Risk Stratification Algorithm for Management of Head-Neck Taper Tribocorrosion in Patients with Metal-on-Polyethylene Total Hip Arthroplasty Consensus Statement of the American Association of Hip and Knee Surgeons, the American Academy of Orthopaedic Surgeons, and The Hip Society

被引:12
作者
Kwon, Young-Min [1 ]
Della Valle, Craig J. [2 ]
Lombardi, Adolph V. [3 ]
Garbuz, Donald S. [4 ]
Berry, Daniel J. [5 ]
Jacobs, Joshua J. [2 ]
机构
[1] Harvard Med Sch, Massachusetts Gen Hosp, Dept Orthopaed Surg, Boston, MA 02115 USA
[2] Rush Univ, Med Ctr, Dept Orthopaed Surg, Chicago, IL 60612 USA
[3] Ohio State Univ, Joint Implant Surg Inc, New Albany, OH USA
[4] Univ British Columbia, Dept Orthopaed Surg, Vancouver, BC, Canada
[5] Mayo Clin, Dept Orthoped Surg, Rochester, MN USA
关键词
LOCAL TISSUE-REACTIONS; ION LEVELS; REACTIONS SECONDARY; TRUNNION CORROSION; DIAGNOSIS; JUNCTION; SERUM; STEM; PSEUDOTUMORS; SPECIFICITY;
D O I
10.2106/JBJS.20.01837
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Adverse local tissue reactions (ALTRs) were initially reported as complications associated with metal-on-metal (MoM) bearings; however, there is increasing concern regarding the occurrence of adverse local tissue reactions from mechanically assisted crevice corrosion (MACC) at the femoral head-neck junction or between other modular junctions of the implant containing cobalt chromium parts in patients with metal-on-polyethylene (MoP) bearings. ALTR due to MACC at the head-neck junction has primarily been reported in association with cobalt chromium alloy femoral heads. As pain following total hip arthroplasty may have various intrinsic and extrinsic causes, a systematic approach to evaluation (risk stratification algorithm) based on the currently available data is recommended to optimize patient management. Evaluation should begin by ruling out common causes of pain, including component loosening and periprosthetic joint infection. While specialized tests such as blood metal analysis and metal artifact reduction sequence magnetic resonance imaging (MARS MRI) are useful modalities in evaluating for ALTRs, over-reliance on any single investigative tool in the clinical decision-making process should be avoided. There should be a low threshold to perform a systematic evaluation for ALTR due to MACC in patients with metal-on-polyethylene total hip arthroplasty as early recognition and diagnosis is critical, as delays in appropriate treatment initiation may result in soft-tissue damage, which complicates surgical treatment and is associated with a higher risk of complications and poorer patient outcomes.
引用
收藏
页数:9
相关论文
共 66 条
  • [1] Short-Term Outcomes and Complications After Rejuvenate Modular Total Hip Arthroplasty Revision
    Barlow, Brian T.
    Boles, John W.
    Lee, Yuo-yu
    Ortiz, Philippe A.
    Westrich, Geoffrey H.
    [J]. JOURNAL OF ARTHROPLASTY, 2016, 31 (04) : 857 - 862
  • [2] Advanced MRI Techniques for the Hip Joint: Focus on the Postoperative Hip
    Berkowitz, Jennifer L.
    Potter, Hollis G.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 209 (03) : 534 - 543
  • [3] Trunnion corrosion WHAT SURGEONS NEED TO KNOW IN 2018
    Berstock, J. R.
    Whitehouse, M. R.
    Duncan, C. P.
    [J]. BONE & JOINT JOURNAL, 2018, 100B (01) : 44 - 49
  • [4] Outcome of Re-Revision Surgery for Adverse Local Tissue Reaction in Metal-on-Polyethylene and Metal-on-Metal Total Hip Arthroplasty
    Bonner, Bryant
    Arauz, Paul
    Klemt, Christian
    Kwon, Young-Min
    [J]. JOURNAL OF ARTHROPLASTY, 2020, 35 (06) : S284 - S288
  • [5] MR Imaging of Adverse Local Tissue Reactions around Rejuvenate Modular Dual-Taper Stems
    Burge, Alissa J.
    Gold, Stephanie L.
    Lurie, Brett
    Nawabi, Danyal H.
    Fields, Kara G.
    Koff, Matthew F.
    Westrich, Geoffrey
    Potter, Hollis G.
    [J]. RADIOLOGY, 2015, 277 (01) : 142 - 150
  • [6] Carothers Joshua T, 2015, Am J Orthop (Belle Mead NJ), V44, P411
  • [7] Pseudotumour Formation Due to Tribocorrosion at the Taper Interface of Large Diameter Metal on Polymer Modular Total Hip Replacements
    Cook, Richard B.
    Bolland, Benjamin J. R. F.
    Wharton, Julian A.
    Tilley, Simon
    Latham, Jeremy M.
    Wood, Robert J. K.
    [J]. JOURNAL OF ARTHROPLASTY, 2013, 28 (08) : 1430 - 1436
  • [8] Adverse Local Tissue Reaction Arising from Corrosion at the Femoral Neck-Body Junction in a Dual-Taper Stem with a Cobalt-Chromium Modular Neck
    Cooper, H. John
    Urban, Robert M.
    Wixson, Richard L.
    Meneghini, R. Michael
    Jacobs, Joshua J.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (10) : 865 - 872
  • [9] Corrosion at the Head-Neck Taper as a Cause for Adverse Local Tissue Reactions After Total Hip Arthroplasty
    Cooper, H. John
    Della Valle, Craig J.
    Berger, Richard A.
    Tetreault, Matthew
    Paprosky, Wayne G.
    Sporer, Scott M.
    Jacobs, Joshua J.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (18) : 1655 - 1661
  • [10] Diagnosis and Treatment of Adverse Local Tissue Reactions at the Head-Neck Junction
    Cooper, Herbert J.
    [J]. JOURNAL OF ARTHROPLASTY, 2016, 31 (07) : 1381 - 1384