standard deviation for the procedure varied from 3% (PCB 52) to 12% (PCB 189) and the accuracy was checked by using validated solid-phase extraction (SPE) procedure. The method that avoids the use of clean-up steps and the hazardous solvents enabled reliable determinations of the OCPs and the PCBs except beta-HCH. The method was applied to the analysis of 33 human serum samples. The most abundant target compound was p-p'-DDE (range, 0.3-8.0 ng/ml; median value, 2.1 ng/ml). Among the PCBs the prevalent congeners were 138, 153 and 180. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:298 / 305
页数:8
相关论文
共 31 条
[1]   Optimization of solid-phase microextraction conditions using a response surface methodology to determine organochlorine pesticides in water by gas chromatography and electron-capture detection [J].
Aguilar, C ;
Peñalver, A ;
Pocurull, E ;
Ferré, J ;
Borrull, F ;
Marcé, RM .
JOURNAL OF CHROMATOGRAPHY A, 1999, 844 (1-2) :425-432
[2]  
[Anonymous], STAT CHEMOMETRICS AN
[3]   Assessment of reference values for polychlorinated biphenyl concentration in human blood [J].
Apostoli, P ;
Magoni, M ;
Bergonzi, R ;
Carasi, S ;
Indelicato, A ;
Scarcella, C ;
Donato, F .
CHEMOSPHERE, 2005, 61 (03) :413-421
[4]   Determination of fuel dialkyl ethers and BTEX in water using headspace solid-phase microextraction and gas chromatography-flame ionization detection [J].
Arambarri, I ;
Lasa, M ;
Garcia, R ;
Millán, E .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1033 (02) :193-203
[5]   Polychlorinated biphenyls in serum and time to pregnancy [J].
Axmon, A ;
Rylander, L ;
Strömberg, U ;
Jönsson, B ;
Nilsson-Ehle, P ;
Hagmar, L .
ENVIRONMENTAL RESEARCH, 2004, 96 (02) :186-195
[6]   New high-resolution mass spectrometric approach for the measurement of polychlorinated biphenyls and organochlorine pesticides in human serum [J].
Barr, JR ;
Maggio, VL ;
Barr, DB ;
Turner, WE ;
Sjödin, A ;
Sandau, CD ;
Pirkle, JL ;
Needham, LL ;
Patterson, DG .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 794 (01) :137-148
[7]   Persistent organochlorines in the serum of the non-occupationally exposed New Zealand population [J].
Bates, MN ;
Buckland, SJ ;
Garrett, N ;
Ellis, H ;
Needham, LL ;
Patterson, DG ;
Turner, WE ;
Russell, DG .
CHEMOSPHERE, 2004, 54 (10) :1431-1443
[8]   Gas chromatographic determination of selected pesticides in human serum by head-space solid-phase microextraction [J].
Beltran, J ;
Pitarch, E ;
Egea, S ;
López, FJ ;
Hernández, F .
CHROMATOGRAPHIA, 2001, 54 (11-12) :757-763
[9]  
Brereton R.G., 2003, DATA ANAL LAB CHEM P
[10]   Simple solid-phase extraction method for determination of polychlorinated biphenyls and selected organochlorine pesticides in human serum [J].
Conka, K ;
Drobná, B ;
Kocan, A ;
Petrík, J .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1084 (1-2) :33-38