Detection of anti-dsDNA antibodies by computer-aided automated immunofluorescence analysis

被引:12
|
作者
Lakos, Gabriella [1 ]
Gonzalez, Marlene [1 ]
Flaherty, David [1 ]
Bentow, Chelsea [1 ]
Ibarra, Claudia [2 ]
Stimson, Deborah [2 ]
Nacario, Lori [2 ]
Hiemann, Rico [3 ]
Dervieux, Thierry [2 ]
机构
[1] Inova Diagnost Inc, San Diego, CA 92182 USA
[2] Exagen Diagnost, Vista, CA USA
[3] Brandenburg Univ Technol Cottbus Senftenberg, Fac Nat Sci, Senftenberg, Germany
关键词
dsDNA; Autoantibodies; Indirect immunofluorescence; Systemic lupus erythematosus; Crithidia luciliae; DOUBLE-STRANDED DNA; CRITHIDIA-LUCILIAE; CLASSIFICATION; ASSAYS; FARR;
D O I
10.1016/j.jim.2016.02.019
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Introduction: NOVA View is a computer aided fluorescence microscope that is used for the automated reading and interpretation of indirect immunofluorescent tests in diagnostic immunology. The objective of the present study was to evaluate the performance of the NOVA View system for the measurement of anti-dsDNA antibodies using the Crithidia luciliae indirect immunofluorescence test (CLIFT) technology. Methods: Analytical performance of NOVA View CLIFF was assessed in repeatability (within run) and reproducibility (between runs and instruments) studies. Two hundred-fifty patient samples (N = 200 consecutive samples and N = 50 samples from systemic lupus erythematosus patients) were tested to evaluate the agreement between results generated with NOVA View CLIFF, and those obtained with manual microscopic reading of the same slides. Positivity rate in SLE was assessed on the 50 SLE samples. Results: The NOVA View system showed high level of repeatability and reproducibility within runs, between runs, and between instruments. Agreement of NOVA View software interpretation and digital image reading results with manual microscopic reading results was 96.0%, and the same positivity rate was obtained on SLE samples by NOVA View digital image reading as that of manual microscopic reading (36.0% vs. 38.0%, respectively). Conclusion: Results generated by NOVA View CLIFF were equivalent to those obtained by manual microscopic reading on a large routine sample set. NOVA View demonstrated consistency within and between runs, and between instruments. Automation of CLIFF provides reliability and is a suitable alternative for routine clinical laboratories. (C) 2016 The Authors. Published by Elsevier B.V.
引用
收藏
页码:17 / 22
页数:6
相关论文
共 50 条
  • [21] Naturally occurring V region connected antibodies inhibit anti-dsDNA antibody reactivity with dsDNA
    Srdic-Rajic, Tatjana
    Jurisic, Vladimir
    Andrejevic, Sladjana
    Bonaci-Nikolic, Branka
    Bowker, Timothy
    Concas, Daniela
    Metlas, Radmila
    IMMUNOBIOLOGY, 2012, 217 (01) : 111 - 117
  • [22] THE CLINICAL-SIGNIFICANCE OF MEASURING DIFFERENT ANTI-DSDNA ANTIBODIES BY USING THE FARR ASSAY, AN ENZYME-IMMUNOASSAY AND A CRITHIDIA-LUCILIAE IMMUNOFLUORESCENCE TEST
    WERLE, E
    BLAZEK, M
    FIEHN, W
    LUPUS, 1992, 1 (06) : 369 - 377
  • [23] The Therapeutic Strategies for SLE by Targeting Anti-dsDNA Antibodies
    Wang, Yaqi
    Xiao, Shengxiang
    Xia, Yumin
    Wang, Huixia
    CLINICAL REVIEWS IN ALLERGY & IMMUNOLOGY, 2022, 63 (02) : 152 - 165
  • [24] Comparison of current methods for anti-dsDNA antibody detection and reshaping diagnostic strategies
    Infantino, Maria
    Palterer, Boaz
    Previtali, Giulia
    Alessio, Maria-Grazia
    Villalta, Danilo
    Carbone, Teresa
    Platzgummer, Stefan
    Paura, Giusi
    Castiglione, Caterina
    Fabris, Martina
    Pesce, Giampaola
    Porcelli, Brunetta
    Terzuoli, Lucia
    Bacarelli, Maria-Romana
    Tampoia, Marilina
    Cinquanta, Luigi
    Brusca, Ignazio
    Buzzolini, Francesca
    Benucci, Maurizio
    Tortora, Matteo
    Tronchin, Lorenzo
    Guarrasi, Valerio
    Soda, Paolo
    Manfredi, Mariangela
    Bizzaro, Nicola
    SCANDINAVIAN JOURNAL OF IMMUNOLOGY, 2022, 96 (06)
  • [25] Clinical significance of ELISA positive and immunofluorescence negative anti-dsDNA antibody
    Kim, Kyeong Hee
    Han, Jin Yeong
    Kim, Jeong Man
    Lee, Sung Won
    Chung, Won Tae
    CLINICA CHIMICA ACTA, 2007, 380 (1-2) : 182 - 185
  • [26] Systemic Lupus Erythematosus with and without Anti-dsDNA Antibodies: Analysis from a Large Monocentric Cohort
    Fabrizio, Conti
    Fulvia, Ceccarelli
    Carlo, Perricone
    Laura, Massaro
    Elisa, Marocchi
    Francesca, Miranda
    Romana, Spinelli Francesca
    Simona, Truglia
    Cristiano, Alessandri
    Guido, Valesini
    MEDIATORS OF INFLAMMATION, 2015, 2015
  • [27] Automated antinuclear immunofluorescence antibody screening: A comparative study of six computer-aided diagnostic systems
    Bizzaro, Nicola
    Antico, Antonio
    Platzgummer, Stefan
    Tonutti, Elio
    Bassetti, Danila
    Pesente, Fiorenza
    Tozzoli, Renato
    Tampoia, Marilina
    Villalta, Danilo
    AUTOIMMUNITY REVIEWS, 2014, 13 (03) : 292 - 298
  • [28] Detection of Antinuclear Antibodies (ANA), Antibodies to Double Stranded DNA (Anti-Dsdna) and Antibodies to Extractable Nuclear Antigens (Anti-ENA) in Greek Patients
    Stamouli, Marilena
    Skliris, Anastasios
    Reppa, Droseri
    Maganaki, Evangelia
    Totos, Grigorios
    CLINICAL LABORATORY, 2013, 59 (3-4) : 283 - 291
  • [29] Anti-dsDNA antibodies in systemic lupus erythematosus: A combination of two quantitative methods and the ANA pattern is the most efficient strategy of detection
    Almeida Gonzalez, Delia
    Roces Varela, Alfredo
    Marcelino Rodriguez, Itahisa
    Gonzalez Vera, Alexander
    Delgado Sanchez, Monica
    Aznar Esquivel, Antonio
    Casanas Rodriguez, Carlos
    Cabrera de Leon, Antonio
    JOURNAL OF IMMUNOLOGICAL METHODS, 2015, 427 : 30 - 35
  • [30] Clinical evaluation of a new automated anti-dsDNA fluorescent immunoassay
    Hernando, M
    González, C
    Sánchez, A
    Guevara, P
    Navajo, JA
    Papisch, W
    González-Buitrago, JM
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2002, 40 (10) : 1056 - 1060