High Resolution, Full Field-of-View, Whole Body Photon-Counting Detector CT: System Assessment and Initial Experience

被引:6
作者
Rajendran, Kishore [1 ]
Marsh, Jeffrey [1 ]
Petersilka, Martin [2 ]
Henning, Andre [2 ]
Shanblatt, Elisabeth [3 ]
Schmidt, Bernhard [2 ]
Flohr, Thomas [2 ]
Fletcher, Joel [1 ]
McCollough, Cynthia [1 ]
Leng, Shuai [1 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[2] Siemens Healthcare GmbH, Forchheim, Germany
[3] Siemens Med Solut USA Inc, Malvern, PA USA
来源
MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING | 2021年 / 11595卷
基金
美国国家卫生研究院;
关键词
Photon-counting detectors; X-ray computed tomography; ultra-high spatial resolution; multi-energy CT; image quality; COMPUTED-TOMOGRAPHY;
D O I
10.1117/12.2581944
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Computed tomography (CT) using photon-counting detectors (PCD) offers dose-efficient ultra-high-resolution imaging, high iodine contrast-to-noise ratio, multi-energy and material decomposition capabilities. We have previously demonstrated the potential benefits of PCD-CT using phantoms, cadavers, and human studies on a prototype PCD-CT system. This system, however, had several limitations in terms of scan field-of-view (FOV) and longitudinal coverage. Recently, a full FOV (50 cm) PCD-CT system with wider longitudinal coverage and higher spatial resolution (0.15 mm detector pixels) has been installed in our lab capable of human scanning at clinical dose and dose rate. In this work, we share our initial experience of the new PCD-CT system and compare its performance with a state-of-the-art 3rd generation dual-source CT scanner. Basic image quality was assessed using an ACR CT accreditation phantom, high-resolution performance using an anthropomorphic head phantom, and multi-energy and material decomposition performance using a multi-energy CT phantom containing various concentrations of iodine and hydroxyapatite. Finally, we demonstrate the feasibility of high-resolution, full FOV PCD-CT imaging for improved delineation of anatomical and pathological features in a patient with pulmonary nodules.
引用
收藏
页数:6
相关论文
共 50 条
[41]   Technical feasibility proof for high-resolution low-dose photon-counting CT of the breast [J].
Willi A. Kalender ;
Daniel Kolditz ;
Christian Steiding ;
Veikko Ruth ;
Ferdinand Lück ;
Ann-Christin Rößler ;
Evelyn Wenkel .
European Radiology, 2017, 27 :1081-1086
[42]   Ultra-High-Resolution Photon-Counting Detector CT Benefits Visualization of Abdominal Arteries: A Comparison to Standard-Reconstruction [J].
Zhang, Huan ;
Xing, Yue ;
Wang, Lingyun ;
Hu, Yangfan ;
Xu, Zhihan ;
Chen, Haoda ;
Lu, Junjie ;
Yang, Jiarui ;
Ding, Bei ;
Hu, Weiguo ;
Zhong, Jingyu .
JOURNAL OF IMAGING INFORMATICS IN MEDICINE, 2025, 38 (03) :1891-1903
[43]   Ultra-high-resolution photon-counting detector CT in evaluating coronary stent patency: a comparison to invasive coronary angiography [J].
Hagar, Muhammad Taha ;
Soschynski, Martin ;
Saffar, Ruben ;
Molina-Fuentes, Moises Felipe ;
Weiss, Jakob ;
Rau, Alexander ;
Schuppert, Christopher ;
Ruile, Philipp ;
Faby, Sebastian ;
Schibilsky, David ;
von zur Muehlen, Constantin ;
Schlett, Christopher L. ;
Bamberg, Fabian ;
Krauss, Tobias .
EUROPEAN RADIOLOGY, 2024, 34 (07) :4273-4283
[44]   Lung microvasculopathy in chronic thromboembolic pulmonary hypertension: high-resolution findings with photon-counting detector CT in 29 patients [J].
Remy-Jardin, Martine ;
Duhamel, Alain ;
Delobelle, Marie ;
Bervar, Jean-Francois ;
Flohr, Thomas ;
Remy, Jacques .
EUROPEAN RADIOLOGY, 2025,
[45]   A Blooming correction technique for improved vasa vasorum detection using an ultra-high-resolution photon-counting detector CT [J].
Marsh, Jeffrey, Jr. ;
Rajendran, Kishore ;
Tao, Shengzhen ;
Vercnocke, Andrew ;
Anderson, Jill ;
Leng, Shuai ;
Ritman, Erik ;
McCollough, Cynthia .
MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
[46]   Bone Mineral Density Assessment Using Spectral Topograms From a Clinical Photon-Counting Detector CT System: A Phantom Evaluation [J].
Moser, Lukas J. ;
Pitteloud, Janique ;
Mergen, Victor ;
Frey, Diana ;
Nowak, Tristan ;
Distler, Oliver ;
Eberhard, Matthias ;
Alkadhi, Hatem .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 222 (02)
[47]   Assessment of a photon-counting detector for a dual-energy C-arm angiographic system [J].
Ahmad, Moiz ;
Fahrig, Rebecca ;
Pung, Leland ;
Spahn, Martin ;
Koester, Niko S. ;
Reitz, Silke ;
Moore, Teri ;
Choi, Jang-Hwan ;
Hinshaw, Waldo ;
Xia, Yan ;
Mueller, Kerstin .
MEDICAL PHYSICS, 2017, 44 (11) :5938-5948
[48]   Comparison of Radiation Dose and Image Quality of Pediatric High-Resolution Chest CT Between Photon-Counting Detector CT and Energy-Integrated Detector CT: A Matched Study [J].
Siegel, Marilyn J. ;
Bugenhagen, Scott M. ;
Sanchez, Adrian ;
Kim, Stacy ;
Abadia, Andres ;
Ramirez-Giraldo, Juan C. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2023, 221 (03) :363-371
[49]   Ultra-high Versus Standard Resolution Photon-Counting Detector CT Angiography for Imaging of Femoral Stents in a Cadaveric Perfusion Model [J].
Hartung, Viktor ;
Hendel, Robin ;
Huflage, Henner ;
Augustin, Anne Marie ;
Grunz, Jan-Peter ;
Kleefeldt, Florian ;
Peter, Dominik ;
Lichthardt, Sven ;
Erguen, Sueleyman ;
Bley, Thorsten Alexander ;
Gruschwitz, Philipp .
ACADEMIC RADIOLOGY, 2025, 32 (01) :556-564
[50]   Photon-counting detector CT reduces the rate of referrals to invasive coronary angiography as compared to CT with whole heart coverage energy-integrating detector [J].
Simon, Judit ;
Hrenko, Aron ;
Kerkovits, Nora Melinda ;
Nagy, Kristof ;
Vertes, Miklos ;
Balogh, Hanna ;
Nagy, Norbert ;
Munkacsi, Tamas ;
Emrich, Tilman ;
Varga-Szemes, Akos ;
Boussoussou, Melinda ;
Vattay, Borbala ;
Vecsey-Nagy, Milan ;
Kolossvary, Marton ;
Szilveszter, Balint ;
Merkely, Bela ;
Maurovich-Horvat, Pal .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2024, 18 (01) :69-74