Accelerated cardiac cine MRI using locally low rank and finite difference constraints

被引:43
|
作者
Miao, Xin [1 ]
Lingala, Sajan Goud [2 ]
Guo, Yi [2 ]
Jao, Terrence [2 ]
Usman, Muhammad [3 ]
Prieto, Claudia [3 ]
Nayak, Krishna S. [1 ,2 ]
机构
[1] Univ So Calif, Dept Biomed Engn, Los Angeles, CA 90089 USA
[2] Univ So Calif, Ming Hsieh Dept Elect Engn, Los Angeles, CA USA
[3] Kings Coll London, Div Imaging Sci & Biomed Engn, London WC2R 2LS, England
关键词
Cardiac cine MRI; Sparse sampling; Constrained reconstruction; Locally low rank; Compressed sensing; Parallel imaging; PRINCIPAL COMPONENT ANALYSIS; K-T FOCUSS; DYNAMIC MRI; IMAGE QUALITY; EXPLOITING SPARSITY; RADIAL K; RECONSTRUCTION; FRAMEWORK; SENSE; COIL;
D O I
10.1016/j.mri.2016.03.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the potential value of combining multiple constraints for highly accelerated cardiac cine MRI. Methods: A locally low rank (LLR) constraint and a temporal finite difference (FD) constraint were combined to reconstruct cardiac cine data from highly undersampled measurements. Retrospectively undersampled 2D Cartesian reconstructions were quantitatively evaluated against fully-sampled data using normalized root mean square error, structural similarity index (SSIM) and high frequency error norm (HFEN). This method was also applied to 2D golden-angle radial real-time imaging to facilitate single breath-hold whole-heart cine (12 short-axis slices, 9-13 s single breath hold). Reconstruction was compared against state-of-the-art constrained reconstruction methods: LLR, FD, and k-t SLR. Results: At 10 to 60 spokes/frame, LLR + FD better preserved fine structures and depicted myocardial motion with reduced spatio-temporal blurring in comparison to existing methods. LLR yielded higher SSIM ranking than FD; FD had higher HFEN ranking than LLR. LLR + FD combined the complimentary advantages of the two, and ranked the highest in all metrics for all retrospective undersampled cases. Single breath-hold multi-slice cardiac cine with prospective undersampling was enabled with in-plane spatio-temporal resolutions of 2 x 2 mm(2) and 40 ms. Conclusion: Highly accelerated cardiac cine is enabled by the combination of 2D undersampling and the synergistic use of LLR and FD constraints. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:707 / 714
页数:8
相关论文
共 50 条
  • [41] Motion Correction Using Coil Arrays (MOCCA) for Free-Breathing Cardiac Cine MRI
    Hu, Peng
    Hong, Susie
    Moghari, Mehdi H.
    Goddu, Beth
    Goepfert, Lois
    Kissinger, Kraig V.
    Hauser, Thomas H.
    Manning, Warren J.
    Nezafat, Reza
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (02) : 467 - 475
  • [42] Accelerated High-Dimensional MR Imaging With Sparse Sampling Using Low-Rank Tensors
    He, Jingfei
    Liu, Qiegen
    Christodoulou, Anthony G.
    Ma, Chao
    Lam, Fan
    Liang, Zhi-Pei
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (09) : 2119 - 2129
  • [43] Super Resolution of Cardiac Cine MRI Sequences Using Deep Learning
    Basty, Nicolas
    Grau, Vicente
    IMAGE ANALYSIS FOR MOVING ORGAN, BREAST, AND THORACIC IMAGES, 2018, 11040 : 23 - 31
  • [44] Conflict-Cost Based Random Sampling Design for Parallel MRI with Low Rank Constraints
    Kim, Wan
    Zhou, Yihang
    Lyu, Jingyuan
    Ying, Leslie
    COMPRESSIVE SENSING IV, 2015, 9484
  • [45] Improved Subspace Estimation for Low-Rank Model-Based Accelerated Cardiac Imaging
    Christodoulou, Anthony G.
    Hitchens, T. Kevin
    Wu, Yijen L.
    Ho, Chien
    Liang, Zhi-Pei
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (09) : 2451 - 2457
  • [46] Accelerated MRI Reconstruction With Separable and Enhanced Low-Rank Hankel Regularization
    Zhang, Xinlin
    Lu, Hengfa
    Guo, Di
    Lai, Zongying
    Ye, Huihui
    Peng, Xi
    Zhao, Bo
    Qu, Xiaobo
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2022, 41 (09) : 2486 - 2498
  • [47] Dynamic MRI Reconstruction Using Nonlocal Low-Rank Constraints Based On The Deformation Corrected Signal
    Sun, Mei
    Tao, Jinxu
    Ye, Zhongfu
    Qiu, Bensheng
    Xu, Jinzhang
    PROCEEDINGS OF 2017 8TH IEEE INTERNATIONAL CONFERENCE ON SOFTWARE ENGINEERING AND SERVICE SCIENCE (ICSESS 2017), 2017, : 930 - 934
  • [48] A Novel Reconstruction Approach Combining Global and Local Low-rank Constraints for Undersampled Dynamic MRI
    Xi, Changfeng
    Tao, Jinxu
    Qiu, Bensheng
    Ye, Zhongfu
    Xu, Jinzhang
    CURRENT MEDICAL IMAGING REVIEWS, 2018, 14 (05) : 732 - 743
  • [49] Improved Motion Correction in Dynamic Contrast-Enhanced MRI Using Low Rank With Soft Weighting
    Zhang, Jichang
    Najeeb, Faisal
    Wang, Yulin
    Wang, Xinpei
    Xu, Pengfei
    Omer, Hammad
    Zheng, Jianjun
    Zhang, Jingfeng
    Francis, Sue
    Glover, Paul
    Bowtell, Richard
    Meersmann, Thomas
    Wang, Chengbo
    IEEE ACCESS, 2025, 13 : 1867 - 1881
  • [50] Motion-aligned 4D-MRI reconstruction using higher degree total variation and locally low-rank regularization
    Li, Peng
    Chen, Jialei
    Nan, Dong
    Zou, Jing
    Lin, Disi
    Hu, Yue
    MAGNETIC RESONANCE IMAGING, 2022, 93 : 97 - 107