Research on Low-voltage Ride-through Technology of Doubly-fed VSCF Wind Power Generation System

被引:0
|
作者
Bao Wei [1 ]
Yin Zhongdong [1 ]
机构
[1] N China Elect Power Univ, Key Lab Power Syst Protect & Dynam Secur Monitori, Beijing, Peoples R China
来源
ICEET: 2009 INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT TECHNOLOGY, VOL 2, PROCEEDINGS | 2009年
关键词
wind power; voltage dip; low voltage ride-through (LVRT); transient voltage control; rotor-side converter;
D O I
10.1109/ICEET.2009.293
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Currently, some of the variable speed wind turbine on market have some low-voltage through capacity (LVRT), but do not have dynamic reactive power support capacity under fault.DFIG can't provide dynamic voltage support, in addition, as a result of lower terminal voltage, active power can not be completely output, which has impact on safe and stable operation of power grid. Aimed at this problem, this paper discussed how to improve the reactive power support capacity during grid fault such as three-phase voltage dip fault and presented a improved LVRT technology. First, the paper analyzed the transient responses and characteristics of DFIG under grid voltage fault and introduced several control strategies and protection programs of DFIG under voltage dip existing now; then, based on the traditional control strategy, the paper presented a transient voltage control strategy in rotor-side converter which can make DFIG output more reactive power to participate in the transient voltage control of whole grid during voltage dip in grid fault and during the recovery process after the fault to ensure that the terminal voltage of generator maintain the value before fault; finally, the EMTDC / PSCAD simulation showed that adopted transient voltage control strategy in rotor-side converter, the transient voltage control in rotor-side converter can output a large number of reactive power during fault according to the dip depth of terminal voltage to provide dynamic voltage support and insure the fast recovery of grid voltage.
引用
收藏
页码:228 / 231
页数:4
相关论文
共 50 条
  • [1] Proportional-Resonant Control of Doubly-Fed Induction Generator Wind Turbines for Low-Voltage Ride-Through Enhancement
    Yan, Yan
    Wang, Meng
    Song, Zhan-Feng
    Xia, Chang-Liang
    ENERGIES, 2012, 5 (11): : 4758 - 4778
  • [2] Overview of the low voltage ride-through technology for variable speed constant frequency doubly fed wind power generation systems
    Zhejiang University, Hangzhou 310027, China
    Diangong Jishu Xuebao, 2009, 9 (140-146):
  • [3] Analysis on Low Voltage Ride-Through Techniques for Wind Turbines Using Doubly-Fed Induction Generator
    Han Shunjie
    Han Meng
    Han Yue
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [4] A control scheme to enhance low voltage ride-through of brushless doubly-fed induction generators
    Tohidi, S.
    Oraee, H.
    Zolghadri, M. R.
    Rahimi, M.
    WIND ENERGY, 2016, 19 (09) : 1699 - 1712
  • [5] Dynamic Characteristic Analysis of Doubly-fed Induction Generator Low Voltage Ride-through
    Shi, L.
    Chen, N.
    Lu, Q.
    2012 INTERNATIONAL CONFERENCE ON FUTURE ENERGY, ENVIRONMENT, AND MATERIALS, PT C, 2012, 16 : 1526 - 1534
  • [6] Analysis and research of low voltage ride through for doubly fed wind power generator
    Wang, Ding-Guo
    Zhang, Hong-Chao
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2011, 39 (17): : 70 - 73
  • [7] Influence of low-voltage ride-through control techniques on the thermal behavior of power converters applied to wind energy conversion systems based on the doubly-fed induction generator
    de Oliveira, Igor Rodrigues
    Tofoli, Fernando Lessa
    Mendes, Victor Flores
    ELECTRIC POWER SYSTEMS RESEARCH, 2025, 239
  • [8] Analysis and Enhancement of Low-Voltage Ride-Through Capability of Brushless Doubly Fed Induction Generator
    Tohidi, Sajjad
    Oraee, Hashem
    Zolghadri, Mohammad Reza
    Shao, Shiyi
    Tavner, Peter
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (03) : 1146 - 1155
  • [9] Analysis of low voltage ride-through capability and optimal control strategy of doubly-fed wind farms under symmetrical fault
    Li, Botong
    Zheng, Dingchuan
    Li, Bin
    Jiao, Xinru
    Hong, Qiteng
    Ji, Liang
    PROTECTION AND CONTROL OF MODERN POWER SYSTEMS, 2023, 8 (01)
  • [10] Analysis of low voltage ride-through capability and optimal control strategy of doubly-fed wind farms under symmetrical fault
    Botong Li
    Dingchuan Zheng
    Bin Li
    Xinru Jiao
    Qiteng Hong
    Liang Ji
    Protection and Control of Modern Power Systems, 2023, 8