Experimental study of the effect of shallow groundwater table on soil thermal properties

被引:2
作者
Jiang, Jianmei [1 ]
Zhao, Lin [1 ,2 ]
Zeng, Yijian [3 ]
Zhai, Zhe [2 ]
机构
[1] Tianjin Univ, Sch Chem Engn, Tianjin 300072, Peoples R China
[2] Tianjin Univ, Sch Environm Sci & Engn, Tianjin 300072, Peoples R China
[3] Univ Twente, ITC Fac, Water Resources Dept, NL-7514 AE Enschede, Netherlands
关键词
soil temperature; thermal property; ground-water table depth; evaporation; WATER-VAPOR; HEAT-TRANSPORT; LIQUID WATER; NEEDLE PROBE; CONDUCTIVITY; TEMPERATURE; ENHANCEMENT; EVAPORATION; MODEL; ZONE;
D O I
10.1007/s11707-015-0502-y
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
In plains areas with semi-arid climates, shallow groundwater is one of the important factors affecting soil thermal properties. In this study, soil temperature and water content were measured when groundwater tables reached 10 cm, 30 cm, and 60 cm depths (Experiment I, II, and III) by using sensors embedded at depths of 5 cm, 10 cm, 20 cm, and 30 cm for 5 days. Soil thermal properties were analyzed based on the experimental data using the simplified de Vries model. Results show that soil water content and temperature have fluctuations that coincide with the 24 h diurnal cycle, and the amplitude of these fluctuations decreased with the increase in groundwater table depth. The amplitude of soil water content at 5 cm depth decreased from 0.025 m(3).m(-3) in Experiment II to 0.01 m(3).m(-3) in Experiment III. Moreover, it should be noted that the soil temperature in Experiment III gradually went up with the lowest value increasing from 26.0 degrees C to 28.8 degrees C. By contrast, the trends were not evident in Experiments I and II. Results indicate that shallow groundwater has a "cooling" effect on soil in the capillary zone. In addition, calculated values of thermal conductivity and heat capacity declined with the increasing depth of the groundwater table, which is consistent with experimental results. The thermal conductivity was stable at a value of 2.3W.cm(-1)K(-1) in Experiment I. The average values of thermal conductivity at different soil depths in Experiment II were 1.82W.cm(-1).K-1, 2.15W.cm(-1).K-1, and 2.21W.cm(-1).K-1, which were always higher than that in Experiment III.
引用
收藏
页码:29 / 37
页数:9
相关论文
共 42 条
  • [1] [Anonymous], 2005, HYDRUS 1D SOFTWARE P
  • [2] Thermal conductivity of soils and rocks from the Melbourne (Australia) regiond
    Barry-Macaulay, D.
    Bouazza, A.
    Singh, R. M.
    Wang, B.
    Ranjith, P. G.
    [J]. ENGINEERING GEOLOGY, 2013, 164 : 131 - 138
  • [3] Coupling of heat, water vapor, and liquid water fluxes to compute evaporation in bare soils
    Bittelli, Marco
    Ventura, Francesca
    Campbell, Gaylon S.
    Snyder, Richard L.
    Gallegati, Fabia
    Pisa, Paola Rossi
    [J]. JOURNAL OF HYDROLOGY, 2008, 362 (3-4) : 191 - 205
  • [4] A small multi-needle probe for measuring soil thermal properties, water content and electrical conductivity
    Bristow, KL
    Kluitenberg, GJ
    Goding, CJ
    Fitzgerald, TS
    [J]. COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2001, 31 (03) : 265 - 280
  • [5] Estimating groundwater recharge through unsaturated flow modelling: Sensitivity to boundary conditions and vertical discretization
    Carrera-Hernandez, J. J.
    Smerdon, B. D.
    Mendoza, C. A.
    [J]. JOURNAL OF HYDROLOGY, 2012, 452 : 90 - 101
  • [6] ENHANCEMENT OF THERMAL WATER-VAPOR DIFFUSION IN SOIL
    CASS, A
    CAMPBELL, GS
    JONES, TL
    [J]. SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 1984, 48 (01) : 25 - 32
  • [7] SOIL HEAT AND WATER-FLOW WITH A PARTIAL SURFACE MULCH
    CHUNG, SO
    HORTON, R
    [J]. WATER RESOURCES RESEARCH, 1987, 23 (12) : 2175 - 2186
  • [8] Hot Wire Needle Probe for In-Reactor Thermal Conductivity Measurement
    Daw, Joshua E.
    Rempe, Joy L.
    Knudson, Darrell L.
    [J]. IEEE SENSORS JOURNAL, 2012, 12 (08) : 2554 - 2560
  • [9] De VRIES D. A., 1958, TRANS AMER GEOPHYS UNION, V39, P909
  • [10] de Vries D.A., 1963, PHYS PLANT ENV, P210