Study on the noninvasive blood glucose measurement by diffusion reflectance NIR spectroscopy

被引:1
|
作者
Zhang, HY [1 ]
Song, LQ [1 ]
Wang, HY [1 ]
Wang, C [1 ]
Tang, YG [1 ]
机构
[1] Chinese Acad Sci, Changchun Inst Opt & Fine Mech & Phys, Changchun 130022, Peoples R China
来源
OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS: DIAGNOSTICS AND TREATMENT II , PTS 1 AND 2 | 2005年 / 5630卷
关键词
diffusion reflectance NIR spectroscopy; blood glucose; measurement; PLS;
D O I
10.1117/12.570433
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The noninvasive measurement of human blood glucose has been a hotspot for a long time to all clinical workers over the world. In this paper the noninvasive measurement of human blood glucose with diffusion reflectance NIR spectrum method is presented. The thumb fingertip, the palm and the wrist with vein are chosen for the collection of diffusion reflectance NIR spectroscopy from six different age healthy volunteers using Nexus-870 and its NIR fiber port smart accessory. The calibration model is set up in 7500similar to8500cm(-1) region that has the absorption of the glucose using Partial Least Squares (PLS) method with the first and second derivative spectral that had been smoothed and baseline corrected for single volunteer. The actual blood glucose value is determined by an ultraviolet spectrophotometer. The model with the spectrum obtained at the wrist is better than from other part for all volunteers, and it is much steadier with the second derivative pretreatment spectral than with the First derivative ones. The correlative coefficients are all over 0.93772; RMSECs are all less than 0.310 and the max differences are between -0.6mmo/L and +0.8mmo/L with the second derivative method. Some samples are kept for prediction with their own model. The differences are under 0.875529mmol/L.
引用
收藏
页码:460 / 467
页数:8
相关论文
共 50 条
  • [21] Study of Vis/NIR-spectroscopy measurement on acidity of yogurt
    He, Yong
    Feng, Shuijuan
    Wu, Di
    Li, Yiaoli
    FOURTH INTERNATIONAL CONFERENCE ON PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE, PTS 1 AND 2, 2006, 6047
  • [22] Noninvasive measurement of blood glucose based on optical sensing and internal standard method
    Saiki, Fujio
    Ishizawa, Hiroaki
    Muro, Akinobu
    Toba, Eiji
    PROCEEDINGS OF SICE ANNUAL CONFERENCE, VOLS 1-8, 2007, : 780 - 783
  • [23] TRANSFER AND COLLABORATIVE LEARNING METHOD FOR PERSONALIZED NONINVASIVE BLOOD GLUCOSE MEASUREMENT MODELING
    Liu, Weijie
    Huang, Anpeng
    Wang, Ping
    Yao, Hebin
    2019 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2019, : 1179 - 1183
  • [24] New optical method for noninvasive blood glucose measurement by optical ultrasonic modulation
    Zhu, Lili
    Lin, Jieqing
    Xie, Wenming
    Li, Hui
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS IV, 2010, 7845
  • [25] A new approach to noninvasive measurement of blood glucose using saliva analyzing system
    Mitsumori, M
    Yamaguchi, M
    Kano, Y
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 1767 - 1770
  • [26] Noninvasive NIR spectroscopy to verify endpoint temperature of kamaboko gel
    Uddin, M
    Okazaki, E
    Ahmad, MU
    Fukuda, Y
    Tanaka, M
    LWT-FOOD SCIENCE AND TECHNOLOGY, 2005, 38 (08) : 809 - 814
  • [27] Determination of Glucose Content with a Concentration within the Physiological Range by FT-NIR Spectroscopy in a Trans-Reflectance Mode
    Rondonuwu, Ferdy S.
    Setiawan, Andreas
    14TH JOINT CONFERENCE ON CHEMISTRY 2019, 2020, 2237
  • [28] Noninvasive Glucose Monitor Using Dielectric Spectroscopy
    Buehler, Lauren A.
    Balasubramanian, Vignesh
    Baskerville, Scott
    Bailey, Ryan
    McCarthy, Keira
    Rippen, Marc
    Bena, James F.
    Lansang, Maria Cecilia
    ENDOCRINE PRACTICE, 2022, 28 (02) : 142 - 147
  • [29] FT-NIR diffuse reflectance spectroscopy for kiwifruit firmness detection
    Xiaping Fu
    Yibin Ying
    Huishan Lu
    Huirong Xu
    Haiyan Yu
    Sensing and Instrumentation for Food Quality and Safety, 2007, 1 (1): : 29 - 35
  • [30] Noninvasive measurement of cerebral blood flow in adults using near-infrared spectroscopy and indocyanine green: A pilot study
    Gora, F
    Shinde, S
    Elwell, CE
    Goldstone, JC
    Cope, M
    Delpy, DT
    Smith, M
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2002, 14 (03) : 218 - 222