Accelerated cardiac cine MRI using locally low rank and finite difference constraints

被引:43
|
作者
Miao, Xin [1 ]
Lingala, Sajan Goud [2 ]
Guo, Yi [2 ]
Jao, Terrence [2 ]
Usman, Muhammad [3 ]
Prieto, Claudia [3 ]
Nayak, Krishna S. [1 ,2 ]
机构
[1] Univ So Calif, Dept Biomed Engn, Los Angeles, CA 90089 USA
[2] Univ So Calif, Ming Hsieh Dept Elect Engn, Los Angeles, CA USA
[3] Kings Coll London, Div Imaging Sci & Biomed Engn, London WC2R 2LS, England
关键词
Cardiac cine MRI; Sparse sampling; Constrained reconstruction; Locally low rank; Compressed sensing; Parallel imaging; PRINCIPAL COMPONENT ANALYSIS; K-T FOCUSS; DYNAMIC MRI; IMAGE QUALITY; EXPLOITING SPARSITY; RADIAL K; RECONSTRUCTION; FRAMEWORK; SENSE; COIL;
D O I
10.1016/j.mri.2016.03.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the potential value of combining multiple constraints for highly accelerated cardiac cine MRI. Methods: A locally low rank (LLR) constraint and a temporal finite difference (FD) constraint were combined to reconstruct cardiac cine data from highly undersampled measurements. Retrospectively undersampled 2D Cartesian reconstructions were quantitatively evaluated against fully-sampled data using normalized root mean square error, structural similarity index (SSIM) and high frequency error norm (HFEN). This method was also applied to 2D golden-angle radial real-time imaging to facilitate single breath-hold whole-heart cine (12 short-axis slices, 9-13 s single breath hold). Reconstruction was compared against state-of-the-art constrained reconstruction methods: LLR, FD, and k-t SLR. Results: At 10 to 60 spokes/frame, LLR + FD better preserved fine structures and depicted myocardial motion with reduced spatio-temporal blurring in comparison to existing methods. LLR yielded higher SSIM ranking than FD; FD had higher HFEN ranking than LLR. LLR + FD combined the complimentary advantages of the two, and ranked the highest in all metrics for all retrospective undersampled cases. Single breath-hold multi-slice cardiac cine with prospective undersampling was enabled with in-plane spatio-temporal resolutions of 2 x 2 mm(2) and 40 ms. Conclusion: Highly accelerated cardiac cine is enabled by the combination of 2D undersampling and the synergistic use of LLR and FD constraints. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:707 / 714
页数:8
相关论文
共 50 条
  • [1] Highly Accelerated Cardiac Cine parallel MRI using Low-Rank Matrix Completion and Partial Separability Model
    Lyu, Jingyuan
    Nakarmi, Ukash
    Zhang, Chaoyi
    Ying, Leslie
    COMPRESSIVE SENSING V: FROM DIVERSE MODALITIES TO BIG DATA ANALYTICS, 2016, 9857
  • [2] Accelerated Cardiac Diffusion Tensor Imaging Using Joint Low-Rank and Sparsity Constraints
    Ma, Sen
    Nguyen, Christopher T.
    Christodoulou, Anthony G.
    Luthringer, Daniel
    Kobashigawa, Jon
    Lee, Sang-Eun
    Chang, Hyuk-Jae
    Li, Debiao
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2018, 65 (10) : 2219 - 2230
  • [3] Dynamic cardiac MRI reconstruction using motion aligned locally low rank tensor (MALLRT)
    Liu, Fan
    Li, Dongxiao
    Jin, Xinyu
    Qiu, Wenyuan
    Xia, Qi
    Sun, Bin
    MAGNETIC RESONANCE IMAGING, 2020, 66 : 104 - 115
  • [4] Accelerated cardiac cine magnetic resonance imaging using deep low-rank plus sparse network: validation in patients
    Yan, Chenyuan
    Liu, Yuanyuan
    Wang, Che
    Fan, Weixiong
    Zhu, Yanjie
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (07) : 5131 - 5143
  • [5] k-t FASTER: Acceleration of functional MRI data acquisition using low rank constraints
    Chiew, Mark
    Smith, Stephen M.
    Koopmans, Peter J.
    Graedel, Nadine N.
    Blumensath, Thomas
    Miller, Karla L.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (02) : 353 - 364
  • [6] Acceleration of Perfusion MRI Using Locally Low-Rank Plus Sparse Model
    Dankova, Marie
    Rajmic, Pavel
    Jirik, Radovan
    LATENT VARIABLE ANALYSIS AND SIGNAL SEPARATION, LVA/ICA 2015, 2015, 9237 : 514 - 521
  • [7] Unsupervised reconstruction of accelerated cardiac cine MRI using neural fields
    Catalán, Tabita
    Courdurier, Matías
    Osses, Axel
    Fotaki, Anastasia
    Botnar, René
    Sahli-Costabal, Francisco
    Prieto, Claudia
    Computers in Biology and Medicine, 2025, 185
  • [8] ADAPTIVE LOCALLY LOW RANK AND SPARSITY CONSTRAINED RECONSTRUCTION FOR ACCELERATED DYNAMIC MRI
    Kafali, Sevgi Gokce
    Shih, Shu-Fu
    Ruan, Dan
    Wu, Holden H.
    2020 IEEE 17TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2020), 2020, : 930 - 934
  • [9] Compressed sensing reconstruction of cardiac cine MRI using golden angle spiral trajectories
    Tolouee, Azar
    Alirezaie, Javad
    Babyn, Paul
    JOURNAL OF MAGNETIC RESONANCE, 2015, 260 : 10 - 19
  • [10] Motion Adaptive Patch-Based Low-Rank Approach for Compressed Sensing Cardiac Cine MRI
    Yoon, Huisu
    Kim, Kyung Sang
    Kim, Daniel
    Bresler, Yoram
    Ye, Jong Chul
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (11) : 2069 - 2085