FAST SPECTROMETRIC METHOD FOR MERCURY(II) DETERMINATION BASED ON GLUCOSE-OXIDASE INHIBITION

被引:6
|
作者
Ciucu, A. [1 ]
机构
[1] Univ Bucharest, Dept Analyt Chem, Bucharest 76234, Romania
关键词
Glucose-oxidase; Inhibition; Kinetic; Mercury; Spectrometric; ENZYME-INHIBITION; HEAVY-METALS; INJECTION-ANALYSIS; BIOSENSORS; SENSOR; PESTICIDES; ASSAYS; IONS; WATER; FIA;
D O I
10.1080/00032710903518781
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fast spectrometric kinetic method for mercury(II) ions determination based on their property to inhibit glucose-oxidase activity is presented. The measurement of enzyme activity was based on enzymatic reduction of benzoquinone to hydroquinone and on the measurements of the initial rate of hydroquinone absorbance increase at 290 nm. A calibration curve for Hg(II) concentrations was obtained in the 0.05-1.0 mu g/mL range, with a detection limit of 0.015 mu g/mL and a relative standard deviation RSD <= 2.7%. The analysis time was 2 min. Determination of mercury in a real sample was in good agreement with the declared mercury concentration.
引用
收藏
页码:1377 / 1386
页数:10
相关论文
共 50 条
  • [21] DEVELOPMENT AND EVALUATION OF GLUCOSE MICROSENSORS BASED ON ELECTROCHEMICAL CODEPOSITION OF RUTHENIUM AND GLUCOSE-OXIDASE ONTO CARBON-FIBER MICROELECTRODES
    SAKSLUND, H
    WANG, J
    LU, F
    HAMMERICH, O
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 397 (1-2): : 149 - 155
  • [22] ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .5. MICROELECTRODES FOR THE DETECTION OF GLUCOSE BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN A POLY(PHENOL) FILM
    BARTLETT, PN
    CARUANA, DJ
    ANALYST, 1992, 117 (08) : 1287 - 1292
  • [23] Catalase based hydrogen peroxide biosensor for mercury determination by inhibition measurements
    Elsebai, Basant
    Ghica, Mariana Emilia
    Abbas, Mohammed Nooredeen
    Brett, Christopher M. A.
    JOURNAL OF HAZARDOUS MATERIALS, 2017, 340 : 344 - 350
  • [24] Thermally stable improved first-generation glucose biosensors based on Nafion/glucose-oxidase modified heated electrodes
    Tseng, Ta-Feng
    Yang, Yang-Li
    Chuang, Min-Chieh
    Lou, Shyh-Liang
    Galik, Michal
    Flechsig, Gerd-Uwe
    Wang, Joseph
    ELECTROCHEMISTRY COMMUNICATIONS, 2009, 11 (09) : 1819 - 1822
  • [25] Construction of a Carbon Paste Electrode Based on Novel Thiolated Ligand Capped Gold Nanoparticles for Determination of Trace Amounts of Mercury(II)
    Fayazi, Raziyeh
    Ghanei-Motlagh, Masoud
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2019, 6 (01): : 1 - 12
  • [26] Fibre optic biosensor for the determination of D-glucose based on absorption changes of immobilized glucose oxidase
    Chudobova, I
    Vrbova, E
    Kodicek, M
    Janovcova, J
    Kas, J
    ANALYTICA CHIMICA ACTA, 1996, 319 (1-2) : 103 - 110
  • [27] AMPEROMETRIC ENZYME ELECTRODE FOR SUCROSE DETERMINATION PREPARED FROM GLUCOSE-OXIDASE AND INVERTASE CO-IMMOBILIZED IN POLY(VINYLFERROCENIUM)
    GULCE, H
    CELEBI, SS
    OZYORUK, H
    YILDIZ, A
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 397 (1-2): : 217 - 223
  • [28] Determination of nicotine based on the inhibition of nicotine to the choline oxidase
    Yang, MH
    Yang, YH
    Shen, GL
    Yu, RQ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (04) : 479 - 482
  • [29] A novel method for glucose determination based on electrochemical impedance spectroscopy using glucose oxidase self-assembled biosensor
    Shervedani, Reza Karimi
    Mehrjardi, Abdolhamid Hatefi
    Zamiri, Najmehsadat
    BIOELECTROCHEMISTRY, 2006, 69 (02) : 201 - 208
  • [30] FLOW-INJECTION ANALYSIS OF GLUCOSE AT AN AMPEROMETRIC GLUCOSE SENSOR-BASED ON ELECTROCHEMICAL CODEPOSITION OF PALLADIUM AND GLUCOSE-OXIDASE ON A GLASSY-CARBON ELECTRODE
    CHI, QJ
    DONG, SJ
    ANALYTICA CHIMICA ACTA, 1993, 278 (01) : 17 - 23