FAST SPECTROMETRIC METHOD FOR MERCURY(II) DETERMINATION BASED ON GLUCOSE-OXIDASE INHIBITION

被引:6
|
作者
Ciucu, A. [1 ]
机构
[1] Univ Bucharest, Dept Analyt Chem, Bucharest 76234, Romania
关键词
Glucose-oxidase; Inhibition; Kinetic; Mercury; Spectrometric; ENZYME-INHIBITION; HEAVY-METALS; INJECTION-ANALYSIS; BIOSENSORS; SENSOR; PESTICIDES; ASSAYS; IONS; WATER; FIA;
D O I
10.1080/00032710903518781
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fast spectrometric kinetic method for mercury(II) ions determination based on their property to inhibit glucose-oxidase activity is presented. The measurement of enzyme activity was based on enzymatic reduction of benzoquinone to hydroquinone and on the measurements of the initial rate of hydroquinone absorbance increase at 290 nm. A calibration curve for Hg(II) concentrations was obtained in the 0.05-1.0 mu g/mL range, with a detection limit of 0.015 mu g/mL and a relative standard deviation RSD <= 2.7%. The analysis time was 2 min. Determination of mercury in a real sample was in good agreement with the declared mercury concentration.
引用
收藏
页码:1377 / 1386
页数:10
相关论文
共 50 条
  • [41] Selective Spectrophotometric Method for the Determination of Mercury(II) in Water Samples
    Lilhare, Surbhi
    Mathew, Sunitha B.
    Singh, Ajaya K.
    Carabineiro, Sonia A. C.
    ANALYTICAL CHEMISTRY LETTERS, 2020, 10 (05) : 654 - 666
  • [42] Polypyrrole-based Enzyme Electrode with Immobilized Glucose Oxidase for Electrochemical Determination of Glucose
    Jugovic, Branimir
    Grgur, Branimir
    Antov, Mirjana
    Knezevic-Jugovic, Zorica
    Stevanovic, Jasmina
    Gvozdenovic, Milica
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (02): : 1152 - 1161
  • [43] ENZYME LABELING IN STEROID ENZYME IMMUNOASSAYS - THE PARA-NITROPHENYL ESTER METHOD FOR ALKALINE-PHOSPHATASE AND GLUCOSE-OXIDASE LABELINGS
    HOSODA, H
    FUKUDA, K
    GOTO, J
    CHEMICAL & PHARMACEUTICAL BULLETIN, 1992, 40 (05) : 1325 - 1326
  • [44] Determination of protamine and heparin based on their effects on a glucose oxidase enzymatic reaction
    Uematsu, Kohei
    Ueno, Takaaki
    Katano, Hajime
    ANALYTICAL SCIENCES, 2023, 39 (9) : 1561 - 1566
  • [45] Simple, fast, and ultrasensitive method for textile dye determination based on luminol electrochemiluminescence (ECL) inhibition
    Carolina V. Uliana
    Hideko Yamanaka
    Journal of Solid State Electrochemistry, 2020, 24 : 1927 - 1933
  • [46] Determination of protamine and heparin based on their effects on a glucose oxidase enzymatic reaction
    Kohei Uematsu
    Takaaki Ueno
    Hajime Katano
    Analytical Sciences, 2023, 39 : 1561 - 1566
  • [47] Simple, fast, and ultrasensitive method for textile dye determination based on luminol electrochemiluminescence (ECL) inhibition
    Uliana, Carolina V.
    Yamanaka, Hideko
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2020, 24 (08) : 1927 - 1933
  • [48] Sensitive determination of urinary mercury(II) by a bioluminescent transgenic bacteria-based biosensor
    Roda, A
    Pasini, P
    Mirasoli, N
    Guardigli, M
    Russo, C
    Musiani, M
    Baraldini, M
    ANALYTICAL LETTERS, 2001, 34 (01) : 29 - 41
  • [49] A Simple Image Analysis Method for Determination of Glucose by using Glucose Oxidase CdTe/TGA Quantum Dots
    Tashkhourian, J.
    Akhond, M.
    Hooshmand, S.
    Khosousi, T.
    Hemmateenejad, B.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2014, 1 (02): : 117 - 127
  • [50] Inhibition of rhodamine B-ferricyanide chemiluminescence by Au nanoparticles toward the sensitive determination of mercury (II) ions
    Vahid, Behrouz
    Hassanzadeh, Javad
    Abolhasani, Jafar
    Khodakarami, Behzad
    MICROCHEMICAL JOURNAL, 2016, 126 : 326 - 331