FAST SPECTROMETRIC METHOD FOR MERCURY(II) DETERMINATION BASED ON GLUCOSE-OXIDASE INHIBITION

被引:6
|
作者
Ciucu, A. [1 ]
机构
[1] Univ Bucharest, Dept Analyt Chem, Bucharest 76234, Romania
关键词
Glucose-oxidase; Inhibition; Kinetic; Mercury; Spectrometric; ENZYME-INHIBITION; HEAVY-METALS; INJECTION-ANALYSIS; BIOSENSORS; SENSOR; PESTICIDES; ASSAYS; IONS; WATER; FIA;
D O I
10.1080/00032710903518781
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fast spectrometric kinetic method for mercury(II) ions determination based on their property to inhibit glucose-oxidase activity is presented. The measurement of enzyme activity was based on enzymatic reduction of benzoquinone to hydroquinone and on the measurements of the initial rate of hydroquinone absorbance increase at 290 nm. A calibration curve for Hg(II) concentrations was obtained in the 0.05-1.0 mu g/mL range, with a detection limit of 0.015 mu g/mL and a relative standard deviation RSD <= 2.7%. The analysis time was 2 min. Determination of mercury in a real sample was in good agreement with the declared mercury concentration.
引用
收藏
页码:1377 / 1386
页数:10
相关论文
共 50 条
  • [31] Glucose concentration determination based on silica sol-gel encapsulated glucose oxidase optical biosensor arrays
    Chang, Gang
    Tatsu, Yoshiro
    Goto, Tatsushi
    Imaishi, Hiromasa
    Morigaki, Kenichi
    TALANTA, 2010, 83 (01) : 61 - 65
  • [32] Determination of glucose oxidase activity of flour additive by fluorescence quenching method
    Dong, Na
    Zhang, Aiju
    Dai, Xingde
    Zhang, Xiaolin
    He, Fangzhen
    CHEMICAL PAPERS, 2025, 79 (01) : 599 - 605
  • [33] A Novel Biosensor Based on Glucose Oxidase for Activity Determination of α - Amylase
    Altug, Cagri
    Mengulluoglu, Umut
    Kurt, Elif
    Kaya, Secil
    Dinckaya, Erhan
    ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2011, 39 (05): : 298 - 303
  • [34] GLUCOSE SENSOR-BASED ON CARBON-PASTE ELECTRODE INCORPORATING POLY(ETHYLENE GLYCOL)-MODIFIED GLUCOSE-OXIDASE AND VARIOUS MEDIATORS
    SABY, C
    MIZUTANI, F
    YABUKI, S
    ANALYTICA CHIMICA ACTA, 1995, 304 (01) : 33 - 39
  • [35] Colorimetric determination of mercury(II) via the inhibition by ssDNA of the oxidase-like activity of a mixed valence state cerium-based metal-organic framework
    Wang, Caihong
    Tang, Gonge
    Tan, Hongliang
    MICROCHIMICA ACTA, 2018, 185 (10)
  • [36] BIOSENSING OF RAPESEED GLUCOSINOLATES USING AMPEROMETRIC ENZYME ELECTRODES BASED ON MEMBRANE-BOUND GLUCOSE-OXIDASE OR TYROSINASE
    STANCIK, L
    MACHOLAN, L
    PLUHACEK, I
    SCHELLER, F
    ELECTROANALYSIS, 1995, 7 (08) : 726 - 730
  • [37] A Test Method for the Determination of Mercury(I, II) on a Polymer Surface
    R. F. Gur'eva
    S. B. Savvin
    Journal of Analytical Chemistry, 2003, 58 : 990 - 994
  • [38] A test method for the determination of mercury(I, II) on a polymer surface
    Gur'eva, RF
    Savvin, SB
    JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 58 (10) : 990 - 994
  • [39] ONE-STEP FABRICATION OF GLUCOSE SENSORS BASED ON ENTRAPMENT OF GLUCOSE-OXIDASE WITHIN POLY(ESTER SULFONIC-ACID) COATINGS
    WANG, J
    LEECH, D
    OZSOZ, M
    MARTINEZ, S
    SMYTH, MR
    ANALYTICA CHIMICA ACTA, 1991, 245 (02) : 139 - 143
  • [40] A Fast and Direct Amperometric Determination of Hg2+ by a Bienzyme Electrode Based on the Competitive Activities of Glucose Oxidase and Laccase
    Cosnier, Serge
    Mousty, Christine
    Guelorget, Amandine
    Lopez, Marta Sanchez-Paniagua
    Shan, Dan
    ELECTROANALYSIS, 2011, 23 (08) : 1776 - 1779