Non-Contrast-Enhanced Four-Dimensional (4D) Intracranial MR Angiography: A Feasibility Study

被引:48
作者
Bi, Xiaoming [1 ]
Weale, Peter [1 ]
Schmitt, Peter [2 ]
Zuehlsdorff, Sven [1 ]
Jerecic, Renate [1 ]
机构
[1] Siemens Med Solut USA Inc, Chicago, IL USA
[2] Siemens AG Healthcare, Erlangen, Germany
关键词
magnetic resonance angiography; non-contrast-enhanced; time-resolved; intracranial arteries; hemodynamics; flow visualization; SUBSECOND-TEMPORAL-RESOLUTION; ARTERIOVENOUS-MALFORMATIONS; INVERSION; DSA;
D O I
10.1002/mrm.22220
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
T-1-shortening contrast agents have been widely used in time-resolved magnetic resonance angiography. To match imaging data acquisition with the short time period of the first pass of contrast agent, temporal resolution and/or spatial resolution have to be compromised in many cases. In this study, a novel non-contrast-enhanced technique was developed for time-resolved magnetic resonance angiography. Alternating magnetization preparation was applied in two consecutive acquisitions of each measurement to eliminate the need for contrast media. Without the constraint of contrast media kinetics, temporal resolution is drastically improved from the order of a second as in conventional contrast-enhanced approach to tens of milliseconds (50.9 msec) in this study, without compromising spatial resolution. Initial results from volunteer studies demonstrate the feasibility of this method to depict anatomic structure and dynamic filling of main vessels in the head. Magn Reson Med 63:835-841, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:835 / 841
页数:7
相关论文
共 21 条
  • [1] Cerebral arteriovenous malformations: morphologic evaluation by ultrashort 3D gadolinium-enhanced MR angiography
    Duran, M
    Schoenberg, SO
    Yuh, WTC
    Knopp, MV
    van Kaick, G
    Essig, M
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (12) : 2957 - 2964
  • [2] SIGNAL TARGETING WITH ALTERNATING RADIOFREQUENCY (STAR) SEQUENCES - APPLICATION TO MR-ANGIOGRAPHY
    EDELMAN, RR
    SIEWERT, B
    ADAMIS, M
    GAA, T
    LAUB, G
    WIELOPOLSKI, P
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (02) : 233 - 238
  • [3] Comparison of MR angiography and conventional anglography in the investigation of intracranial arteriovenous malformations and aneurysms in children
    Fasulakis, S
    Andronikou, S
    [J]. PEDIATRIC RADIOLOGY, 2003, 33 (06) : 378 - 384
  • [4] Thorax: Low-dose contrast-enhanced three-dimensional MR angiography with subsecond temporal resolution - Initial results
    Finn, JP
    Baskaran, V
    Carr, JC
    McCarthy, RM
    Pereles, FS
    Kroeker, R
    Laub, GA
    [J]. RADIOLOGY, 2002, 224 (03) : 896 - 904
  • [5] Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA)
    Griswold, MA
    Jakob, PM
    Heidemann, RM
    Nittka, M
    Jellus, V
    Wang, JM
    Kiefer, B
    Haase, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) : 1202 - 1210
  • [6] Haacke E.M., 1999, Magnetic Resonance Imaging: Physical Principles and Sequence Design
  • [7] Cerebral arteriovenous malformation: Spetzler-Martin classification at subsecond-temporal-resolution four-dimensional MR angiography compared with that at DSA
    Hadizadeh, Dariusch R.
    von Falkenhausen, Marcus
    Gieseke, Juergen
    Meyer, Bernhard
    Urbach, Horst
    Hoogeveen, Romhild
    Schild, Hans H.
    Willinek, Winfried A.
    [J]. RADIOLOGY, 2008, 246 (01) : 205 - 213
  • [8] Time-resolved contrast-enhanced 3D MR angiography
    Korosec, FR
    Frayne, R
    Grist, TM
    Mistretta, CA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) : 345 - 351
  • [9] Laub G A, 1995, Magn Reson Imaging Clin N Am, V3, P391
  • [10] Nephrogenic systemic fibrosis: Suspected causative role of gadodiamide used for contrast-enhanced magnetic resonance imaging
    Marckmann, Peter
    Skov, Lone
    Rossen, Kristian
    Dupont, Anders
    Damholt, Mette Brimnes
    Heaf, James Goya
    Thomsen, Henrik S.
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2006, 17 (09): : 2359 - 2362