Coronary MR angiography: Current status

被引:7
作者
Danias, PG
Manning, WJ
机构
[1] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Charles A Dana Res Inst, Boston, MA 02115 USA
[3] Harvard Univ, Sch Med, Dept Med, Cardiovasc Div,Harvard Thorndike Lab, Boston, MA USA
关键词
magnetic resonance angiography; coronary artery imaging;
D O I
10.1007/s000590050035
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Since first described in the early 1990s, coronary magnetic resonance angiography (MRA) has evolved as a promising noninvasive modality for imaging of the coronary arteries and evaluation of coronary artery disease. Despite technical limitations, coronary MRA has established value for imaging of anomalous coronary arteries and assessment of bypass graft patency. Current research focuses on the development of optimal respiratory compensation strategies, improved spatial and temporal resolution and faster acquisition of image data. The accurate detection of stenoses and assessment of the severity of coronary atherosclerosis is presently being evaluated with large multicenter studies. With further technique enhancements and more clinical experience, coronary MRA is likely to become the dominant noninvasive modality in clinical cardiology.
引用
收藏
页码:431 / 439
页数:9
相关论文
共 73 条
[1]  
*AM HEART ASS, 1996, STAT FACTS
[2]   NONINVASIVE DETERMINATION OF CORONARY-ARTERY BYPASS GRAFT PATENCY BY CINE MAGNETIC-RESONANCE IMAGING [J].
AURIGEMMA, GP ;
REICHEK, N ;
AXEL, L ;
SCHIEBLER, M ;
HARRIS, C ;
KRESSEL, HY .
CIRCULATION, 1989, 80 (06) :1595-1602
[3]   Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA [J].
Botnar, RM ;
Stuber, M ;
Danias, PG ;
Kissinger, KV ;
Manning, WJ .
CIRCULATION, 1999, 99 (24) :3139-3148
[4]   CORONARY ANGIOGRAPHY WITH MAGNETIZATION-PREPARED T-2 CONTRAST [J].
BRITTAIN, JH ;
HU, BS ;
WRIGHT, GA ;
MEYER, CH ;
MACOVSKI, A ;
NISHIMURA, DG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :689-696
[5]   MR IMAGING OF CORONARY-ARTERY FLOW IN ISOLATED AND INVIVO HEARTS [J].
BURSTEIN, D .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (03) :337-346
[6]   NMR ANGIOGRAPHY OF CORONARY VESSELS WITH 2-D PLANAR IMAGE SCANNING [J].
CHO, ZH ;
MUN, CW ;
FRIEDENBERG, RM .
MAGNETIC RESONANCE IN MEDICINE, 1991, 20 (01) :134-143
[7]  
Danias PG, 1999, J MAGN RESON IMAGING, V10, P713, DOI 10.1002/(SICI)1522-2586(199911)10:5<713::AID-JMRI15>3.0.CO
[8]  
2-I
[9]   Navigator assessment of breath-hold duration: Impact of supplemental oxygen and hyperventilation [J].
Danias, PG ;
Stuber, M ;
Botnar, RM ;
Kissinger, KV ;
Chuang, ML ;
Manning, WJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (02) :395-397
[10]   Prospective navigator correction of image position for coronary MR angiography [J].
Danias, PG ;
McConnell, MV ;
Khasgiwala, VC ;
Chuang, ML ;
Edelman, RR ;
Manning, WJ .
RADIOLOGY, 1997, 203 (03) :733-736