The Study of Single-phase PWM Rectifier Based on PR Control Strategy

被引:0
作者
Wang Helin [1 ]
Cheng Qiming [1 ]
Li Ming [1 ]
Chen Gen [1 ]
Deng Liang [1 ]
机构
[1] Shanghai Univ Elect Power, Coll Automat Engn, Shanghai 200090, Peoples R China
来源
26TH CHINESE CONTROL AND DECISION CONFERENCE (2014 CCDC) | 2014年
关键词
Single-phase rectifiers; CHC control; PR-based control; STEADY-STATE ERROR; INVERTERS; FILTERS;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Synchronous PI controller is usually used to track current in three-phase PWM rectifier with zero steady-state error which is difficult to achieve in the single-phase system. A novel proportional-resonant (PR) control scheme for single-phase PWM rectifier is proposed in the paper. Compared with traditional PI control and current hystereis control (CHC) methods, the PR control structure is simple and can reduce control time delay significantly. The simulation results verify the feasibility of the proposed control scheme in the disturbance rejection. In addition, sinusoidal current zero static error control can be achieved without a coordinate transformation and the DC voltage can automatically adjust to changes of grid voltage, load value and frequency which contributes to energy conversion and bidirectional flow of electricity.
引用
收藏
页码:3818 / 3823
页数:6
相关论文
共 25 条
  • [11] Jiabing H, 2011, DFIG WIND GENERATION, V36, P829
  • [12] Jiang Jun-feng, 2004, Proceedings of the CSEE, V24, P82
  • [13] JUNG E, 2009, P APPL POW EL C EXP, P889
  • [14] A novel DSP-based current-controlled PWM strategy for single phase grid connected inverters
    Kojabadi, Hossein Madadi
    Yu, Bin
    Gadoura, Idris A.
    Chang, Liuchen
    Ghribi, Mohsen
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2006, 21 (04) : 985 - 993
  • [15] LI Li, 2010, POWER SYSTEM PROTECT, V38, P76
  • [16] Control strategies for single-phase grid integration of small-scale renewable energy sources: A review
    Monfared, Mohammad
    Golestan, Saeed
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (07) : 4982 - 4993
  • [17] OUYANG Honglin, 2005, J HUNAN U, V32, P93
  • [18] Instantaneous phase-angle estimation algorithm under unbalanced voltage-sag conditions
    Song, HS
    Nam, K
    [J]. IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2000, 147 (06) : 409 - 415
  • [19] Line-interactive UPS using a fuel cell as the primary source
    Tao, Haimin
    Duarte, Jorge L.
    Hendrix, Marcel A. M.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (08) : 3012 - 3021
  • [20] Yu B, 2005, IEEE POWER ELECTRON, P231