Accelerated cardiac cine MRI using locally low rank and finite difference constraints

被引:43
|
作者
Miao, Xin [1 ]
Lingala, Sajan Goud [2 ]
Guo, Yi [2 ]
Jao, Terrence [2 ]
Usman, Muhammad [3 ]
Prieto, Claudia [3 ]
Nayak, Krishna S. [1 ,2 ]
机构
[1] Univ So Calif, Dept Biomed Engn, Los Angeles, CA 90089 USA
[2] Univ So Calif, Ming Hsieh Dept Elect Engn, Los Angeles, CA USA
[3] Kings Coll London, Div Imaging Sci & Biomed Engn, London WC2R 2LS, England
关键词
Cardiac cine MRI; Sparse sampling; Constrained reconstruction; Locally low rank; Compressed sensing; Parallel imaging; PRINCIPAL COMPONENT ANALYSIS; K-T FOCUSS; DYNAMIC MRI; IMAGE QUALITY; EXPLOITING SPARSITY; RADIAL K; RECONSTRUCTION; FRAMEWORK; SENSE; COIL;
D O I
10.1016/j.mri.2016.03.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the potential value of combining multiple constraints for highly accelerated cardiac cine MRI. Methods: A locally low rank (LLR) constraint and a temporal finite difference (FD) constraint were combined to reconstruct cardiac cine data from highly undersampled measurements. Retrospectively undersampled 2D Cartesian reconstructions were quantitatively evaluated against fully-sampled data using normalized root mean square error, structural similarity index (SSIM) and high frequency error norm (HFEN). This method was also applied to 2D golden-angle radial real-time imaging to facilitate single breath-hold whole-heart cine (12 short-axis slices, 9-13 s single breath hold). Reconstruction was compared against state-of-the-art constrained reconstruction methods: LLR, FD, and k-t SLR. Results: At 10 to 60 spokes/frame, LLR + FD better preserved fine structures and depicted myocardial motion with reduced spatio-temporal blurring in comparison to existing methods. LLR yielded higher SSIM ranking than FD; FD had higher HFEN ranking than LLR. LLR + FD combined the complimentary advantages of the two, and ranked the highest in all metrics for all retrospective undersampled cases. Single breath-hold multi-slice cardiac cine with prospective undersampling was enabled with in-plane spatio-temporal resolutions of 2 x 2 mm(2) and 40 ms. Conclusion: Highly accelerated cardiac cine is enabled by the combination of 2D undersampling and the synergistic use of LLR and FD constraints. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:707 / 714
页数:8
相关论文
共 50 条
  • [31] Highly accelerated real-time cardiac cine MRI using k-t SPARSE-SENSE
    Feng, Li
    Srichai, Monvadi B.
    Lim, Ruth P.
    Harrison, Alexis
    King, Wilson
    Adluru, Ganesh
    Dibella, Edward V. R.
    Sodickson, Daniel K.
    Otazo, Ricardo
    Kim, Daniel
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (01) : 64 - 74
  • [32] Accelerated Cardiac MRI Cine with Use of Resolution Enhancement Generative Adversarial Inline Neural Network
    Yoon, Siyeop
    Nakamori, Shiro
    Amyar, Amine
    Assana, Salah
    Cirillo, Julia
    Morales, Manuel A.
    Chow, Kelvin
    Bi, Xiaoming
    Pierce, Patrick
    Goddu, Beth
    Rodriguez, Jennifer
    Ngo, Long H.
    Manning, Warren J.
    Nezafat, Reza
    RADIOLOGY, 2023, 307 (05) : e222878
  • [33] Reconstruction of Undersampled Big Dynamic MRI Data Using Non-Convex Low-Rank and Sparsity Constraints
    Liu, Ryan Wen
    Shi, Lin
    Yu, Simon Chun Ho
    Xiong, Naixue
    Wang, Defeng
    SENSORS, 2017, 17 (03)
  • [34] Accelerating cardiac cine MRI using a deep learning-based ESPIRiT reconstruction
    Sandino, Christopher M.
    Lai, Peng
    Vasanawala, Shreyas S.
    Cheng, Joseph Y.
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (01) : 166 - 181
  • [35] Accelerated Phase-Contrast Cine MRI Using k-t SPARSE-SENSE
    Kim, Daniel
    Dyvorne, Hadrien A.
    Otazo, Ricardo
    Feng, Li
    Sodickson, Daniel K.
    Lee, Vivian S.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (04) : 1054 - 1064
  • [36] A novel low-rank model for MRI using the redundant wavelet tight frame
    Chen, Zhen
    Fu, Yuli
    Xiang, Youjun
    Xu, Junwei
    Rong, Rong
    NEUROCOMPUTING, 2018, 289 : 180 - 187
  • [37] Using learned under-sampling pattern for increasing speed of cardiac cine MRI based on compressive sensing principles
    Zamani, Pooria
    Kayvanrad, Mohammad
    Soltanian-Zadeh, Hamid
    EURASIP JOURNAL ON ADVANCES IN SIGNAL PROCESSING, 2012,
  • [38] Automated parameter selection for accelerated MRI reconstruction via low-rank modeling of local k-space neighborhoods
    Ilicak, Efe
    Saritas, Emine Ulku
    Cukur, Tolga
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2023, 33 (02): : 203 - 219
  • [39] Highly-accelerated self-gated free-breathing 3D cardiac cine MRI: validation in assessment of left ventricular function
    Liu, Jing
    Feng, Li
    Shen, Hsin-Wei
    Zhu, Chengcheng
    Wang, Yan
    Mukai, Kanae
    Brooks, Gabriel C.
    Ordovas, Karen
    Saloner, David
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2017, 30 (04) : 337 - 346
  • [40] RECENT PROGRESSES OF ACCELERATED MRI USING ANNIHILATING FILTER-BASED LOW-RANK INTERPOLATION
    Jin, Kyong Hwan
    Lee, Dongwook
    Lee, Juyoung
    Ye, Jong Chul
    2016 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2016, : 968 - 972