Dosimetric feasibility of moderately hypofractionated/dose escalated radiation therapy for localised prostate cancer with intensity-modulated proton beam therapy using simultaneous integrated boost (SIB-IMPT) and impact of hydrogel prostate-rectum spacer

被引:1
|
作者
Ahmad Khalil, Dalia [1 ]
Jazmati, Danny [1 ]
Geismar, Dirk [1 ]
Wulff, Jorg [1 ]
Baeumer, Christian [1 ]
Kramer, Paul Heinz [1 ]
Steinmeier, Theresa [1 ]
Schulze Schleitthoff, Stefanie [1 ]
Plaude, Sandija [1 ]
Bischoff, Martin [1 ]
Tschirdewahn, Stephan [2 ]
Hadaschik, Boris [2 ]
Timmermann, Beate [1 ,3 ]
机构
[1] Univ Hosp Essen, West German Proton Therapy Ctr Essen WPE, West German Canc Ctr WTZ, Dept Particle Therapy,German Canc Consortium DKTK, Hufelandstr 55, D-45147 Essen, Germany
[2] Univ Duisburg Essen, Univ Hosp Essen, Dept Urol, Essen, Germany
[3] German Canc Consortium DKTK, Essen, Germany
关键词
Proton therapy; Intensity-modulated therapy; Simultaneous integrated boost; Prostate cancer; Hydrogel prostate-rectum spacers; QUALITY-OF-LIFE; DOSE-RATE BRACHYTHERAPY; RANDOMIZED-TRIAL; ACUTE TOXICITY; NON-INFERIORITY; RADIOTHERAPY; FRACTIONATION; OUTCOMES; VOLUME; IMRT;
D O I
10.1186/s13014-022-02025-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose To examine the dosimetric feasibility of hypofractionated/dose escalated radiation therapy in patients with localized prostate carcinoma using simultaneous integrated boost intensity-modulated proton beam therapy (SIB-IMPT) in absence or presence of prostate-rectum spacer. Methods IMPT technique was implemented in 23 patients with intermediate- and high-risk prostate cancer treated at West German Proton Therapy Centre from March 2016 till June 2018, using SIB technique prescribing 60 GyRBE and 72 GyRBE in 30 fractions to PTV1 (prostate and seminal vesicle) and PTV2 boost (prostate and proximal seminal vesicle), respectively. In 15 patients, a transperineal injection of hydrogel was applied prior to radiotherapy to increase the distance between prostate and rectum. Planning and all treatments were performed with a 120 ml fluid-filled endorectal balloon customised daily for each patient. For each patient, 2 lateral IMPT beams were implemented taking a field-specific range uncertainty (RU) into account. Dose volume histograms (DVH) were analyzed for PTV2, PTV2 with range uncertainty margin (PTV2RU), rectum, bladder, right/left femoral heads, and penile bulb. For late rectal toxicities, the normal tissue complication probabilities (NTCP) were calculated using different biological models. A DVH- and NTCP-based dosimetric comparison was carried out between non-spacer and spacer groups. Results For the 23 patients, high-quality plans could be achieved for target volume and for other organs at risk (OARs). For PTV2, the V-107% was 0% and the D-max did not exceed 106.2% of the prescribed dose. The volume PTV2RU covered by 95% of the dose ranged from 96.16 to 99.95%. The conformality index for PTV2RU was 1.12 +/- 0.057 and the homogeneity index (HI) was 1.04 +/- 0.014. Rectum D-max and rectal volume receiving 73-50 Gy could be further reduced for the spacer-group. Significant reductions in mean and median rectal NTCPs (stenosis/necrosis, late rectal bleeding >= 2, and late rectal toxicities >= 3) were predicted for the spacer group in comparison to the non-spacer group. Conclusion Hypofractionated/dose escalated radiotherapy with SIB-IMPT is dosimetrically feasible. Further reduction of the rectal volumes receiving high and medium dose levels (73-50 Gy) and rectal NTCP could be achieved through injection of spacers between rectum and prostate.
引用
收藏
页数:12
相关论文
共 22 条
  • [21] Assessing the feasibility of volumetric-modulated arc therapy using simultaneous integrated boost (SIB-VMAT): An analysis for complex head-neck, high-risk prostate and rectal cancer cases
    Cilia, Savino
    Deodato, Francesco
    Digesu, Cinzia
    Macchia, Gabriella
    Picardi, Vincenzo
    Ferro, Marica
    Sallustio, Giuseppina
    De Spirito, Marco
    Piermattei, Angelo
    Morganti, Alessio G.
    MEDICAL DOSIMETRY, 2014, 39 (01) : 108 - 116
  • [22] Real-world comparative outcomes and toxicities after definitive radiotherapy using proton beam therapy versus intensity-modulated radiation therapy for prostate cancer: a retrospective, single-institutional analysis
    Ishikawa, Yojiro
    Suzuki, Motohisa
    Yamaguchi, Hisashi
    Seto, Ichiro
    Machida, Masanori
    Takagawa, Yoshiaki
    Azami, Yusuke
    Dai, Yuntao
    Sulaiman, Nor Shazrina
    Teramura, Satoshi
    Narita, Yuki
    Kato, Takahiro
    Kikuchi, Yasuyuki
    Fukaya, Yasuo
    Murakami, Masao