First comparison of a new dynamic navigation system and surgical guides for implantology: an in vitro study

被引:0
|
作者
Dure, Michael [1 ]
Berlinghoff, Frank [1 ]
Kollmuss, Maximilian [1 ]
Hickel, Reinhard [1 ]
Huth, Karin Christine [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, Dept Conservat Dent & Periodontol, Univ Hosp, Goethestr 70, D-80336 Munich, Germany
关键词
dynamic navigation; dental implantology; surgical guide; implant planning; ACCURACY; PLACEMENT; SURGERY;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: The transfer of 3D implant position planning to the clinical site is challenging. The aim of this study was to compare in vitro this transfer accuracy by using dynamic real-time navigation or static surgical guides. Materials and methods: Deviations between planned and actual pilot drill positions were calculated (Denacam and NobelGuide; each n = 90), matching pre- and postoperative CBCT images: entry point, angle, tip (each 3D); depth, mesiodistal/bucco-oral entry points, and angles (each 1D). The influence of the maxilla and mandible, implant region (anterior/posterior), and marker position (ipsilateral/contralateral, Denacam only) was investigated (Mann-Whitney U test). Results: No significant differences occurred regarding entry point (3D), mesiodistal/bucco-oral entry points (1D) or mesiodistal angle (1D) (P > 0.05). The angular and tip deviations (3D) were significantly smaller using Denacam (2.16 +/- 0.59 degrees, 0.80 +/- 0.55 mm; NobelGuide 2.54 +/- 1.19 degrees, 1.09 +/- 0.56 mm; P = 0.024, P < 0.0001). The deviations in depth and bucco- oral angle (1D) were significantly smaller using NobelGuide (1.05 +/- 0.50 mm, 1.02 +/- 1.16 degrees; Denacam 1.50 +/- 0.64 mm, 1.51 +/- 0.82 degrees; P < 0.0001). Significantly smaller deviations occurred within the mandible (Denacam, 5/8 parameters). Region and marker position showed no influence. No distinct influences were found with the use of NobelGuide. Conclusion: Denacam might possibly be a promising alternative to static surgical guides.
引用
收藏
页码:9 / 17
页数:9
相关论文
共 50 条
  • [1] Study About the Precision of Surgical Guides Used in Implantology
    Mihai, Ionut Daniel
    Mihai, Roxana
    Vartolomei, Claudiu
    Comaneanu, Raluca Monica
    Coman, Stefania
    Ghergic, Doina Lucia
    REVISTA DE CHIMIE, 2018, 69 (03): : 660 - 664
  • [2] Comparison of robotic system and dynamic navigation for zygomatic implant placement: An in vitro study
    Guo, Houzuo
    Jiang, Xi
    Lin, Ye
    JOURNAL OF DENTISTRY, 2024, 150
  • [3] Dynamic Navigation in Dental Implantology: The Influence of Surgical Experience on Implant Placement Accuracy and Operating Time. An in Vitro Study
    Pellegrino, Gerardo
    Bellini, Pierantonio
    Cavallini, Pier Francesco
    Ferri, Agnese
    Zacchino, Andrea
    Taraschi, Valerio
    Marchetti, Claudio
    Consolo, Ugo
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (06)
  • [4] Computer-assisted surgical navigation system in dental implantology
    Feng, Eric
    Gu, Lixu
    Huang, Yuanliang
    Chang, Shixin
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2006, 1 : 417 - 419
  • [5] A Novel Irrigation System to Reduce Heat Generation during Guided Implantology: An In Vitro Study
    Parvizi, Somayeh
    Cameron, Andrew
    Tadakamadla, Santosh
    Figueredo, Carlos Marcelo S.
    Reher, Peter
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (12)
  • [6] Computer-assisted preoperative planning and surgical navigation system in dental implantology
    Zheng, Guangchao.
    Gu, Lixu.
    Li, Xiaobo.
    Zhang, Jingsi.
    2007 6TH INTERNATIONAL SPECIAL TOPIC CONFERENCE ON INFORMATION TECHNOLOGY APPLICATIONS IN BIOMEDICINE, 2007, : 73 - 76
  • [7] Comparison the accuracy of a novel implant robot surgery and dynamic navigation system in dental implant surgery: an in vitro pilot study
    Chen, Jianping
    Bai, Xiaolei
    Ding, Yude
    Shen, Liheng
    Sun, Xin
    Cao, Ruijue
    Yang, Fan
    Wang, Linhong
    BMC ORAL HEALTH, 2023, 23 (01)
  • [8] Proposal and Validation of a New Nonradiological Method for Postoperative Three-Dimensional Implant Position Analysis Based on the Dynamic Navigation System: An In Vitro Study
    Ma, Feifei
    Liu, Mingyue
    Liu, Xiaoqiang
    Wei, Tai
    Liu, Lilan
    Sun, Feng
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (02):
  • [9] In Vitro Comparison of Surgical Implant Placement Accuracy Using Guides Fabricated by Three Different Additive Technologies
    Anunmana, Chuchai
    Ueawitthayasuporn, Chananchida
    Kiattavorncharoen, Sirichai
    Thanasrisuebwong, Prakan
    APPLIED SCIENCES-BASEL, 2020, 10 (21): : 1 - 11
  • [10] Accuracy and Self-Confidence Level of Freehand Drilling and Dynamic Navigation System of Dental Implants: An In Vitro Study
    Mampilly, Mathew
    Kuruvilla, Leelamma
    Niyazi, Adham Abdulmajeed Tash
    Shyam, Arun
    Thomas, Pallavi Ammu
    Ali, Anzil S.
    Pullishery, Fawaz
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (11)