Sparse precontrast T1 mapping for high-resolution whole-brain DCE-MRI

被引:3
作者
Zhu, Zhibo [1 ]
Lebel, R. Marc [2 ,3 ]
Bliesener, Yannick [1 ]
Acharya, Jay [4 ]
Frayne, Richard [3 ,5 ]
Nayak, Krishna S. [1 ,4 ]
机构
[1] Univ Southern Calif, Ming Hsieh Dept Elect & Comp Engn, 3740 McClintock Ave,EEB 412, Los Angeles, CA 90089 USA
[2] Gen Elect Healthcare, Calgary, AB, Canada
[3] Univ Calgary, Hotchkiss Brain Inst, Radiol & Clin Neurosci, Calgary, AB, Canada
[4] Univ Southern Calif, Dept Radiol, Los Angeles, CA 90089 USA
[5] Foothills Med Ctr, Seaman Family MR Res Ctr, Calgary, AB, Canada
基金
美国国家卫生研究院;
关键词
brain tumor; model-based reconstruction; quantitative dynamic contrast-enhanced-magnetic resonance imaging (DCE-MRI); sparse sampling; T-1; mapping; CONTRAST-ENHANCED MRI; ARTERIAL INPUT FUNCTION; VARIABLE FLIP ANGLE; MULTIPLE-SCLEROSIS; KINETIC-PARAMETERS; PERMEABILITY; TRACER; T1; GLIOMA; MODEL;
D O I
10.1002/mrm.28849
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop and evaluate an efficient precontrast T-1 mapping technique suitable for quantitative high-resolution whole-brain dynamic contrast-enhanced-magnetic resonance imaging (DCE-MRI). Methods: Variable flip angle (VFA) T-1 mapping was considered that provides 1 x 1 x 2 mm(3) resolution to match a recent high-resolution whole-brain DCE-MRI protocol. Seven FAs were logarithmically spaced from 1.5 degrees to 15 degrees. T-1 and M-0 maps were estimated using model-based reconstruction. This approach was evaluated using an anatomically realistic brain tumor digital reference object (DRO) with noise-mimicking 3T neuroimaging and fully sampled data acquired from one healthy volunteer. Methods were also applied on fourfold prospectively undersampled VFA data from 13 patients with high-grade gliomas. Results: T-1-mapping precision decreased with undersampling factor R, althoughwhereas bias remained small before a critical R. In the noiseless DRO, T-1 bias was <25 ms in white matter (WM) and <11 ms in brain tumor (BT). T-1 standard deviation (SD) was <119.5 ms in WM (coefficient of variation [COV] similar to 11.0%) and <253.2 ms in BT (COV similar to 12.7%). In the noisy DRO, T-1 bias was <50 ms in WM and <30 ms in BT. For R <= 10, T-1 SD was <107.1 ms in WM (COV similar to 9.9%) and <240.9 ms in BT (COV similar to 12.1%). In the healthy subject, T-1 bias was <30 ms for R <= 16. At R = 4, T-1 SD was 171.4 ms (COV similar to 13.0%). In the prospective brain tumor study, T-1 values were consistent with literature values in WM and BT. Conclusion: High-resolution whole-brain VFA T-1 mapping is feasible with sparse sampling, supporting its use for quantitative DCE-MRI.
引用
收藏
页码:2234 / 2249
页数:16
相关论文
共 43 条
  • [1] MR Fingerprinting of Adult Brain Tumors: Initial Experience
    Badve, C.
    Yu, A.
    Dastmalchian, S.
    Rogers, M.
    Ma, D.
    Jiang, Y.
    Margevicius, S.
    Pahwa, S.
    Lu, Z.
    Schluchter, M.
    Sunshine, J.
    Griswold, M.
    Sloan, A.
    Gulani, V.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (03) : 492 - 499
  • [2] Impact of (k,t) sampling on DCE MRI tracer kinetic parameter estimation in digital reference objects
    Bliesener, Yannick
    Lingala, Sajan G.
    Haldar, Justin P.
    Nayak, Krishna S.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (05) : 1625 - 1639
  • [3] Creating an anthropomorphic digital MR phantom-an extensible tool for comparing and evaluating quantitative imaging algorithms
    Bosca, Ryan J.
    Jackson, Edward F.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (02) : 974 - 982
  • [4] Rapid high-resolution T1 mapping by variable flip angles:: Accurate and precise measurements in the presence of radiofrequency field inhomogeneity
    Cheng, HLM
    Wright, GA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (03) : 566 - 574
  • [5] Abnormal blood-brain barrier permeability in normal appearing white matter in multiple sclerosis investigated by MRI
    Cramer, S. P.
    Simonsen, H.
    Frederiksen, J. L.
    Rostrup, E.
    Larsson, H. B. W.
    [J]. NEUROIMAGE-CLINICAL, 2014, 4 : 182 - 189
  • [6] Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state
    Deoni, SCL
    Rutt, BK
    Peters, TM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (03) : 515 - 526
  • [7] High-resolution T1 mapping of the brain at 3T with driven equilibrium single pulse observation of T1 with high-speed incorporation of RF field inhomogeneities (DESPOT1-HIFI)
    Deoni, Sean C. L.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (04) : 1106 - 1111
  • [8] Improved Accuracy and Precision of Tracer Kinetic Parameters by Joint Fitting to Variable Flip Angle and Dynamic Contrast Enhanced MRI Data
    Dickie, Ben R.
    Banerji, Anita
    Kershaw, Lucy E.
    McPartlin, Andrew
    Choudhury, Ananya
    West, Catharine M.
    Rose, Chris J.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (04) : 1270 - 1281
  • [9] Practical considerations in T1 mapping of prostate for dynamic contrast enhancement pharmacokinetic analyses
    Fennessy, Fiona M.
    Fedorov, Andriy
    Gupta, Sandeep N.
    Schmidt, Ehud J.
    Tempany, Clare M.
    Mulkern, Robert V.
    [J]. MAGNETIC RESONANCE IMAGING, 2012, 30 (09) : 1224 - 1233
  • [10] RAPID CALCULATION OF T1 USING VARIABLE FLIP ANGLE GRADIENT REFOCUSED IMAGING
    FRAM, EK
    HERFKENS, RJ
    JOHNSON, GA
    GLOVER, GH
    KARIS, JP
    SHIMAKAWA, A
    PERKINS, TG
    PELC, NJ
    [J]. MAGNETIC RESONANCE IMAGING, 1987, 5 (03) : 201 - 208