Preventing lens epithelial cell migration using intraocular lenses with sharp rectangular edges

被引:175
作者
Nishi, O
Nishi, K
Wickström, K
机构
[1] Nishi Eye Hosp, Higashinari Ku, Osaka 5370025, Japan
[2] Pharmacia & Upjohn, Dept Pharmacol, Uppsala, Sweden
关键词
D O I
10.1016/S0886-3350(00)00426-0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the preventive effect on posterior capsule opacification (PCO) of an acrylic intraocular lens (IOL) and a silicone IOL, both with sharp rectangular optic edges. Setting: Jinshikai Medical Foundation, Nishi Eye Hospital, Osaka, Japan. Methods: After phacoemulsification, an acrylic IOL (AcrySof(R)) was implanted in 1 eye and a silicone IOL (CeeOn 911) in the contralateral eye of 7 rabbits, one of which was omitted from evaluation. Results: The Miyake-Apple view and histopathological findings 3 weeks after surgery revealed that the lens capsule wrapped tightly around the optic edges, conforming to a distinctly sharp bend, with both IOL types in 5 rabbits. Migrating lens epithelial cells (LECs) were inhibited at the site. The AcrySof IOL had a better capsular bend effect in the histological sections, but there was no apparent difference in PCO development between the 2 IOLs. Conclusions: The CeeOn 911 silicone IOL, with sharp rectangular optic edges, showed an effect on preventing PCO that was similar to that of the AcrySof IOL. When a discontinuous capsular bend is created by an IOL with Sharp optic edges, the bend may induce contact inhibition of migrating LECs regardless of the lens' material composition. J Cataract Refract Surg 2000; 26:1543-1549 (C) 2000 ASCRS and ESCRS.
引用
收藏
页码:1543 / 1549
页数:7
相关论文
共 11 条
  • [1] POSTERIOR CAPSULE OPACIFICATION
    APPLE, DJ
    SOLOMON, KD
    TETZ, MR
    ASSIA, EI
    HOLLAND, EY
    LEGLER, UFC
    TSAI, JC
    CASTANEDA, VE
    HOGGATT, JP
    KOSTICK, AMP
    [J]. SURVEY OF OPHTHALMOLOGY, 1992, 37 (02) : 73 - 116
  • [2] POSTERIOR CAPSULAR OPACIFICATION AND INTRAOCULAR-LENS DECENTRATION .1. COMPARISON OF VARIOUS POSTERIOR CHAMBER LENS DESIGNS IMPLANTED IN THE RABBIT MODEL
    HANSEN, SO
    SOLOMON, KD
    MCKNIGHT, GT
    WILBRANDT, TH
    GWIN, TD
    OMORCHOE, DJC
    TETZ, MR
    APPLE, DJ
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1988, 14 (06) : 605 - 613
  • [3] The effect of polymethylmethacrylate, silicone, and polyacrylic intraocular lenses on posterior capsular opacification 3 years after cataract surgery
    Hollick, EJ
    Spalton, DJ
    Ursell, PG
    Pande, MV
    Barman, SA
    Boyce, JF
    Tilling, K
    [J]. OPHTHALMOLOGY, 1999, 106 (01) : 49 - 54
  • [4] Nagata T, 1996, JPN J OPHTHALMOL, V40, P397
  • [5] Adhesiveness of AcrySof to a collagen film
    Nagata, T
    Minakata, A
    Watanabe, I
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (03) : 367 - 370
  • [6] Nishi O, 1998, OPHTHALMIC SURG LAS, V29, P587
  • [7] Preventing posterior capsule opacification by creating a discontinuous sharp bend in the capsule
    Nishi, O
    Nishi, K
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (04) : 521 - 526
  • [8] Adhesion of lens capsule to intraocular lenses of polymethylmethacrylate, silicone, and acrylic foldable materials: an experimental study
    Oshika, T
    Nagata, T
    Ishii, Y
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (05) : 549 - 553
  • [9] Two year clinical study of a soft acrylic intraocular lens
    Oshika, T
    Suzuki, Y
    Kizaki, H
    Yaguchi, S
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (01) : 104 - 109
  • [10] Relationship between intraocular lens biomaterials and posterior capsule opacification
    Ursell, PG
    Spalton, DJ
    Pande, MV
    Hollick, EJ
    Barman, S
    Boyce, J
    Tilling, K
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (03) : 352 - 360