Silent and Apparent Cerebral Ischemia After Percutaneous Transfemoral Aortic Valve Implantation A Diffusion-Weighted Magnetic Resonance Imaging Study

被引:424
|
作者
Kahlert, Philipp [1 ]
Knipp, Stephan C. [2 ]
Schlamann, Marc [3 ]
Thielmann, Matthias [2 ]
Al-Rashid, Fadi
Weber, Marcel
Johansson, Uw [4 ]
Wendt, Daniel [2 ]
Jakob, Heinz G. [2 ]
Forsting, Michael [3 ]
Sack, Stefan
Erbel, Raimund
Eggebrecht, Holger
机构
[1] Univ Duisburg Essen, Dept Cardiol, W German Heart Ctr Essen, D-45122 Essen, Germany
[2] W German Heart Ctr Essen, Dept Thorac & Cardiovasc Surg, Essen, Germany
[3] Univ Duisburg Essen, Univ Hosp Essen, Inst Diagnost & Intervent Radiol & Neuroradiol, D-45122 Essen, Germany
[4] Univ Duisburg Essen, Univ Hosp Essen, Dept Neurol, D-45122 Essen, Germany
关键词
cerebral ischemia; magnetic resonance imaging; stenosis; heart valve prosthesis implantation; bioprosthesis; valves; HEALTH STROKE SCALE; CARDIAC-CATHETERIZATION; ATHEROSCLEROTIC DISEASE; HEART-VALVE; STENOSIS; RISK; REPLACEMENT; PROSTHESIS; MORTALITY; DEBRIS;
D O I
10.1161/CIRCULATIONAHA.109.855866
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The risk of stroke after transfemoral aortic valve implantation (TAVI) due to dislodgement and subsequent embolization of debris from aortic arch atheroma or from the calcified valve itself ranges between 2% and 10%. The rate of clinically silent cerebral ischemia is unknown but may be even higher. Methods and Results-Thirty-two patients who underwent TAVI with the use of a balloon-expandable (n=22) or self-expandable (n=10) stent valve prosthesis were included in this descriptive study and compared with a historical control group of 21 patients undergoing open surgical aortic valve replacement. Periprocedural apparent and silent cerebral ischemia was assessed by neurological testing and serial cerebral diffusion-weighted magnetic resonance imaging at baseline, at 3.4 (2.5 to 4.4) days after the procedure, and at 3 months. TAVI was successful in all patients. After the procedure, new foci of restricted diffusion on cerebral diffusion-weighted magnetic resonance imaging were found in 27 of 32 TAVI patients (84%) and were more frequent than after open surgery (10 of 21 patients [48%]; P=0.011). These lesions were usually multiple (1 to 19 per patient) and dispersed in both hemispheres in a pattern suggesting cerebral embolization. Volumes of these lesions were significantly smaller after TAVI than after surgery (77 [59 to 94] versus 224 [111 to 338] mm(3); P<0.001). There were neither measurable impairments of neurocognitive function nor apparent neurological events during the in-hospital period among TAVI patients, but there was 1 stroke (5%) in the surgical patient group. On 3-month follow-up diffusion-weighted magnetic resonance imaging, there were no new foci of restricted diffusion, and there was no residual signal change associated with the majority (80%) of the foci detected in the periprocedural period. Conclusions-Clinically silent new foci of restricted diffusion on cerebral magnetic resonance imaging were detected in almost all patients (84%) undergoing TAVI. Although typically multiple, these foci were not associated with apparent neurological events or measurable deterioration of neurocognitive function during 3-month follow-up. Further work needs to be directed to determine the clinical significance of these findings in a larger patient population. (Circulation. 2010; 121:870-878.)
引用
收藏
页码:870 / 878
页数:9
相关论文
共 50 条
  • [1] Risk and Fate of Cerebral Embolism After Transfemoral Aortic Valve Implantation A Prospective Pilot Study With Diffusion-Weighted Magnetic Resonance Imaging
    Ghanem, Alexander
    Mueller, Andreas
    Naehle, Claas P.
    Kocurek, Justine
    Werner, Nikos
    Hammerstingl, Christoph
    Schild, Hans H.
    Schwab, Joerg O.
