High Resolution, Full Field-of-View, Whole Body Photon-Counting Detector CT: System Assessment and Initial Experience

被引:6
作者
Rajendran, Kishore [1 ]
Marsh, Jeffrey [1 ]
Petersilka, Martin [2 ]
Henning, Andre [2 ]
Shanblatt, Elisabeth [3 ]
Schmidt, Bernhard [2 ]
Flohr, Thomas [2 ]
Fletcher, Joel [1 ]
McCollough, Cynthia [1 ]
Leng, Shuai [1 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[2] Siemens Healthcare GmbH, Forchheim, Germany
[3] Siemens Med Solut USA Inc, Malvern, PA USA
来源
MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING | 2021年 / 11595卷
基金
美国国家卫生研究院;
关键词
Photon-counting detectors; X-ray computed tomography; ultra-high spatial resolution; multi-energy CT; image quality; COMPUTED-TOMOGRAPHY;
D O I
10.1117/12.2581944
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Computed tomography (CT) using photon-counting detectors (PCD) offers dose-efficient ultra-high-resolution imaging, high iodine contrast-to-noise ratio, multi-energy and material decomposition capabilities. We have previously demonstrated the potential benefits of PCD-CT using phantoms, cadavers, and human studies on a prototype PCD-CT system. This system, however, had several limitations in terms of scan field-of-view (FOV) and longitudinal coverage. Recently, a full FOV (50 cm) PCD-CT system with wider longitudinal coverage and higher spatial resolution (0.15 mm detector pixels) has been installed in our lab capable of human scanning at clinical dose and dose rate. In this work, we share our initial experience of the new PCD-CT system and compare its performance with a state-of-the-art 3rd generation dual-source CT scanner. Basic image quality was assessed using an ACR CT accreditation phantom, high-resolution performance using an anthropomorphic head phantom, and multi-energy and material decomposition performance using a multi-energy CT phantom containing various concentrations of iodine and hydroxyapatite. Finally, we demonstrate the feasibility of high-resolution, full FOV PCD-CT imaging for improved delineation of anatomical and pathological features in a patient with pulmonary nodules.
引用
收藏
页数:6
相关论文
共 50 条
[31]   Spectral photon-counting CT imaging of colorectal peritoneal metastases: initial experience in rats [J].
Thivolet, Arnaud ;
Si-Mohamed, Salim ;
Bonnot, Pierre-Emmanuel ;
Blanchet, Christophe ;
Kepenekian, Vahan ;
Boussel, Loic ;
Douek, Philippe ;
Rousset, Pascal .
SCIENTIFIC REPORTS, 2020, 10 (01)
[32]   One-Stop multienergy pancreatic dynamic volume perfusion imaging using photon-counting detector CT: Initial experience [J].
Yang, Yanzhao ;
Zhu, Naiyi ;
Lin, Huimin ;
Xu, Zhihan ;
Chang, Rui ;
Chai, Weimin ;
Yan, Fuhua .
EUROPEAN JOURNAL OF RADIOLOGY, 2025, 190
[33]   Low-dose performance of a whole-body research photon-counting CT scanner [J].
Yu, Zhicong ;
Leng, Shuai ;
Kappler, Steffen ;
Hahn, Katharina ;
Li, Zhoubo ;
Halaweish, Ahmed F. ;
Henning, Andre ;
Ritman, Erik L. ;
McCollough, Cynthia H. .
MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
[34]   Low-dose Ultra-high-resolution Photon-Counting Detector CT for Visceral Artery CT Angiography: A Preliminary Study [J].
Wang, Lingyun ;
Hu, Yangfan ;
Zhong, Jingyu ;
Yue, Xing ;
Xu, Zhihan ;
Ding, Bei ;
Chu, Jingshen ;
Yan, Fuhua ;
Yao, Weiwu ;
Zhang, Huan ;
Hu, Weiguo .
ACADEMIC RADIOLOGY, 2024, 31 (12) :5087-5099
[35]   A Universal Protocol for Abdominal CT Examinations Performed on a Photon-Counting Detector CT System A Feasibility Study [J].
Zhou, Wei ;
Michalak, Gregory J. ;
Weaver, Jayse M. ;
Gong, Hao ;
Yu, Lifeng ;
McCollough, Cynthia H. ;
Leng, Shuai .
INVESTIGATIVE RADIOLOGY, 2020, 55 (04) :226-232
[36]   Assessment of visibility of bone structures in the wrist using normal and half of the radiation dose with photon-counting detector CT [J].
Booij, Ronald ;
Kammerling, Nina F. ;
Oei, Edwin H. G. ;
Persson, Anders ;
Tesselaar, Erik .
EUROPEAN JOURNAL OF RADIOLOGY, 2023, 159
[37]   Effects of Detector Sampling on Noise Reduction in Clinical Photon-Counting Whole-Body Computed Tomography [J].
Klein, Laura ;
Dorn, Sabrina ;
Amato, Carlo ;
Heinze, Sarah ;
Uhrig, Monika ;
Schlemmer, Heinz-Peter ;
Kachelriess, Marc ;
Sawall, Stefan .
INVESTIGATIVE RADIOLOGY, 2020, 55 (02) :111-119
[38]   Spectral Shaping Via Tin Prefiltration in Ultra-High-Resolution Photon-Counting and Energy-Integrating Detector CT of the Temporal Bone [J].
Grunz, Jan-Peter ;
Heidenreich, Julius Frederik ;
Lennartz, Simon ;
Weighardt, Jens Philipp ;
Bley, Thorsten Alexander ;
Erguen, Sueleyman ;
Petritsch, Bernhard ;
Huflage, Henner .
INVESTIGATIVE RADIOLOGY, 2022, 57 (12) :819-825
[39]   High-Resolution Head CTA: A Prospective Patient Study Comparing Image Quality of Photon-Counting Detector CT and Energy-Integrating Detector CT [J].
Diehn, Felix E. ;
Zhou, Zhongxing ;
Thorne, Jamison E. ;
Campeau, Norbert G. ;
Nagelschneider, Alex A. ;
Eckel, Laurence J. ;
Benson, John C. ;
Madhavan, Ajay A. ;
Bathla, Girish ;
Lehman, Vance T. ;
Huber, Nathan R. ;
Baffour, Francis ;
Fletcher, Joel G. ;
McCollough, Cynthia H. ;
Yu, Lifeng .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2024, 45 (10) :1441-1449
[40]   Technical feasibility proof for high-resolution low-dose photon-counting CT of the breast [J].
Kalender, Willi A. ;
Kolditz, Daniel ;
Steiding, Christian ;
Ruth, Veikko ;
Lueck, Ferdinand ;
Rossler, Ann-Christin ;
Wenkel, Evelyn .
EUROPEAN RADIOLOGY, 2017, 27 (03) :1081-1086