Electrochemical sensor for simultaneous determination of ascorbic acid, uric acid and folic acid based on Mn-SnO2 nanoparticles modified glassy carbon electrode

被引:97
作者
Lavanya, N. [1 ,3 ]
Fazio, E. [2 ]
Neri, F. [2 ]
Bonavita, A. [3 ]
Leonardi, S. G. [3 ]
Neri, G. [3 ]
Sekar, C. [1 ]
机构
[1] Alagappa Univ, Dept Bioelect & Biosensors, Karaikkudi 630003, Tamil Nadu, India
[2] Univ Messina, Dept Phys & Earth Phys, I-98166 Messina, Italy
[3] Univ Messina, Dept Elect Engn, Chem & Mat Engn, I-98166 Messina, Italy
关键词
Electrochemical sensor; Ascorbic add; Uric acid; Folic acid; Mn doped SnO2 nanoparticles; Simultaneous determination; MN-DOPED SNO2; ROOM-TEMPERATURE FERROMAGNETISM; VOLTAMMETRIC DETERMINATION; SELECTIVE DETERMINATION; MAGNETIC-PROPERTIES; PASTE ELECTRODE; BIOSENSOR; DOPAMINE; FABRICATION; POWDERS;
D O I
10.1016/j.jelechem.2016.03.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly sensitive and selective electrochemical sensor was fabricated based on Mn doped SnO2 nanoparticles (NPs) modified glassy carbon electrode (Mn-SnO2/GCE) for simultaneous determination of ascorbic acid (AA), uric add (UA) and folic acid (FA) for the first time. The Mn-SnO2 NPs synthesized by microwave irradiation method were characterized using X-ray diffraction (XRD), transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS), vibrating sample magnetometer (VSM), electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and square wave voltammetry (SWV) techniques. The Mn-SnO2/GCE exhibited excellent electrocatalytic activity towards the oxidations of AA, UA and FA in phosphate buffer solution (pH 6.0) and the corresponding electrochemical signals have appeared as three well resolved oxidation peaks with significant peak potential differences of 0.141 V (AA-UA), 0.345 V (UA-FA) and 0.486 V (AA-FA). For selective determination, the linear responses of AA, UA and FA were in the concentration ranges of 1 to 900, 1 to 860 and 0.5 to 900 mu M for AA, UA and FA with detection limits of 56,36 and 79 nM respectively. For simultaneous determination by synchronous change of the analyte concentrations, the linear response ranges were between 5 and 500 mu M for UA and 1-500 mu M for FA with the lowest detection limits of 25 and 38 nM respectively in the presence of AA. The proposed sensor was proved to be applicable for the determination of the target analytes in pharmaceuticals and urine samples. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:23 / 32
页数:10
相关论文
共 25 条
[1]   Room-temperature ferromagnetism in pure and Mn doped SnO2 powders [J].
Ahmed, S. A. .
SOLID STATE COMMUNICATIONS, 2010, 150 (43-44) :2190-2193
[2]   Electrospun zinc oxide nanofibers for direct selective electrochemical detection of biological compounds [J].
Arvand, Majid ;
Tajyani, Sepideh .
RSC ADVANCES, 2015, 5 (10) :7222-7231
[3]   Structural, optical, and magnetic properties of Co-doped SnO2 powders synthesized by the coprecipitation technique [J].
Bouaine, A. ;
Brihi, N. ;
Schmerber, G. ;
Ulhaq-Bouillet, C. ;
Colis, S. ;
Dinia, A. .
JOURNAL OF PHYSICAL CHEMISTRY C, 2007, 111 (07) :2924-2928
[4]   Simultaneous electrochemical determination of dopamine, uric acid and ascorbic acid using palladium nanoparticle-loaded carbon nanofibers modified electrode [J].
Huang, Jianshe ;
Liu, Yang ;
Hou, Haoqing ;
You, Tianyan .
BIOSENSORS & BIOELECTRONICS, 2008, 24 (04) :632-637
[5]   A pre-anodized inlaying ultrathin carbon paste electrode for simultaneous determination of uric acid and folic acid [J].
Huo, Jing'e ;
Shangguan, Enbo ;
Li, Quanmin .
ELECTROCHIMICA ACTA, 2013, 89 :600-606
[6]   Sensitive electrochemical sensors for simultaneous determination of ascorbic acid, dopamine, and uric acid based on Au@Pd-reduced graphene oxide nanocomposites [J].
Jiang, Jingjing ;
Du, Xuezhong .
NANOSCALE, 2014, 6 (19) :11303-11309
[7]   Selective electrochemical sensor for folic acid at physiological pH using ultrathin electropolymerized film of functionalized thiadiazole modified glassy carbon electrode [J].
Kalimuthu, Palraj ;
John, S. Abraham .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (12) :3575-3580
[8]   Electrochemical determination of uric acid in the presence of ascorbic acid on electrochemically reduced graphene oxide modified electrode [J].
Khan, Md. Mohibul Islam ;
Hague, Al-Monsur Jiaul ;
Kim, Kyuwon .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 700 :54-59
[9]   Rutile-type oxide-diluted magnetic semiconductor:: Mn-doped SnO2 [J].
Kimura, H ;
Fukumura, T ;
Kawasaki, M ;
Inaba, K ;
Hasegawa, T ;
Koinuma, H .
APPLIED PHYSICS LETTERS, 2002, 80 (01) :94-96
[10]   Electrochemical selective determination of ascorbic acid at redox active polymer modified electrode derived from direct blue 71 [J].
Kumar, S. Ashok ;
Lo, Po-Hsun ;
Chen, Shen-Ming .
BIOSENSORS & BIOELECTRONICS, 2008, 24 (04) :518-523