The rheologic properties of erythrocytes: a study using an automated rheoscope

被引:10
作者
Bransky, Avishay [1 ]
Korin, Natanel
Leshansky, Alexander
Lanir, Naomi
Nemirovski, Yael
Dinnar, Uri
机构
[1] Technion, Biomed Engn, IL-32000 Haifa, Israel
[2] Technion, Chem Engn, IL-32000 Haifa, Israel
[3] Rambam Med Ctr, Lab Hematol, IL-31096 Haifa, Israel
关键词
RBC; lateral migration; erythrocytes; microchannel; rheoscope;
D O I
10.1007/s00397-006-0146-7
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Red blood cells (RBCs) suspended in a high-viscosity medium were filmed while flowing through a microchannel using an automated rheoscope. Under these conditions, erythrocytes take different orientations and undergo varying deformation according to their location in the velocity profile. Measurements of the mean deformation at several distances from the center of the microchannel at a constant flow rate were acquired for normal and thalassemia erythrocytes. The measurements demonstrate how diagnosis can be made based on a single flow rate in contrast to conventional methods where shear is mechanically controlled. The spatial distribution and velocity of RBCs and rigid microspheres (1 mu m) were measured. The maximum slip velocity was found to be linearly correlated to the flow rate for both cells and microspheres. RBCs showed enhanced inward lateral migration compared to the rigid spheres, which is attributed to RBC deformation. The results demonstrate the coupling between RBC mechanical properties and their motion in microvessels.
引用
收藏
页码:621 / 627
页数:7
相关论文
共 26 条
[1]  
[Anonymous], 1928, KLIN WOCHENSCHR
[2]  
BESSIS M, 1980, BLOOD CELLS, V6, P315
[3]   An automated cell analysis sensing system based on a microfabricated rheoscope for the study of red blood cells physiology [J].
Bransky, Avishay ;
Korin, Natanel ;
Nemirovski, Yael ;
Dinnar, Uri .
BIOSENSORS & BIOELECTRONICS, 2006, 22 (02) :165-169
[4]   Biotechnology at low Reynolds numbers [J].
Brody, JP ;
Yager, P ;
Goldstein, RE ;
Austin, RH .
BIOPHYSICAL JOURNAL, 1996, 71 (06) :3430-3441
[5]   Measurement of the distribution of red blood cell deformability using an automated rheoscope [J].
Dobbe, JGG ;
Streekstra, GJ ;
Hardeman, MR ;
Ince, C ;
Grimbergen, CA .
CYTOMETRY, 2002, 50 (06) :313-325
[6]   Red blood cell deformability as a predictor of anemia in severe falciparum malaria [J].
Dondorp, AM ;
Angus, BJ ;
Chotivanich, K ;
Silamut, K ;
Ruangveerayuth, R ;
Hardeman, MR ;
Kager, PA ;
Vreeken, J ;
White, NJ .
AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 1999, 60 (05) :733-737
[7]  
Engstrom KG, 1996, CYTOMETRY, V23, P22, DOI 10.1002/(SICI)1097-0320(19960101)23:1<22::AID-CYTO4>3.0.CO
[8]  
2-O
[9]   The viscosity of the blood in narrow capillary tubes [J].
Fahraeus, R ;
Lindqvist, T .
AMERICAN JOURNAL OF PHYSIOLOGY, 1931, 96 (03) :562-568
[10]   Parallel microchannel-based measurements of individual erythrocyte areas and volumes [J].
Gifford, SC ;
Frank, MG ;
Derganc, J ;
Gabel, C ;
Austin, RH ;
Yoshida, T ;
Bitensky, MW .
BIOPHYSICAL JOURNAL, 2003, 84 (01) :623-633