Accelerated cardiac cine MRI using locally low rank and finite difference constraints

被引:43
|
作者
Miao, Xin [1 ]
Lingala, Sajan Goud [2 ]
Guo, Yi [2 ]
Jao, Terrence [2 ]
Usman, Muhammad [3 ]
Prieto, Claudia [3 ]
Nayak, Krishna S. [1 ,2 ]
机构
[1] Univ So Calif, Dept Biomed Engn, Los Angeles, CA 90089 USA
[2] Univ So Calif, Ming Hsieh Dept Elect Engn, Los Angeles, CA USA
[3] Kings Coll London, Div Imaging Sci & Biomed Engn, London WC2R 2LS, England
关键词
Cardiac cine MRI; Sparse sampling; Constrained reconstruction; Locally low rank; Compressed sensing; Parallel imaging; PRINCIPAL COMPONENT ANALYSIS; K-T FOCUSS; DYNAMIC MRI; IMAGE QUALITY; EXPLOITING SPARSITY; RADIAL K; RECONSTRUCTION; FRAMEWORK; SENSE; COIL;
D O I
10.1016/j.mri.2016.03.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the potential value of combining multiple constraints for highly accelerated cardiac cine MRI. Methods: A locally low rank (LLR) constraint and a temporal finite difference (FD) constraint were combined to reconstruct cardiac cine data from highly undersampled measurements. Retrospectively undersampled 2D Cartesian reconstructions were quantitatively evaluated against fully-sampled data using normalized root mean square error, structural similarity index (SSIM) and high frequency error norm (HFEN). This method was also applied to 2D golden-angle radial real-time imaging to facilitate single breath-hold whole-heart cine (12 short-axis slices, 9-13 s single breath hold). Reconstruction was compared against state-of-the-art constrained reconstruction methods: LLR, FD, and k-t SLR. Results: At 10 to 60 spokes/frame, LLR + FD better preserved fine structures and depicted myocardial motion with reduced spatio-temporal blurring in comparison to existing methods. LLR yielded higher SSIM ranking than FD; FD had higher HFEN ranking than LLR. LLR + FD combined the complimentary advantages of the two, and ranked the highest in all metrics for all retrospective undersampled cases. Single breath-hold multi-slice cardiac cine with prospective undersampling was enabled with in-plane spatio-temporal resolutions of 2 x 2 mm(2) and 40 ms. Conclusion: Highly accelerated cardiac cine is enabled by the combination of 2D undersampling and the synergistic use of LLR and FD constraints. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:707 / 714
页数:8
相关论文
共 50 条
  • [21] Bi-smooth constraints for accelerated dynamic MRI with low-rank plus sparse tensor decomposition
    He, Jingfei
    Liu, Xiaotong
    Luan, Nannan
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 82
  • [22] Low-Rank Optimization Algorithm for Accelerated Dynamic MRI
    Yang Min
    PROCEEDINGS OF THE 28TH CHINESE CONTROL AND DECISION CONFERENCE (2016 CCDC), 2016, : 1956 - 1960
  • [23] Fetal cardiac cine imaging using highly accelerated dynamic MRI with retrospective motion correction and outlier rejection
    van Amerom, Joshua F. P.
    Lloyd, David F. A.
    Price, Anthony N.
    Murgasova, Maria Kuklisova
    Aljabar, Paul
    Malik, Shaihan J.
    Lohezic, Maelene
    Rutherford, Mary A.
    Pushparajah, Kuberan
    Razavi, Reza
    Hajnal, Joseph V.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (01) : 327 - 338
  • [24] Cine Cardiac MRI Motion Artifact Reduction Using a Recurrent Neural Network
    Lyu, Qing
    Shan, Hongming
    Xie, Yibin
    Kwan, Alan C.
    Otaki, Yuka
    Kuronuma, Keiichiro
    Li, Debiao
    Wang, Ge
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (08) : 2170 - 2181
  • [25] Fast Low Rank Column-Wise Compressive Sensing for Accelerated Dynamic MRI
    Babu, Silpa
    Lingala, Sajan Goud
    Vaswani, Namrata
    IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2023, 9 : 409 - 424
  • [26] Considering low-rank, sparse and gas-inflow effects constraints for accelerated pulmonary dynamic hyperpolarized 129Xe MRI
    Xiao, Sa
    Deng, He
    Duan, Caohui
    Xie, Junshuai
    Zhang, Huiting
    Sun, Xianping
    Ye, Chaohui
    Zhou, Xin
    JOURNAL OF MAGNETIC RESONANCE, 2018, 290 : 29 - 37
  • [27] FAST LOW RANK COLUMN-WISE COMPRESSIVE SENSING FOR ACCELERATED DYNAMIC MRI
    Babu, Silpa
    Nayer, Seyedehsara
    Lingala, Sajan Goud
    Vaswani, Namrata
    2022 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2022, : 1346 - 1350
  • [28] One-Dimensional Deep Low-Rank and Sparse Network for Accelerated MRI
    Wang, Zi
    Qian, Chen
    Guo, Di
    Sun, Hongwei
    Li, Rushuai
    Zhao, Bo
    Qu, Xiaobo
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2023, 42 (01) : 79 - 90
  • [29] Computationally Efficient Implicit Training Strategy for Unrolled Networks (IMUNNE): A Preliminary Analysis Using Accelerated Real-Time Cardiac Cine MRI
    Iakovlev, Nikolay
    Schiffers, Florian A.
    Tapia, Santiago L.
    Shen, Daming
    Hong, Kyungpyo
    Markl, Michael
    Lee, Daniel C.
    Katsaggelos, Aggelos K.
    Kim, Daniel
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2025, 72 (01) : 187 - 197
  • [30] Accelerated cardiac cine MRI using spatiotemporal correlation-based hybrid plug-and-play priors (SEABUS)
    Zhu, Qingyong
    Liu, Bei
    Cui, Zhuo-Xu
    Cheng, Jing
    Cao, Chentao
    Liu, Yuanyuan
    Liang, Dong
    Zhu, Yanjie
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (21)