Comparison of residual shunt rate and complications across 6 different closure devices for patent foramen ovale

被引:27
作者
Fleming, Rubine Gevorgyan [1 ]
Kumar, Preetham [1 ]
West, Brian [1 ]
Noureddin, Nabil [2 ]
Rusheen, Joshua [3 ]
Aboulhosn, Jamil [1 ]
Tobis, Jonathan M. [1 ]
机构
[1] Univ Calif Los Angeles, Dept Med, Div Cardiol, Los Angeles, CA 90024 USA
[2] Univ Nevada, Dept Internal Med, Las Vegas, NV 89154 USA
[3] Univ Calif Los Angeles, David Geffen Sch Med, Los Angeles, CA 90095 USA
关键词
complications; patent foramen ovale; patent foramen ovale closure; PFO closure device; residual shunt rate; MEDICAL THERAPY; IMPACT; METAANALYSIS; DIAGNOSIS; DOPPLER; DISEASE; STROKE;
D O I
10.1002/ccd.28527
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives To compare residual shunt rate and complications associated with six different devices used for PFO closure. Background Transcutaneous PFO closure is an effective treatment for preventing recurrent stroke in patients with a history of cryptogenic stroke. The rate of residual shunt is one metric by which the technical success of PFO closure can be measured. Methods Patients who underwent PFO closure at a single center between February 2001 and July 2019 were retrospectively enrolled in the study. Right-to-left shunt at baseline and during follow-up was assessed using transcranial Doppler (TCD) or transthoracic echocardiography (TTE). Periprocedural and device-related complications, including atrial fibrillation, were also assessed. Results Of 467 PFO closures performed during this period, 320 patients received quantitative assessment of right-to-left shunting both before and after percutaneous closure. The highest effective closure was achieved with the Cardioform device (100%, n = 104), followed by the Amplatzer Cribriform (93%, n = 14), Helex (90%, n = 137), Amplatzer ASO (88%, n = 17), CardioSEAL (86%, n = 14), and Amplatzer PFO (85%, n = 33) devices. The most common significant adverse event was atrial fibrillation, which was more common with the Cardioform device (13%) than the Helex (4%) or the Amplatzer PFO (4%) devices. Conclusions The Gore Cardioform Septal Occluder provides more robust closure of a PFO when compared to other devices but its effectiveness is offset by the higher prevalence of transient atrial fibrillation.
引用
收藏
页码:365 / 372
页数:8
相关论文
共 26 条
[1]   Meta-Analysis of Transcatheter Closure Versus Medical Therapy for Patent Foramen Ovale in Prevention of Recurrent Neurological Events After Presumed Paradoxical Embolism [J].
Agarwal, Shikhar ;
Bajaj, Navkaranbir Singh ;
Kumbhani, Dharam J. ;
Tuzcu, E. Murat ;
Kapadia, Samir R. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (07) :777-789
[2]   Practice Standards for Transcranial Doppler (TCD) Ultrasound. Part II. Clinical Indications and Expected Outcomes [J].
Alexandrov, Andrei V. ;
Sloan, Michael A. ;
Tegeler, Charles H. ;
Newell, David N. ;
Lumsden, Alan ;
Garami, Zsolt ;
Levy, Christopher R. ;
Wong, Lawrence K. S. ;
Douville, Colleen ;
Kaps, Manfred ;
Tsivgoulis, Georgios .
JOURNAL OF NEUROIMAGING, 2012, 22 (03) :215-224
[3]   Patent Foramen ovale and high-altitude pulmonary edema [J].
Allemann, Yves ;
Hutter, Damian ;
Lipp, Ernst ;
Sartori, Claudio ;
Duplain, Herve ;
Egli, Marc ;
Cook, Stephane ;
Scherrer, Urs ;
Seiler, Christian .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 296 (24) :2954-2958
[4]   Incidence of thrombus formation on the CardioSEAL and the Amplatzer interatrial closure devices [J].
Anzai, H ;
Child, J ;
Natterson, B ;
Krivokapich, J ;
Fishbein, MC ;
Chan, VK ;
Tobis, JM .
AMERICAN JOURNAL OF CARDIOLOGY, 2004, 93 (04) :426-431
[5]   Patent foramen ovale closure in recreational divers: effect on decompression illness and ischaemic brain lesions during long-term follow-up [J].
Billinger, Michael ;
Zbinden, Rainer ;
Mordasini, Raffaela ;
Windecker, Stephan ;
Schwerzmann, Markus ;
Meier, Bernhard ;
Seiler, Christian .
HEART, 2011, 97 (23) :1932-1937
[6]   Closure of Patent Foramen Ovale versus Medical Therapy after Cryptogenic Stroke [J].
Carroll, John D. ;
Saver, Jeffrey L. ;
Thaler, David E. ;
Smalling, Richard W. ;
Berry, Scott ;
MacDonald, Lee A. ;
Marks, David S. ;
Tirschwell, David L. .
NEW ENGLAND JOURNAL OF MEDICINE, 2013, 368 (12) :1092-1100
[7]   Patent foramen ovale, stroke, and cardiovascular disease in migraine [J].
Diener, Hans-Christoph ;
Kurth, Tobias ;
Dodick, David .
CURRENT OPINION IN NEUROLOGY, 2007, 20 (03) :310-319
[8]   Interatrial septal mobility predicts larger shunts across patent foramen ovales: An analysis with transmitral Doppler scanning [J].
Fox, ER ;
Picard, MH ;
Chow, CM ;
Levine, RA ;
Schwamm, L ;
Kerr, AJ .
AMERICAN HEART JOURNAL, 2003, 145 (04) :730-736
[9]  
Goel SS, 2013, TEX HEART I J, V40, P439
[10]   INCIDENCE AND SIZE OF PATENT FORAMEN OVALE DURING THE 1ST 10 DECADES OF LIFE - AN AUTOPSY STUDY OF 965 NORMAL HEARTS [J].
HAGEN, PT ;
SCHOLZ, DG ;
EDWARDS, WD .
MAYO CLINIC PROCEEDINGS, 1984, 59 (01) :17-20