Monitoring of heparin therapy beyond the anti-Xa activity assay: Evaluation of a thrombin generation assay

被引:2
|
作者
Vermeiren, Pauline [1 ]
Vandevelde, Arne [1 ,2 ]
Peperstraete, Harlinde [3 ]
Devreese, Katrien M. J. [1 ,2 ]
机构
[1] Ghent Univ Hosp, Coagulat Lab, Dept Lab Med, Ghent, Belgium
[2] Univ Ghent, Dept Diagnost Sci, Ghent, Belgium
[3] Ghent Univ Hosp, Dept Intens Care Med, Ghent, Belgium
关键词
blood coagulation tests; heparin; reference values; thrombin; MOLECULAR-WEIGHT HEPARIN; UNFRACTIONATED HEPARIN; ANTICOAGULANT-THERAPY; VARIABILITY; PROTEINS; BINDING;
D O I
10.1111/ijlh.13836
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Global coagulation assays may be of added value to the anti-Xa assay for monitoring heparin therapy. Unlike most testing methods, the thrombin generation assay ( TGA) has the ability to assess the overall function of the hemostatic system, which provides information on the anticoagulation status of patients. We compared the TGA, measured with ST Genesia (R) STG-DrugScreen (R) reagent, with the anti-Xa assay for monitoring heparin therapy in inflammatory and non-inflammatory patients. We also determined reference values for STG-DrugScreen (R) thrombin generation (TG) parameters. Methods: Reference values were determined on 120 healthy donors. Furthermore, a spiking experiment with unfractionated heparin (UFH) and low molecular weight heparin (LMWH) was performed, and samples of patients receiving UFH or LMWH were analyzed with ST Genesia (R) and the anti-Xa assay. Results: High discrepancy between TG parameters and anti-Xa activity was observed for low LMWH anti-Xa levels. TG parameters were affected in 36/46 (time to peak) to 42/46 (peak height) patients during UFH therapy with sub-target anti-Xa activity levels. Conclusion: TGA seems insufficiently sensitive for low concentrations of LMWH. There may be an added value of the TGA for monitoring UFH in so-called heparin-resistant patients. Therefore, the TGA has the potential to be introduced as an additional tool for monitoring heparin therapy.
引用
收藏
页码:785 / 795
页数:11
相关论文
共 50 条
  • [41] APTT therapeutic range for monitoring unfractionated heparin therapy. Significant impact of the anti-Xa reagent used for correlation: COMMENT
    Kovacs, Michael J.
    Lazo-Langner, Alejandro
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2021, 19 (08) : 2089 - 2089
  • [42] Effects of factor VIII levels on the APTT and anti-Xa activity under a therapeutic dose of heparin
    Mana Mitsuguro
    Akira Okamoto
    Yoshie Shironouchi
    Michitaka Sano
    Shigeki Miyata
    Reiko Neki
    Tatsuya Araki
    Takayoshi Hamamoto
    Jun Yoshimatsu
    Toshiyuki Miyata
    International Journal of Hematology, 2015, 101 : 119 - 125
  • [43] Evaluation of Anti-Xa and Activated Partial Thromboplastin Time Monitoring of Heparin in Adult Patients Receiving Extracorporeal Membrane Oxygenation Support
    Arnouk, Serena
    Altshuler, Diana
    Lewis, Tyler C.
    Merchan, Cristian
    Smith, Deane E., III
    Toy, Bridget
    Zakhary, Bishoy
    Papadopoulos, John
    ASAIO JOURNAL, 2020, 66 (03) : 300 - 306
  • [44] Effects of factor VIII levels on the APTT and anti-Xa activity under a therapeutic dose of heparin
    Mitsuguro, Mana
    Okamoto, Akira
    Shironouchi, Yoshie
    Sano, Michitaka
    Miyata, Shigeki
    Neki, Reiko
    Araki, Tatsuya
    Hamamoto, Takayoshi
    Yoshimatsu, Jun
    Miyata, Toshiyuki
    INTERNATIONAL JOURNAL OF HEMATOLOGY, 2015, 101 (02) : 119 - 125
  • [45] Interference of oral anti-Xa anticoagulants during monitoring of unfractionated heparin treatments: practical and future attitudes
    Melicine, Sophie
    Maucorps, Laure
    Eschwege, Valerie
    Carre, Julie
    Helley, Dominique
    Gouin-Thibault, Isabelle
    Gendron, Nicolas
    Nedelec-Gac, Fabienne
    Mauge, Laetitia
    ANNALES DE BIOLOGIE CLINIQUE, 2024, 82 (02) : 129 - 138
  • [46] Anticoagulation Monitoring During Extracorporeal Membrane Oxygenation: Is Anti-Factor Xa Assay (Heparin Level) a Better Test?
    Trung Nguyen
    Musick, Matthew
    Teruya, Jun
    PEDIATRIC CRITICAL CARE MEDICINE, 2014, 15 (02) : 178 - 179
  • [47] Monitoring unfractionated heparin therapy in dogs by measuring thrombin generation
    Allegret, Virginie
    Dunn, Marilyn
    Bedard, Christian
    VETERINARY CLINICAL PATHOLOGY, 2011, 40 (01) : 24 - 31
  • [48] Anti-Xa level monitoring of low-molecular-weight heparin during intermittent venovenous hemofiltration
    Xu, Lengnan
    Sun, Ying
    Wang, Songlan
    Li, Chuanbao
    Mao, Yonghui
    ANNALS OF HEMATOLOGY, 2023, 102 (08) : 2251 - 2256
  • [49] Development and evaluation of PEGylated Enoxaparin: A novel approach for enhanced anti-Xa activity
    Choubey, Anupam Kumar
    Dora, Chander Parkash
    Bhatt, Tara Dutt
    Gill, Manjinder Singh
    Suresh, Sarasija
    BIOORGANIC CHEMISTRY, 2014, 54 : 1 - 6
  • [50] Discordant Partial Thromboplastin Time (PTT) vs Anti-Xa Heparin Activity: Using the Baseline PTT to Improve Concordance
    Khan, Jenna
    Chandler, Wayne L.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2019, 151 (04) : 424 - 432