Initial Clinical Experience With the Modified Zenith "Pro-Form" TX2 Thoracic Endograft

被引:24
作者
Melissano, Germano [1 ]
Civilini, Efrem [1 ]
Bertoglio, Luca [1 ]
Logaldo, Davide [1 ]
Chiesa, Roberto [1 ]
机构
[1] Univ Vita Salute San Raffaele, Sci Inst H San Raffaele, Dept Vasc Surg, Milan, Italy
关键词
thoracic aortic aneurysm; thoracic endovascular aortic repair; thoracic aortic dissection; thoracic stent-graft; STENT-GRAFT; AORTIC-ANEURYSMS; COLLAPSE; REPAIR; ARCH; SYSTEM; TRIAL;
D O I
10.1583/10-3061.1
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To assess the safety and efficacy of thoracic aortic endovascular repair (TEVAR) with the newly introduced Zenith TX2 thoracic stent-graft with Pro-Form. Methods: From March 2009 to present, the Zenith TX2 with Pro-Form was used to treat 27 patients (23 men; median age 65 years, range 22-77) suffering from descending thoracic aortic disease: 20 degenerative aneurysms, 3 chronic type B dissections, 2 type I endoleaks following previous endograft repair, 1 aortic ulcer, and 1 traumatic isthmic rupture. According to Ishimaru's classification, the distribution of the proximal landing zone was zone 0 in 4 cases, zone 1 in 2 cases, zone 2 in 9 cases, zone 3 in 7 cases, and zone 4 in 5 cases. One aneurysm distally involved the thoracoabdominal aorta. An acutely angulated (<90 degrees) proximal landing zone was found in 9 patients. Results: The device was safely and effectively deployed in all cases, with no problems during sheath retrieval. The postoperative course was free from major complications in all cases, and there was no perioperative mortality. Postoperative morbidity included respiratory failure in 1 case, transient acute renal failure in 3 cases, and post-implantation syndrome in 2 cases. Postoperative computed tomography at 1 and 6 months confirmed 100% clinical success with the absence of device-related complications. No type I endoleak was documented. The proximal sealing stent fitted well with the aortic profile in all cases except one, in which malapposition was seen in a severely angulated aorta at 6-month follow-up. Conclusion: Based on this preliminary experience, the TX2 thoracic stent-graft with Pro-Form can be safely and effectively deployed to satisfactorily repair thoracic aortic pathology, including lesions in the arch. Stent-graft conformance to the aorta was excellent even in cases with unfavorable anatomy. These encouraging results will need to be confirmed in larger series with larger follow-up. J Endovasc Ther. 2010;17:463-470
引用
收藏
页码:463 / 470
页数:8
相关论文
共 26 条
[1]   Acute angulation of the aortic arch predisposes a patient to ascending aortic dilatation and aortic regurgitation late after the arterial switch operation for transposition of the great arteries [J].
Agnoletti, Gabriella ;
Ou, Phalla ;
Celermajer, David S. ;
Boudjemline, Younes ;
Marini, Davide ;
Bonnet, Damien ;
Aggoun, Yacine .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 135 (03) :568-572
[2]   Factors favoring stent-graft collapse after thoracic endovascular aortic repair [J].
Canaud, Ludovic ;
Alric, Pierre ;
Desgranges, Pascal ;
Marzelle, Jean ;
Marty-Ane, Charles ;
Becquemin, Jean-Pierre .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (05) :1153-1157
[3]  
Cao P, 2009, J CARDIOVASC SURG, V50, P483
[4]   Identifying and grading factors that modify the outcome of endovascular aortic aneurysm repair [J].
Chaikof, EL ;
Fillinger, MF ;
Matsumura, JS ;
Rutherford, RB ;
White, GH ;
Blankensteijn, JD ;
Bernhard, VM ;
Harris, PL ;
Kent, KC ;
May, J ;
Veith, FJ ;
Zarins, CK .
JOURNAL OF VASCULAR SURGERY, 2002, 35 (05) :1061-1066
[5]   Fenestrated and branched stent-grafts for thoracoabdominal, pararenal and juxtarenal aortic aneurysm repair [J].
Chuter, Timothy A. M. .
SEMINARS IN VASCULAR SURGERY, 2007, 20 (02) :90-96
[6]   Thoracic aorta endografts: Variations in practice among medical specialists [J].
Eggebrecht, Holger ;
Pamler, Reinhard ;
Zipfel, Burkhart ;
Herold, Ulf ;
Chavan, Ajay ;
Rehders, Tim C. ;
Nienaber, Christoph A. ;
Hetzer, Roland ;
Jakob, Heinz G. ;
Mehta, Rajendra H. ;
Erbel, Raimund .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 68 (06) :843-852
[7]   Pivotal results of the Medtronic Vascular Talent Thoracic Stent Graft System: The VALOR trial [J].
Fairman, Ronald M. ;
Criado, Frank ;
Farber, Mark ;
Kwolek, Christopher ;
Mehta, Manish ;
White, Rodney ;
Lee, Anthony ;
Tuchek, J. Michael .
JOURNAL OF VASCULAR SURGERY, 2008, 48 (03) :546-554
[8]   Thoracic endovascular stent graft with a bird's beak sign [J].
Fayad, Ashraf .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2008, 55 (11) :785-786
[9]   Magnitude and Direction of Pulsatile Displacement Forces Acting on Thoracic Aortic Endografts [J].
Figueroa, C. Alberto ;
Taylor, Charles A. ;
Chiou, Allen J. ;
Yeh, Victoria ;
Zarins, Christopher K. .
JOURNAL OF ENDOVASCULAR THERAPY, 2009, 16 (03) :350-358
[10]   Staged Proximal Deployment of the Zenith TX2 Thoracic Stent-Graft: A Novel Technique to Improve Conformance to the Aortic Arch [J].
Kolbel, Tilo ;
Resch, Timothy A. ;
Dias, Nuno ;
Bjorses, Katarina ;
Sonesson, Bjorn ;
Malina, Martin .
JOURNAL OF ENDOVASCULAR THERAPY, 2009, 16 (05) :598-602