Non-Contrast-Enhanced Four-Dimensional (4D) Intracranial MR Angiography: A Feasibility Study

被引:49
作者
Bi, Xiaoming [1 ]
Weale, Peter [1 ]
Schmitt, Peter [2 ]
Zuehlsdorff, Sven [1 ]
Jerecic, Renate [1 ]
机构
[1] Siemens Med Solut USA Inc, Chicago, IL USA
[2] Siemens AG Healthcare, Erlangen, Germany
关键词
magnetic resonance angiography; non-contrast-enhanced; time-resolved; intracranial arteries; hemodynamics; flow visualization; SUBSECOND-TEMPORAL-RESOLUTION; ARTERIOVENOUS-MALFORMATIONS; INVERSION; DSA;
D O I
10.1002/mrm.22220
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
T-1-shortening contrast agents have been widely used in time-resolved magnetic resonance angiography. To match imaging data acquisition with the short time period of the first pass of contrast agent, temporal resolution and/or spatial resolution have to be compromised in many cases. In this study, a novel non-contrast-enhanced technique was developed for time-resolved magnetic resonance angiography. Alternating magnetization preparation was applied in two consecutive acquisitions of each measurement to eliminate the need for contrast media. Without the constraint of contrast media kinetics, temporal resolution is drastically improved from the order of a second as in conventional contrast-enhanced approach to tens of milliseconds (50.9 msec) in this study, without compromising spatial resolution. Initial results from volunteer studies demonstrate the feasibility of this method to depict anatomic structure and dynamic filling of main vessels in the head. Magn Reson Med 63:835-841, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:835 / 841
页数:7
相关论文
共 21 条
[11]   CAROTID-CNS MR FLOW IMAGING [J].
MASARYK, TJ ;
LAUB, GA ;
MODIC, MT ;
ROSS, JS ;
HAACKE, EM .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) :308-314
[12]   3D time-resolved contrast-enhanced MR DSA: Advantages and tradeoffs [J].
Mistretta, CA ;
Grist, TM ;
Korosec, FR ;
Frayne, R ;
Peters, DC ;
Mazaheri, Y ;
Carroll, TJ .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (04) :571-581
[13]   Peripheral MR angiography: Separation of arteries from veins with flow-spoiled gradient pulses in electrocardiography-triggered three-dimensional half-Fourier fast spin-echo imaging [J].
Miyazaki, M ;
Takai, H ;
Sugiura, S ;
Wada, H ;
Kuwahara, R ;
Urata, L .
RADIOLOGY, 2003, 227 (03) :890-896
[14]   Peripheral arterial disease: Meta-analysis of the diagnostic performance of MR angiography [J].
Nelemans, PJ ;
Leiner, T ;
de Vet, HCW ;
van Engelshoven, JMA .
RADIOLOGY, 2000, 217 (01) :105-114
[15]   MR ANGIOGRAPHY BY SELECTIVE INVERSION RECOVERY [J].
NISHIMURA, DG ;
MACOVSKI, A ;
PAULY, JM ;
CONOLLY, SM .
MAGNETIC RESONANCE IN MEDICINE, 1987, 4 (02) :193-202
[16]   DYNAMIC GADOLINIUM-ENHANCED 3-DIMENSIONAL ABDOMINAL MR ARTERIOGRAPHY [J].
PRINCE, MR ;
YUCEL, EK ;
KAUFMAN, JA ;
HARRISON, DC ;
GELLER, SC .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (06) :877-881
[17]  
Pruessmann KP, 1999, MAGNET RESON MED, V42, P952, DOI 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO
[18]  
2-S
[19]   Quantitative imaging of magnetization transfer exchange and relaxation properties in vivo using MRI [J].
Sled, JG ;
Pike, GB .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (05) :923-931
[20]   Cardiac-gated two-dimensional phase-contrast MR angiography of lower extremity occlusive disease [J].
Steffens, CJ ;
Link, J ;
MullerHulsbeck, S ;
Freund, M ;
Brinkmann, G ;
Heller, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (03) :749-754