High Resolution, Full Field-of-View, Whole Body Photon-Counting Detector CT: System Assessment and Initial Experience

被引:6
作者
Rajendran, Kishore [1 ]
Marsh, Jeffrey [1 ]
Petersilka, Martin [2 ]
Henning, Andre [2 ]
Shanblatt, Elisabeth [3 ]
Schmidt, Bernhard [2 ]
Flohr, Thomas [2 ]
Fletcher, Joel [1 ]
McCollough, Cynthia [1 ]
Leng, Shuai [1 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[2] Siemens Healthcare GmbH, Forchheim, Germany
[3] Siemens Med Solut USA Inc, Malvern, PA USA
来源
MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING | 2021年 / 11595卷
基金
美国国家卫生研究院;
关键词
Photon-counting detectors; X-ray computed tomography; ultra-high spatial resolution; multi-energy CT; image quality; COMPUTED-TOMOGRAPHY;
D O I
10.1117/12.2581944
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Computed tomography (CT) using photon-counting detectors (PCD) offers dose-efficient ultra-high-resolution imaging, high iodine contrast-to-noise ratio, multi-energy and material decomposition capabilities. We have previously demonstrated the potential benefits of PCD-CT using phantoms, cadavers, and human studies on a prototype PCD-CT system. This system, however, had several limitations in terms of scan field-of-view (FOV) and longitudinal coverage. Recently, a full FOV (50 cm) PCD-CT system with wider longitudinal coverage and higher spatial resolution (0.15 mm detector pixels) has been installed in our lab capable of human scanning at clinical dose and dose rate. In this work, we share our initial experience of the new PCD-CT system and compare its performance with a state-of-the-art 3rd generation dual-source CT scanner. Basic image quality was assessed using an ACR CT accreditation phantom, high-resolution performance using an anthropomorphic head phantom, and multi-energy and material decomposition performance using a multi-energy CT phantom containing various concentrations of iodine and hydroxyapatite. Finally, we demonstrate the feasibility of high-resolution, full FOV PCD-CT imaging for improved delineation of anatomical and pathological features in a patient with pulmonary nodules.
引用
收藏
页数:6
相关论文
共 16 条
[1]   High-Resolution Chest Computed Tomography Imaging of the Lungs Impact of 1024 Matrix Reconstruction and Photon-Counting Detector Computed Tomography [J].
Bartlett, David J. ;
Koo, Chi Wan ;
Bartholmai, Brian J. ;
Rajendran, Kishore ;
Weaver, Jayse M. ;
Halaweish, Ahmed E. ;
Leng, Shuai ;
McCollough, Cynthia H. ;
Fletcher, Joel G. .
INVESTIGATIVE RADIOLOGY, 2019, 54 (03) :129-137
[2]   Novel ultrahigh resolution data acquisition and image reconstruction for multi-detector row CT [J].
Flohr, T. G. ;
Stierstorfer, K. ;
Suess, C. ;
Primak, A. N. ;
McCollough, C. H. .
MEDICAL PHYSICS, 2007, 34 (05) :1712-1723
[3]   Feasibility of unconstrained three-material decomposition: imaging an excised human heart using a prototype silicon photon-counting CT detector [J].
Gronberg, Fredrik ;
Lundberg, Johan ;
Sjolin, Martin ;
Persson, Mats ;
Bujila, Robert ;
Bornefalk, Hans ;
Almqvist, Hakan ;
Holmin, Staffan ;
Danielsson, Mats .
EUROPEAN RADIOLOGY, 2020, 30 (11) :5904-5912
[4]   Human Imaging With Photon Counting-Based Computed Tomography at Clinical Dose Levels: Contrast-to-Noise Ratio and Cadaver Studies [J].
Gutjahr, Ralf ;
Halaweish, Ahmed F. ;
Yu, Zhicong ;
Leng, Shuai ;
Yu, Lifeng ;
Li, Zhoubo ;
Jorgensen, Steven M. ;
Ritman, Erik L. ;
Kappler, Steffen ;
McCollough, Cynthia H. .
INVESTIGATIVE RADIOLOGY, 2016, 51 (07) :421-429
[5]   Effects of Detector Sampling on Noise Reduction in Clinical Photon-Counting Whole-Body Computed Tomography [J].
Klein, Laura ;
Dorn, Sabrina ;
Amato, Carlo ;
Heinze, Sarah ;
Uhrig, Monika ;
Schlemmer, Heinz-Peter ;
Kachelriess, Marc ;
Sawall, Stefan .
INVESTIGATIVE RADIOLOGY, 2020, 55 (02) :111-119
[6]   Photon-counting Detector CT: System Design and Clinical Applications of an Emerging Technology [J].
Leng, Shuai ;
Bruesewitz, Michael ;
Tao, Shengzhen ;
Rajendran, Kishore ;
Halaweish, Ahmed F. ;
Campeau, Norbert G. ;
Fletcher, Joel G. ;
McCollough, Cynthia H. .
RADIOGRAPHICS, 2019, 39 (03) :729-743
[7]   Dose-efficient ultrahigh-resolution scan mode using a photon counting detector computed tomography system [J].
Leng, Shuai ;
Yu, Zhicong ;
Halaweish, Ahmed ;
Kappler, Steffen ;
Hahn, Katharina ;
Henning, Andre ;
Li, Zhoubo ;
Lane, John ;
Levin, David L. ;
Jorgensen, Steven ;
Ritman, Erik ;
McCollough, Cynthia .
JOURNAL OF MEDICAL IMAGING, 2016, 3 (04)
[8]   Spectral Photon-counting CT: Initial Experience with Dual-Contrast Agent K-Edge Colonography [J].
Muenzel, Daniela ;
Bar-Ness, Daniel ;
Roessl, Ewald ;
Blevis, Ira ;
Bartels, Matthias ;
Fingerle, Alexander A. ;
Ruschke, Stefan ;
Coulon, Philippe ;
Daerr, Heiner ;
Kopp, Felix K. ;
Brendel, Bernhard ;
Thran, Axel ;
Rokni, Michal ;
Herzen, Julia ;
Boussel, Loic ;
Pfeiffer, Franz ;
Proksa, Roland ;
Rummeny, Ernst J. ;
Douek, Philippe ;
Noel, Peter B. .
RADIOLOGY, 2017, 283 (03) :722-727
[9]   Dose Efficiency of Quarter-Millimeter Photon-Counting Computed Tomography First-in-Human Results [J].
Pourmorteza, Amir ;
Symons, Rolf ;
Henning, Andre ;
Ulzheimer, Stefan ;
Bluemke, David A. .
INVESTIGATIVE RADIOLOGY, 2018, 53 (06) :365-372
[10]   Quantitative Knee Arthrography in a Large Animal Model of Osteoarthritis Using Photon-Counting Detector CT [J].
Rajendran, Kishore ;
Murthy, Naveen S. ;
Frick, Matthew A. ;
Tao, Shengzhen ;
Unger, Mark D. ;
LaVallee, Katherine T. ;
Larson, Nicholas B. ;
Leng, Shuai ;
Maus, Timothy P. ;
McCollough, Cynthia H. .
INVESTIGATIVE RADIOLOGY, 2020, 55 (06) :349-356