Risk Stratification Algorithm for Management of Head-Neck Taper Tribocorrosion in Patients with Metal-on-Polyethylene Total Hip Arthroplasty Consensus Statement of the American Association of Hip and Knee Surgeons, the American Academy of Orthopaedic Surgeons, and The Hip Society

被引:13
作者
Kwon, Young-Min [1 ]
Della Valle, Craig J. [2 ]
Lombardi, Adolph V. [3 ]
Garbuz, Donald S. [4 ]
Berry, Daniel J. [5 ]
Jacobs, Joshua J. [2 ]
机构
[1] Harvard Med Sch, Massachusetts Gen Hosp, Dept Orthopaed Surg, Boston, MA 02115 USA
[2] Rush Univ, Med Ctr, Dept Orthopaed Surg, Chicago, IL 60612 USA
[3] Ohio State Univ, Joint Implant Surg Inc, New Albany, OH USA
[4] Univ British Columbia, Dept Orthopaed Surg, Vancouver, BC, Canada
[5] Mayo Clin, Dept Orthoped Surg, Rochester, MN USA
关键词
LOCAL TISSUE-REACTIONS; ION LEVELS; REACTIONS SECONDARY; TRUNNION CORROSION; DIAGNOSIS; JUNCTION; SERUM; STEM; PSEUDOTUMORS; SPECIFICITY;
D O I
10.2106/JBJS.20.01837
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Adverse local tissue reactions (ALTRs) were initially reported as complications associated with metal-on-metal (MoM) bearings; however, there is increasing concern regarding the occurrence of adverse local tissue reactions from mechanically assisted crevice corrosion (MACC) at the femoral head-neck junction or between other modular junctions of the implant containing cobalt chromium parts in patients with metal-on-polyethylene (MoP) bearings. ALTR due to MACC at the head-neck junction has primarily been reported in association with cobalt chromium alloy femoral heads. As pain following total hip arthroplasty may have various intrinsic and extrinsic causes, a systematic approach to evaluation (risk stratification algorithm) based on the currently available data is recommended to optimize patient management. Evaluation should begin by ruling out common causes of pain, including component loosening and periprosthetic joint infection. While specialized tests such as blood metal analysis and metal artifact reduction sequence magnetic resonance imaging (MARS MRI) are useful modalities in evaluating for ALTRs, over-reliance on any single investigative tool in the clinical decision-making process should be avoided. There should be a low threshold to perform a systematic evaluation for ALTR due to MACC in patients with metal-on-polyethylene total hip arthroplasty as early recognition and diagnosis is critical, as delays in appropriate treatment initiation may result in soft-tissue damage, which complicates surgical treatment and is associated with a higher risk of complications and poorer patient outcomes.
引用
收藏
页数:9
相关论文
共 66 条
[51]   A High Prevalence of Corrosion at the Head-Neck Taper with Contemporary Zimmer Non-Cemented Femoral Hip Components [J].
McGrory, Brian J. ;
MacKenzie, Johanna ;
Babikian, George .
JOURNAL OF ARTHROPLASTY, 2015, 30 (07) :1265-1268
[52]   Metal Ion Levels in Young, Active Patients Receiving a Modular, Dual Mobility Total Hip Arthroplasty [J].
Nam, Denis ;
Salih, Rondek ;
Brown, Katherine M. ;
Nunley, Ryan M. ;
Barrack, Robert L. .
JOURNAL OF ARTHROPLASTY, 2017, 32 (05) :1581-1585
[53]   MRI, Retrieval Analysis, and Histologic Evaluation of Adverse Local Tissue Reaction in Metal-on-Polyethylene Total Hip Arthroplasty [J].
Nodzo, Scott R. ;
Esposito, Christina I. ;
Potter, Hollis G. ;
Ranawat, Chitranjan S. ;
Wright, Timothy M. ;
Padgett, Douglas E. .
JOURNAL OF ARTHROPLASTY, 2017, 32 (05) :1647-1653
[54]   The Alpha-Defensin Test for Diagnosing Periprosthetic Joint Infection in the Setting of an Adverse Local Tissue Reaction Secondary to a Failed Metal-on-Metal Bearing or Corrosion at the Head-Neck Junction [J].
Okroj, Kamil T. ;
Calkins, Tyler E. ;
Kayupov, Erdan ;
Kheir, Michael M. ;
Bingham, Joshua S. ;
Beauchamp, Christopher P. ;
Parvizi, Javad ;
Della Valle, Craig J. .
JOURNAL OF ARTHROPLASTY, 2018, 33 (06) :1896-1898
[55]   Corrosion at the head-neck interface of current designs of modular femoral components ESSENTIAL QUESTIONS AND ANSWERS RELATING TO CORROSION IN MODULAR HEAD-NECK JUNCTIONS [J].
Osman, K. ;
Panagiotidou, A. P. ;
Khan, M. ;
Blunn, G. ;
Haddad, F. S. .
BONE & JOINT JOURNAL, 2016, 98B (05) :579-584
[56]   Modular Taper Junction Corrosion and Failure: How to Approach a Recalled Total Hip Arthroplasty Implant [J].
Pivec, Robert ;
Meneghini, R. Michael ;
Hozack, William J. ;
Westrich, Geoffrey H. ;
Mont, Michael A. .
JOURNAL OF ARTHROPLASTY, 2014, 29 (01) :1-6
[57]   Diagnosis and Management of Adverse Local Tissue Reactions Secondary to Corrosion at the Head-Neck Junction in Patients With Metal on Polyethylene Bearings [J].
Plummer, Darren R. ;
Berger, Richard A. ;
Paprosky, Wayne G. ;
Sporer, Scott M. ;
Jacobs, Joshua J. ;
Della Valle, Craig J. .
JOURNAL OF ARTHROPLASTY, 2016, 31 (01) :264-268
[58]   Modern Trunnions Are More Flexible: A Mechanical Analysis of THA Taper Designs [J].
Porter, David A. ;
Urban, Robert M. ;
Jacobs, Joshua J. ;
Gilbert, Jeremy L. ;
Rodriguez, Jose A. ;
Cooper, H. John .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (12) :3963-3970
[59]   Trunnion Corrosion in Metal-on Polyethylene Total Hip Arthroplasty: A Case Series [J].
Raju, Sivashanmugam ;
Chinnakkannu, Karthikeyan ;
Puttaswamy, Mohan K. ;
Phillips, Matthew J. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2017, 25 (02) :133-139
[60]   Perioperative testing for joint infection in patients undergoing revision total hip arthroplasty [J].
Schinsky, Mark F. ;
Della Valle, Craig J. ;
Sporer, Scott M. ;
Paprosky, Wayne G. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (09) :1869-1875