    Mellert, Fritz
    Fimmers, Rolf
    Nickenig, Georg
    Thomas, Daniel
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (14) : 1427 - 1432
  • [2] Impact of Cerebral Embolism related to Transfemoral Aortic Valve Implantation on Neurocognitive Function - Prospective Study with Diffusion-Weighted Magnetic Resonance Imaging
    Ghanem, Alexander
    Mueller, Andreas
    Becker, Benjamin V.
    Sinning, Jan M.
    Werner, Nikos
    Hammerstingl, Christoph
    Schwab, Joerg O.
    Naehle, Claas P.
    Popp, Julius
    Wagner, Michael
    Schild, Hans H.
    Thomas, Daniel
    Nickenig, Georg
    CIRCULATION, 2010, 122 (21)
  • [3] Vascular Access Site Complications after Percutaneous Transfemoral Aortic Valve Implantation
    Kahlert, Philipp
    Al-Rashid, Fadi
    Weber, Marcel
    Wendt, Daniel
    Heine, Torsten
    Kottenberg, Eva
    Thielmann, Matthias
    Kuehl, Hilmar
    Peters, Juergen
    Jakob, Heinz G.
    Sack, Stefan
    Erbel, Raimund
    Eggebrecht, Holger
    HERZ, 2009, 34 (05) : 398 - 408
  • [4] Embolic Cerebral Insults After Transapical Aortic Valve Implantation Detected by Magnetic Resonance Imaging
    Arnold, Martin
    Schulz-Heise, Susanne
    Achenbach, Stephan
    Ott, Sabine
    Doerfler, Arnd
    Ropers, Dieter
    Feyrer, Richard
    Einhaus, Friedrich
    Loders, Sabrina
    Mahmoud, Faidi
    Roerick, Olaf
    Daniel, Werner G.
    Weyand, Michael
    Ensminger, Stephan M.
    Ludwig, Josef
    JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (11) : 1126 - 1132
  • [5] Magnetic resonance imaging evaluation of cerebral embolization during percutaneous aortic valve implantation: comparison of transfemoral and trans-apical approaches using Edwards Sapiens valve
    Astarci, Parla
    Glineur, David
    Kefer, Joelle
    D'Hoore, William
    Renkin, Jean
    Vanoverschelde, Jean-Louis
    El Khoury, Gebrine
    Grandin, Cecile
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 40 (02) : 475 - 479
  • [6] Cerebral Embolic Infarcts Following Transcatheter Aortic Valve Implantation: A Diffusion-Weighted Magnetic Resonance Imaging Study and the Assessment of Subsequent Health Status.
    Fairbairn, Timothy A.
    Mather, Adam N.
    Bijsterveld, Petra
    Currie, Stuart
    Goddard, Anthony
    Blackman, Dan
    Plein, Sven
    Greenwood, John
    CIRCULATION, 2010, 122 (21)
  • [7] Delayed Coronary Ischemia after Transfemoral Aortic Valve Implantation
    Jategaonkar, Smita R.
    Dimitriadis, Zisis
    Hakim-Meibodi, Kavous
    Gummert, Jan
    Horstkotte, Dieter
    Scholtz, Werner
    JOURNAL OF HEART VALVE DISEASE, 2013, 22 (06) : 762 - 766
  • [8] Impact of Asymptomatic Cerebral Lesions in Diffusion-Weighted Magnetic Resonance Imaging After Carotid Artery Stenting
    Bijuklic, Klaudija
    Wandler, Andreas
    Tuebler, Thilo
    Schofer, Joachim
    JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (04) : 394 - 398
  • [9] Anemia and risk of periprocedural cerebral injury detected by diffusion-weighted magnetic resonance imaging in patients undergoing transcatheter aortic valve replacement
    Ng, Stella
    Zhu, Qi-feng
    Jiang, Ju-bo
    Liu, Chun-hui
    Fan, Jia-qi
    Xu, Ye-ming
    Liu, Xian-bao
    Wang, Jian-an
    WORLD JOURNAL OF EMERGENCY MEDICINE, 2022, 13 (01) : 32 - 39
  • [10] Diffusion-weighted magnetic resonance imaging for demonstration of cerebral infarcts
    Bartylla, K
    Hagen, T
    Globel, H
    Jost, V
    Schneider, G
    RADIOLOGE, 1997, 37 (11): : 859 - 864