Finite-time convergence robust control of battery energy storage system to mitigate wind power fluctuations

被引:23
作者
Deng, Zicong [1 ]
Xu, Yinliang [1 ]
Gu, Wei [2 ]
Fei, Zhongyang [3 ]
机构
[1] Sun Yat Sen Univ, Sch Elect & Informat Technol, SYSUCMU Joint Inst Engn, Guangzhou 510275, Guangdong, Peoples R China
[2] Southeast Univ, Sch Elect Engn, Nanjing 210096, Jiangsu, Peoples R China
[3] Harbin Inst Technol, Res Inst Intelligent Control & Syst, Harbin 150001, Peoples R China
基金
中国国家自然科学基金;
关键词
Finite-time convergence; Robust control; Energy storage system; State of charge; Uncertainty; SLIDING-MODE CONTROL; CONTROL SCHEME; INTEGRATION; COORDINATION;
D O I
10.1016/j.ijepes.2017.03.012
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Wind energy is envisioned to be one of the most promising clean and renewable energy to drive our future society. Due to its intermittency nature, wind power may change rapidly and frequently. Wind power fluctuations pose great challenges on power quality, reliability and raise many other issues like frequency and voltage regulation. This paper proposes a finite-time convergence robust control algorithm of battery energy storage system (BESS) to mitigate the wind power fluctuations. The major advantages of the proposed algorithm include, being insensitive to uncertainty and disturbance, enabling adjustable convergence time to accommodate different operating conditions and maintaining the state of charge (SOC) within a proper range for regulation capability reserve. Finite-time convergence of the proposed algorithm is derived through rigorous analysis. Simulation results demonstrate the effectiveness of the proposed algorithm. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:144 / 154
页数:11
相关论文
共 39 条
[1]   Supercapacitor energy storage for wind energy applications [J].
Abbey, Chad ;
Joos, Geza .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2007, 43 (03) :769-776
[2]   A Knowledge-Based Approach for Control of Two-Level Energy Storage for Wind Energy Systems [J].
Abbey, Chad ;
Strunz, Kai ;
Joos, Geza .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2009, 24 (02) :539-547
[3]   A power control strategy for flywheel doubly-fed induction machine storage system using artificial neural network [J].
Abdel-Khalik, A. ;
Elserougi, A. ;
Massoud, A. ;
Ahmed, S. .
ELECTRIC POWER SYSTEMS RESEARCH, 2013, 96 :267-276
[4]   Market-Oriented Energy Management of a Hybrid Wind-Battery Energy Storage System Via Model Predictive Control With Constraint Optimizer [J].
Abdeltawab, Hussein Hassan ;
Mohamed, Yasser Abdel-Rady I. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (11) :6658-6670
[5]   Development of an efficient utility interactive combined wind/photovoltaic/fuel cell power system with MPPT and DC bus voltage regulation [J].
Ahmed, Nabil A. ;
Al-Othman, A. K. ;
AlRashidi, M. R. .
ELECTRIC POWER SYSTEMS RESEARCH, 2011, 81 (05) :1096-1106
[6]   Impact of charging efficiency variations on the effectiveness of variable-rate-based charging strategies for electric vehicles [J].
Amoroso, Francesco A. ;
Cappuccino, Gregorio .
JOURNAL OF POWER SOURCES, 2011, 196 (22) :9574-9578
[7]   Causes of the 2003 major grid blackouts in north America and Europe, and recommended means to improve System Dynamic Performance [J].
Andersson, G ;
Donalek, P ;
Farmer, R ;
Hatziargyriou, N ;
Kamwa, I ;
Kundur, P ;
Martins, N ;
Paserba, J ;
Pourbeik, P ;
Sanchez-Gasca, J ;
Schulz, R ;
Stankovic, A ;
Taylor, C ;
Vittal, V .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2005, 20 (04) :1922-1928
[8]   Power smoothing in wind generation systems using a sensorless vector controlled induction machine driving a flywheel [J].
Cárdenas, R ;
Peña, R ;
Asher, G ;
Clare, J .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2004, 19 (01) :206-216
[9]   New dynamical models of lead-acid batteries [J].
Ceraolo, M .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2000, 15 (04) :1184-1190
[10]   Enhancing Frequency Response Control by DFIGs in the High Wind Penetrated Power Systems [J].
Chang-Chien, Lee-Ren ;
Lin, Wei-Ting ;
Yin, Yao-Ching .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2011, 26 (02) :710-718