Simple interface for capillary electrophoresis-inductively coupled plasma atomic emission spectrometry

被引:30
作者
Deng, BY [1 ]
Chan, WT [1 ]
机构
[1] Univ Hong Kong, Dept Chem, Hong Kong, Hong Kong, Peoples R China
关键词
interfaces; CE-ICP; detection; electrophoresis; instrumentation; metal cations; metal complexes; inorganic anions;
D O I
10.1016/S0021-9673(00)00622-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple interface has been developed to couple capillary electrophoresis (CE) to inductively coupled plasma atomic emission spectrometry (ICP-AES) for metal speciation. A concentric glass nebulizer with elongated tip is used as the CE-ICP interface. The CE capillary is the central tube of the nebulizer. A platinum wire is wrapped across the exit end of the CE capillary to provide electrical connection to the CE power supply. No sheath flow of buffer solution is needed. A simple cooling system has also been developed. A peristaltic pump circulates water through a plastic tube that encloses the section of the CE capillary between the CE instrument and the ICP spectrometer. Characteristics of the CE-ICP interface, e.g., elution time, nebulization and transport efficiency and peak broadening, versus carrier gas flow-rate have been studied. Comparisons to a previous design with the Pt electrode inserted into the end of the CE capillary are made where appropriate. The reproducibility (RSD) in ICP emission intensity of the system is <4%. Detection limits of Cr and Cu are similar to 5 ng/ml. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:139 / 148
页数:10
相关论文
共 26 条
[1]   Capillary electrophoresis and inductively coupled plasma spectrometry: Status report [J].
Barnes, RM .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (03) :246-251
[2]  
Camilleri P, 1998, CAPILLARY ELECTROPHO
[3]   Interface for capillary electrophoresis coupled with inductively coupled plasma atomic emission spectrometry [J].
Chan, YY ;
Chan, WT .
JOURNAL OF CHROMATOGRAPHY A, 1999, 853 (1-2) :141-149
[4]   Capillary electrophoresis: the state-of-the-art in metal speciation studies [J].
Dabek-Zlotorzynska, E ;
Lai, EPC ;
Timerbaev, AR .
ANALYTICA CHIMICA ACTA, 1998, 359 (1-2) :1-26
[5]   Advances in capillary electrophoresis [J].
Deyl, Z ;
Miksík, I ;
Tagliaro, F .
FORENSIC SCIENCE INTERNATIONAL, 1998, 92 (2-3) :89-124
[6]   Effect of laminar flow in capillary electrophoresis: Model and experimental results on controlling analysis time and resolution with inductively coupled plasma mass spectrometry detection [J].
Kinzer, JA ;
Olesik, JW ;
Olesik, SV .
ANALYTICAL CHEMISTRY, 1996, 68 (18) :3250-3257
[7]  
KUHN R, 1993, CAPILLARY ELECTROPHO, P111
[8]   CAPILLARY ELECTROPHORESIS COUPLED ONLINE WITH INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY FOR ELEMENTAL SPECIATION [J].
LIU, Y ;
LOPEZAVILA, V ;
ZHU, JJ ;
WIEDERIN, DR ;
BECKERT, WF .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :2020-2025
[9]   Microconcentric nebuliser for the analysis of small sample volumes by inductively coupled plasma mass spectrometry [J].
Lofthouse, SD ;
Greenway, GM ;
Stephen, SC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (12) :1373-1376
[10]   Evaluation of an ultrasonic nebulizer interface for capillary electrophoresis and inductively coupled plasma mass spectrometry [J].
Lu, QH ;
Barnes, RM .
MICROCHEMICAL JOURNAL, 1996, 54 (02) :129-143